Literature DB >> 16182043

Results of four-corner arthrodesis using dorsal circular plate fixation.

Corey B Kendall1, Timothy R Brown, S John Millon, L Edwin Rudisill, John L Sanders, Stephanie L Tanner.   

Abstract

PURPOSE: Four-corner arthrodesis with scaphoid excision has been used to reduce pain and preserve functional range of motion for patients with radioscaphoid arthritis. Early results of 4-corner arthrodesis with scaphoid excision using dorsal circular plate fixation are compared with reported results in the literature.
METHODS: We reviewed retrospectively the first 18 four-corner arthrodeses performed with this system by 4 hand surgeons. Two patients had revision surgery for nonunions before the study that were considered failures. Eight patients returned for final radiographs, objective examination, and functional questionnaire. The average follow-up period was 20 months (range, 13-33 mo). These results were compared with reported results in the literature using alternate fixation methods.
RESULTS: Radiographic union was achieved in only 3 wrists. Range of motion was 46% that of the opposite normal wrist and grip strength compared with the opposite wrist was 56%. Five patients would have the procedure again and 6 of 8 have returned to their original employment.
CONCLUSIONS: Four-corner arthrodesis with scaphoid excision using a circular internal fixation plate produced a high number of nonunions. Grip strength and range of motion results also were inferior to those reported in the literature.

Entities:  

Mesh:

Year:  2005        PMID: 16182043     DOI: 10.1016/j.jhsa.2005.04.007

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  22 in total

1.  High fusion rates with circular plate fixation for four-corner arthrodesis of the wrist.

Authors:  Ben Bedford; S Steven Yang
Journal:  Clin Orthop Relat Res       Date:  2010-01       Impact factor: 4.176

2.  The long-term outcome of four-corner fusion.

Authors:  Ian A Trail; Raj Murali; John Knowles Stanley; Michael John Hayton; Sumedh Talwalkar; Ramankutty Sreekumar; Ann Birch
Journal:  J Wrist Surg       Date:  2015-05

3.  Midterm Results of Four-Corner Fusion Using Dorsal Circular Plate Fixation.

Authors:  Ahmed Elgammal; Claus J Deglmann; Vanja Celigoj; Bernhard Lukas
Journal:  J Wrist Surg       Date:  2017-10-16

4.  Scapholunate advanced collapse (SLAC) and scaphoid nonunion advanced collapse (SNAC) wrist arthritis.

Authors:  Chirag M Shah; Peter J Stern
Journal:  Curr Rev Musculoskelet Med       Date:  2013-03

5.  Four corner fusion using a multidirectional angular stable locking plate.

Authors:  Tahseen Chaudhry; Michelle Spiteri; Dominic Power; Mark Brewster
Journal:  World J Orthop       Date:  2016-08-18

6.  Effectiveness of four-corner arthrodesis with use of a locked dorsal circular plate.

Authors:  Matthias Luegmair; Patrick Houvet
Journal:  Clin Orthop Relat Res       Date:  2012-03-20       Impact factor: 4.176

7.  The Learning Curve and Pitfalls of Arthroscopic Four-Corner Arthrodesis.

Authors:  Aleksi Vihanto; Tero Kotkansalo; Markus Pääkkönen
Journal:  J Wrist Surg       Date:  2019-02-20

8.  Four-corner fusion of the wrist: clinical and radiographic outcome of 31 patients.

Authors:  Andreas F Mavrogenis; Dimitrios A Flevas; Konstantinos Raptis; Panayiotis D Megaloikonomos; Vasilios G Igoumenou; Thekla Antoniadou; Leonidas Dimopoulos; Dimitrios Antonopoulos; Sarantis G Spyridonos
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-07-25

9.  Management of non-united four-corner fusions.

Authors:  Martin C Skie; Nicholas Gove; Despina E Ciocanel; Holly Smith
Journal:  Hand (N Y)       Date:  2007-03

10.  Scaphoid excision and limited wrist fusion: a comparison of K-wire and circular plate fixation.

Authors:  Jeffrey A Rodgers; Gary Holt; Edward P Finnerty; Blake Miller
Journal:  Hand (N Y)       Date:  2008-04-11