Literature DB >> 16193773

Computer-aided detection of lung nodules: false positive reduction using a 3D gradient field method and 3D ellipsoid fitting.

Zhanyu Ge1, Berkman Sahiner, Heang-Ping Chan, Lubomir M Hadjiiski, Philip N Cascade, Naama Bogot, Ella A Kazerooni, Jun Wei, Chuan Zhou.   

Abstract

We are developing a computer-aided detection system to assist radiologists in the detection of lung nodules on thoracic computed tomography (CT) images. The purpose of this study was to improve the false-positive (FP) reduction stage of our algorithm by developing features that extract three-dimensional (3D) shape information from volumes of interest identified in the prescreening stage. We formulated 3D gradient field descriptors, and derived 19 gradient field features from their statistics. Six ellipsoid features were obtained by computing the lengths and the length ratios of the principal axes of an ellipsoid fitted to a segmented object. Both the gradient field features and the ellipsoid features were designed to distinguish spherical objects such as lung nodules from elongated objects such as vessels. The FP reduction performance in this new 25-dimensional feature space was compared to the performance in a 19-dimensional space that consisted of features extracted using previously developed methods. The performance in the 44-dimensional combined feature space was also evaluated. Linear discriminant analysis with stepwise feature selection was used for classification. The parameters used for feature selection were optimized using the simplex algorithm. Training and testing were performed using a leave-one-patient-out scheme. The FP reduction performances in different feature spaces were evaluated by using the area Az under the receiver operating characteristic curve and the number of FPs per CT section at a given sensitivity as accuracy measures. Our data set consisted of 82 CT scans (3551 axial sections) from 56 patients with section thickness ranging from 1.0 to 2.5 mm. Our prescreening algorithm detected 111 of the 116 solid nodules (nodule size: 3.0-30.6 mm) marked by experienced thoracic radiologists. The test Az values were 0.95 +/- 0.01, 0.88 +/- 0.02, and 0.94 +/- 0.01 in the new, previous, and combined feature spaces, respectively. The number of FPs per section at 80% sensitivity in these three feature spaces were 0.37, 1.61, and 0.34, respectively. The improvement in the test Az with the 25 new features was statistically significant (p<0.0001) compared to that with the previous 19 features alone.

Entities:  

Mesh:

Year:  2005        PMID: 16193773      PMCID: PMC2800987          DOI: 10.1118/1.1944667

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  A pattern classification approach to characterizing solitary pulmonary nodules imaged on high resolution CT: preliminary results.

Authors:  M F McNitt-Gray; E M Hart; N Wyckoff; J W Sayre; J G Goldin; D R Aberle
Journal:  Med Phys       Date:  1999-06       Impact factor: 4.071

2.  Automated detection of pulmonary nodules in helical CT images based on an improved template-matching technique.

Authors:  Y Lee; T Hara; H Fujita; S Itoh; T Ishigaki
Journal:  IEEE Trans Med Imaging       Date:  2001-07       Impact factor: 10.048

3.  Automated detection of lung nodules in CT scans: preliminary results.

Authors:  S G Armato; M L Giger; H MacMahon
Journal:  Med Phys       Date:  2001-08       Impact factor: 4.071

4.  Lung cancer: performance of automated lung nodule detection applied to cancers missed in a CT screening program.

Authors:  Samuel G Armato; Feng Li; Maryellen L Giger; Heber MacMahon; Shusuke Sone; Kunio Doi
Journal:  Radiology       Date:  2002-12       Impact factor: 11.105

5.  Lung micronodules: automated method for detection at thin-section CT--initial experience.

Authors:  Matthew S Brown; Jonathan G Goldin; Robert D Suh; Michael F McNitt-Gray; James W Sayre; Denise R Aberle
Journal:  Radiology       Date:  2003-01       Impact factor: 11.105

6.  Estimation of dynamically evolving ellipsoids with applications to medical imaging.

Authors:  S Jaggi; W C Karl; A S Willsky
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

7.  Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans.

Authors:  Qiang Li; Shusuke Sone; Kunio Doi
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

8.  Determining the likelihood of malignancy in solitary pulmonary nodules with Bayesian analysis. Part I. Theory.

Authors:  J W Gurney
Journal:  Radiology       Date:  1993-02       Impact factor: 11.105

9.  High-resolution CT of the lung: determination of the usefulness of CT scans obtained with the patient prone based on plain radiographic findings.

Authors:  J Volpe; M L Storto; K Lee; W R Webb
Journal:  AJR Am J Roentgenol       Date:  1997-08       Impact factor: 3.959

10.  Automated detection of polyps with CT colonography: evaluation of volumetric features for reduction of false-positive findings.

Authors:  Janne Näppi; Hiroyuki Yoshida
Journal:  Acad Radiol       Date:  2002-04       Impact factor: 3.173

View more
  24 in total

1.  Content-based image-retrieval system in chest computed tomography for a solitary pulmonary nodule: method and preliminary experiments.

Authors:  Masahiro Endo; Takeshi Aramaki; Koiku Asakura; Michihisa Moriguchi; Masahiro Akimaru; Akira Osawa; Ryuji Hisanaga; Yoshiyuki Moriya; Kazuo Shimura; Hiroyoshi Furukawa; Ken Yamaguchi
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-01-19       Impact factor: 2.924

Review 2.  Recent progress in computer-aided diagnosis of lung nodules on thin-section CT.

Authors:  Qiang Li
Journal:  Comput Med Imaging Graph       Date:  2007-03-21       Impact factor: 4.790

3.  Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: a phantom study.

Authors:  Ted W Way; Heang-Ping Chan; Mitchell M Goodsitt; Berkman Sahiner; Lubomir M Hadjiiski; Chuan Zhou; Aamer Chughtai
Journal:  Phys Med Biol       Date:  2008-02-13       Impact factor: 3.609

4.  Pulmonary nodule registration in serial CT scans based on rib anatomy and nodule template matching.

Authors:  Jiazheng Shi; Berkman Sahiner; Heang-Ping Chan; Lubomir Hadjiiski; Chuan Zhou; Philip N Cascade; Naama Bogot; Ella A Kazerooni; Yi-Ta Wu; Jun Wei
Journal:  Med Phys       Date:  2007-04       Impact factor: 4.071

5.  Computerized detection of lung nodules in thin-section CT images by use of selective enhancement filters and an automated rule-based classifier.

Authors:  Qiang Li; Feng Li; Kunio Doi
Journal:  Acad Radiol       Date:  2008-02       Impact factor: 3.173

Review 6.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM.

Authors:  Maryellen L Giger; Heang-Ping Chan; John Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

7.  High performance lung nodule detection schemes in CT using local and global information.

Authors:  Wei Guo; Qiang Li
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

Review 8.  Computer-aided diagnosis of lung cancer and pulmonary embolism in computed tomography-a review.

Authors:  Heang-Ping Chan; Lubomir Hadjiiski; Chuan Zhou; Berkman Sahiner
Journal:  Acad Radiol       Date:  2008-05       Impact factor: 3.173

9.  Computer-aided diagnosis of pulmonary nodules on CT scans: improvement of classification performance with nodule surface features.

Authors:  Ted W Way; Berkman Sahiner; Heang-Ping Chan; Lubomir Hadjiiski; Philip N Cascade; Aamer Chughtai; Naama Bogot; Ella Kazerooni
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

10.  A review of computer-aided diagnosis in thoracic and colonic imaging.

Authors:  Kenji Suzuki
Journal:  Quant Imaging Med Surg       Date:  2012-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.