Literature DB >> 22894441

High performance lung nodule detection schemes in CT using local and global information.

Wei Guo1, Qiang Li.   

Abstract

PURPOSE: A key issue in current computer-aided diagnostic (CAD) schemes for nodule detection in CT is the large number of false positives, because current schemes use only global three-dimensional (3D) information to detect nodules and discard useful local two-dimensional (2D) information. Thus, the authors integrated local and global information to markedly improve the performance levels of CAD schemes.
METHODS: Our database was obtained from the standard CT lung nodule database created by the Lung Image Database Consortium (LIDC). It consisted of 85 CT scans with 111 nodules of 3 mm or larger in diameter. The 111 nodules were confirmed by at least two of the four radiologists participated in the LIDC. Twenty-six nodules were missed by two of the four radiologists and were thus very difficult to detect. The authors developed five CAD schemes for nodule detection in CT using global 3D information (3D scheme), local 2D information (2D scheme), and both local and global information (2D + 3D scheme, 2D - 3D scheme, and 3D - 2D scheme). The 3D scheme, which was developed previously, used only global 3D information and discarded local 2D information, as other CAD schemes did. The 2D scheme used a uniform viewpoint reformation technique to decompose a 3D nodule candidate into a set of 2D reformatted images generated from representative viewpoints, and selected and used "effective" 2D reformatted images to remove false positives. The 2D + 3D scheme, 2D - 3D scheme, and 3D - 2D scheme used complementary local and global information in different ways to further improve the performance of lung nodule detection. The authors employed a leave-one-scan-out testing method for evaluation of the performance levels of the five CAD schemes.
RESULTS: At the sensitivities of 85%, 80%, and 75%, the existing 3D scheme reported 17.3, 7.4, and 2.8 false positives per scan, respectively; the 2D scheme improved the detection performance and reduced the numbers of false positives to 7.6, 2.5, and 1.3 per scan; the 2D + 3D scheme further reduced those to 2.7, 1.9, and 0.6 per scan; the 2D - 3D scheme reduced those to 7.6, 2.1, and 0.8 per scan; and the 3D - 2D scheme reduced those to 17.3, 1.6, and 1.0 per scan.
CONCLUSIONS: The local 2D information appears to be more useful than the global 3D information for nodule detection, particularly, when it is integrated with 3D information.

Entities:  

Mesh:

Year:  2012        PMID: 22894441      PMCID: PMC4108707          DOI: 10.1118/1.4737109

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  A statistical 3-D pattern processing method for computer-aided detection of polyps in CT colonography.

Authors:  S B Göktürk; C Tomasi; B Acar; C F Beaulieu; D S Paik; R B Jeffrey; J Yee; S Napel
Journal:  IEEE Trans Med Imaging       Date:  2001-12       Impact factor: 10.048

2.  Model-based detection of lung nodules in computed tomography exams. Thoracic computer-aided diagnosis.

Authors:  Colin C McCulloch; Robert A Kaucic; Paulo R S Mendonça; Deborah J Walter; Ricardo S Avila
Journal:  Acad Radiol       Date:  2004-03       Impact factor: 3.173

3.  A novel computer-aided lung nodule detection system for CT images.

Authors:  Maxine Tan; Rudi Deklerck; Bart Jansen; Michel Bister; Jan Cornelis
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  A new computationally efficient CAD system for pulmonary nodule detection in CT imagery.

Authors:  Temesguen Messay; Russell C Hardie; Steven K Rogers
Journal:  Med Image Anal       Date:  2010-02-19       Impact factor: 8.545

5.  Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans.

Authors:  Qiang Li; Shusuke Sone; Kunio Doi
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

6.  Some practical issues of experimental design and data analysis in radiological ROC studies.

Authors:  C E Metz
Journal:  Invest Radiol       Date:  1989-03       Impact factor: 6.016

7.  Pulmonary nodules: automated detection on CT images with morphologic matching algorithm--preliminary results.

Authors:  Kyongtae T Bae; Jin-Sung Kim; Yong-Hum Na; Kwang Gi Kim; Jin-Hwan Kim
Journal:  Radiology       Date:  2005-06-13       Impact factor: 11.105

8.  Cancer statistics, 2010.

Authors:  Ahmedin Jemal; Rebecca Siegel; Jiaquan Xu; Elizabeth Ward
Journal:  CA Cancer J Clin       Date:  2010-07-07       Impact factor: 508.702

9.  Surface normal overlap: a computer-aided detection algorithm with application to colonic polyps and lung nodules in helical CT.

Authors:  David S Paik; Christopher F Beaulieu; Geoffrey D Rubin; Burak Acar; R Brooke Jeffrey; Judy Yee; Joyoni Dey; Sandy Napel
Journal:  IEEE Trans Med Imaging       Date:  2004-06       Impact factor: 10.048

10.  Automatic detection of small lung nodules on CT utilizing a local density maximum algorithm.

Authors:  Binsheng Zhao; Gordon Gamsu; Michelle S Ginsberg; Li Jiang; Lawrence H Schwartz
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

View more
  5 in total

1.  Large scale validation of the M5L lung CAD on heterogeneous CT datasets.

Authors:  E Lopez Torres; E Fiorina; F Pennazio; C Peroni; M Saletta; N Camarlinghi; M E Fantacci; P Cerello
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

2.  Effect of segmentation algorithms on the performance of computerized detection of lung nodules in CT.

Authors:  Wei Guo; Qiang Li
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

3.  CT temporal subtraction: techniques and clinical applications.

Authors:  Takatoshi Aoki; Tohru Kamiya; Huimin Lu; Takashi Terasawa; Midori Ueno; Yoshiko Hayashida; Seiichi Murakami; Yukunori Korogi
Journal:  Quant Imaging Med Surg       Date:  2021-06

4.  3D Convolutional Neural Network for Automatic Detection of Lung Nodules in Chest CT.

Authors:  Sardar Hamidian; Berkman Sahiner; Nicholas Petrick; Aria Pezeshk
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-03

5.  An Assisted Diagnosis System for Detection of Early Pulmonary Nodule in Computed Tomography Images.

Authors:  Ji-Kui Liu; Hong-Yang Jiang; Meng-di Gao; Chen-Guang He; Yu Wang; Pu Wang; He Ma; Ye Li
Journal:  J Med Syst       Date:  2016-12-28       Impact factor: 4.460

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.