Literature DB >> 16177527

Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study.

Warren D D'Souza1, Shahid A Naqvi, Cedric X Yu.   

Abstract

Significant differences between planned and delivered treatments may occur due to respiration-induced tumour motion, leading to underdosing of parts of the tumour and overdosing of parts of the surrounding critical structures. Existing methods proposed to counter tumour motion include breath-holds, gating and MLC-based tracking. Breath-holds and gating techniques increase treatment time considerably, whereas MLC-based tracking is limited to two dimensions. We present an alternative solution in which a robotic couch moves in real time in response to organ motion. To demonstrate proof-of-principle, we constructed a miniature adaptive couch model consisting of two movable platforms that simulate tumour motion and couch motion, respectively. These platforms were connected via an electronic feedback loop so that the bottom platform responded to the motion of the top platform. We tested our model with a seven-field step-and-shoot delivery case in which we performed three film-based experiments: (1) static geometry, (2) phantom-only motion and (3) phantom motion with simulated couch motion. Our measurements demonstrate that the miniature couch was able to compensate for phantom motion to the extent that the dose distributions were practically indistinguishable from those in static geometry. Motivated by this initial success, we investigated a real-time couch compensation system consisting of a stereoscopic infra-red camera system interfaced to a robotic couch known as the Hexapod, which responds in real time to any change in position detected by the cameras. Optical reflectors placed on a solid water phantom were used as surrogates for motion. We tested the effectiveness of couch-based motion compensation for fixed fields and a dynamic arc delivery cases. Due to hardware limitations, we performed film-based experiments (1), (2) and (3), with the robotic couch at a phantom motion period and dose rate of 16 s and 100 MU min(-1), respectively. Analysis of film measurements showed near-equivalent dose distributions (<or=2 mm agreement of corresponding isodose lines) for static geometry and motion-synchronized real-time robotic couch tracking-based radiation delivery.

Entities:  

Mesh:

Year:  2005        PMID: 16177527     DOI: 10.1088/0031-9155/50/17/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  54 in total

1.  Image-based dynamic multileaf collimator tracking of moving targets during intensity-modulated arc therapy.

Authors:  Per Rugaard Poulsen; Walther Fledelius; Byungchul Cho; Paul Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-03-06       Impact factor: 7.038

2.  [Image-guided radiation therapy].

Authors:  J Boda-Heggemann; M Guckenberger; U Ganswindt; C Belka; H Wertz; M Blessing; F Wenz; M Fuss; F Lohr
Journal:  Radiologe       Date:  2012-03       Impact factor: 0.635

3.  Verification of MLC based real-time tumor tracking using an electronic portal imaging device.

Authors:  Sarah Han-Oh; Byong Yong Yi; Fritz Lerma; Barry L Berman; Minzhi Gui; Cedric Yu
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

4.  Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method.

Authors:  Minzhi Gui; Yuanming Feng; Byongyong Yi; Anil Arvind Dhople; Cedric Yu
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

5.  Detailed analysis of latencies in image-based dynamic MLC tracking.

Authors:  Per Rugaard Poulsen; Byungchul Cho; Amit Sawant; Dan Ruan; Paul J Keall
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

6.  Optimization of an adaptive neural network to predict breathing.

Authors:  Martin J Murphy; Damodar Pokhrel
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

7.  Experimental investigation of a moving averaging algorithm for motion perpendicular to the leaf travel direction in dynamic MLC target tracking.

Authors:  Jai-Woong Yoon; Amit Sawant; Yelin Suh; Byung-Chul Cho; Tae-Suk Suh; Paul Keall
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

8.  Lung tumor tracking in fluoroscopic video based on optical flow.

Authors:  Qianyi Xu; Russell J Hamilton; Robert A Schowengerdt; Brian Alexander; Steve B Jiang
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Authors:  Amit Sawant; Raghu Venkat; Vikram Srivastava; David Carlson; Sergey Povzner; Herb Cattell; Paul Keall
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

10.  Tumor trailing strategy for intensity-modulated radiation therapy of moving targets.

Authors:  Alexei Trofimov; Christian Vrancic; Timothy C Y Chan; Gregory C Sharp; Thomas Bortfeld
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.