Literature DB >> 18780110

Scaphoid excision and limited wrist fusion: a comparison of K-wire and circular plate fixation.

Jeffrey A Rodgers1, Gary Holt, Edward P Finnerty, Blake Miller.   

Abstract

The purpose of this study was to compare the clinical outcome, union rate, and complications of a consecutive series of Scaphoid excision and limited wrist arthrodesis performed by a single surgeon using distal radius bone graft and K-wires or circular plate fixation. A sequential series of ten patients(11 wrists) who were stabilized with temporary K-wires were compared to 11 patients (11 wrists) who were stabilized with a circular plate. Minimum follow-up was 1 year. One patient in the K-wire group was converted to a wrist fusion. Six of the remaining ten patients in the K-wire fixation group and 8 of the 11 patients in the circular plate fixation group returned for the following blinded evaluations: Quick DASH, analog pain scale, range of motion, grip and pinch strength, plain x-ray, and multi-detector computed tomography evaluation. One non-union occurred in the K-wire group. There were no non-unions in the circular plate fixation group. There was no difference in any of remaining measures or rate of complications. This study shows that equivalent results can be obtained using circular plate fixation compared to K-wires when equivalent bone graft source and fusion technique are used. If K-wire removal requires a return to the OR, circular plate fixation is more cost-effective.

Entities:  

Year:  2008        PMID: 18780110      PMCID: PMC2525875          DOI: 10.1007/s11552-008-9099-x

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  9 in total

1.  Midcarpal arthrodesis with complete scaphoid excision and interposition bone graft in the treatment of advanced carpal collapse (SNAC/SLAC wrist): operative technique and outcome assessment.

Authors:  M Sauerbier; M Tränkle; G Linsner; B Bickert; G Germann
Journal:  J Hand Surg Br       Date:  2000-08

2.  Results of four-corner arthrodesis using dorsal circular plate fixation.

Authors:  Corey B Kendall; Timothy R Brown; S John Millon; L Edwin Rudisill; John L Sanders; Stephanie L Tanner
Journal:  J Hand Surg Am       Date:  2005-09       Impact factor: 2.230

3.  Long-term results of midcarpal arthrodesis in the treatment of scaphoid nonunion advanced collapse (SNAC-Wrist) and scapholunate advanced collapse (SLAC-Wrist).

Authors:  Andreas Dacho; Johanna Grundel; Gisbert Holle; Günter Germann; Michael Sauerbier
Journal:  Ann Plast Surg       Date:  2006-02       Impact factor: 1.539

4.  A prospective outcomes study of four-corner wrist arthrodesis using a circular limited wrist fusion plate for stage II scapholunate advanced collapse wrist deformity.

Authors:  Kevin C Chung; Andrew J Watt; Sandra V Kotsis
Journal:  Plast Reconstr Surg       Date:  2006-08       Impact factor: 4.730

5.  Complications and outcome of four-corner arthrodesis: circular plate fixation versus traditional techniques.

Authors:  Michael C Vance; Jon D Hernandez; Michael L Didonna; Peter J Stern
Journal:  J Hand Surg Am       Date:  2005-11       Impact factor: 2.230

6.  A modified technique of four-bone fusion for advanced carpal collapse (SLAC/SNAC wrist).

Authors:  A Garcia-López; M J Perez-Ubeda; F Marco; M Molina; L López-Duran
Journal:  J Hand Surg Br       Date:  2001-08

7.  MDCT versus digital radiography in the evaluation of bone healing in orthopedic patients.

Authors:  Christian R Krestan; Helge Noske; Violeta Vasilevska; Michael Weber; Gerd Schueller; Herwig Imhof; Christian Czerny
Journal:  AJR Am J Roentgenol       Date:  2006-06       Impact factor: 3.959

8.  Bone structure and turnover in the distal radius and iliac crest: a histomorphometric study.

Authors:  C M Schnitzler; S L Biddulph; J M Mesquita; K A Gear
Journal:  J Bone Miner Res       Date:  1996-11       Impact factor: 6.741

9.  Intercarpal arthrodesis by dowel bone grafting.

Authors:  M J Sandow; Y L Wai; M G Hayes
Journal:  J Hand Surg Br       Date:  1992-08
  9 in total
  4 in total

1.  Reliability of the 8 Week Time Point for Single Assessment of Midcarpal Fusion by CT Scan.

Authors:  Mark Henry
Journal:  J Hand Microsurg       Date:  2011-02-16

2.  Internal headless compression screw method for 4-corner fusion.

Authors:  Mark Henry
Journal:  J Hand Microsurg       Date:  2009-07-10

3.  Intercarpal fusions: indications, treatment options and techniques.

Authors:  Patrick Houvet
Journal:  EFORT Open Rev       Date:  2017-03-13

4.  3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate.

Authors:  Rebecca Woehl; Johannes Maier; Sebastian Gehmert; Christoph Palm; Birgit Riebschlaeger; Michael Nerlich; Michaela Huber
Journal:  BMC Musculoskelet Disord       Date:  2018-02-13       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.