Literature DB >> 10195011

Radiation exposure to medical staff in interventional and cardiac radiology.

E Vañó1, L González, E Guibelalde, J M Fernández, J I Ten.   

Abstract

The aim of this work has been to determine typical occupational dose levels in interventional radiology and cardiology installations and to relate doses to patient and occupational dosimetry through the dose-area product. An experimental correlation between environmental dosimetric records and dose-area products in the centres studied was established. The study covered a sample of 83 procedures performed by 10 specialists in six laboratories. The radiologists and cardiologists monitored wore nine thermoluminescent chips next to eyes, forehead, neck, hands, left shoulder, left forearm and left arm during each single procedure. In addition, direct reading electronic devices for environmental dosimetry were placed in the C-arm of the X-ray system, to estimate roughly the occupational radiation risk level. Typical shoulder doses derived from electronic dosimetry range between 300 and 500 muSv per procedure, assuming no lead protective screens were used. Using these values and patient dose-area data from two laboratories, averaged ratios of 84 and 120 muSv per 1000 cGy cm2 are obtained for cardiology procedures. Finally, occupational dose reductions of approximately 20% when using highly filtered X-ray beams with automatic tube potential (kV) reduction (available in some facilities), and by a factor of about three when using ceiling mounted screens, have been found.

Entities:  

Mesh:

Year:  1998        PMID: 10195011     DOI: 10.1259/bjr.71.849.10195011

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  42 in total

1.  What are the implications of the proposed revision of the eye dose limit for interventional operators?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2011-10       Impact factor: 3.039

2.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures.

Authors:  E P Efstathopoulos; I Pantos; M Andreou; A Gkatzis; E Carinou; C Koukorava; N L Kelekis; E Brountzos
Journal:  Br J Radiol       Date:  2011-01       Impact factor: 3.039

Review 3.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

Review 4.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

5.  Sex proportion of offspring and exposure to radiation in male invasive cardiologists.

Authors:  James W Choi; Praveen Mehrotra; Lee A Macdonald; Lloyd W Klein; Norm M Linsky; Anne M Smith; Mark J Ricciardi
Journal:  Proc (Bayl Univ Med Cent)       Date:  2007-07

6.  Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study.

Authors:  Uwe Häusler; Renate Czarwinski; Gunnar Brix
Journal:  Eur Radiol       Date:  2009-04-07       Impact factor: 5.315

7.  Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters.

Authors:  T Moritake; Y Matsumaru; T Takigawa; K Nishizawa; A Matsumura; K Tsuboi
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-21       Impact factor: 3.825

Review 8.  Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review.

Authors:  Kwang Pyo Kim; Donald L Miller
Journal:  Radiat Prot Dosimetry       Date:  2009-03-27       Impact factor: 0.972

9.  Radiation exposure to cardiologists: how it could be reduced.

Authors:  E Vano
Journal:  Heart       Date:  2003-10       Impact factor: 5.994

Review 10.  [Occupational exposure to radiation].

Authors:  M Wucherer; R Loose
Journal:  Radiologe       Date:  2005-03       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.