Literature DB >> 16177515

Characterization of a 2D ion chamber array for the verification of radiotherapy treatments.

E Spezi1, A L Angelini, F Romani, A Ferri.   

Abstract

In this study we investigated the characteristics of a commercial ion chamber array and its performance in the verification of radiotherapy plans. The device was the 2D Array Seven29 model (PTW, Freiburg, Germany). This is a two-dimensional detector array with 729 ionization chambers uniformly arranged in a 27 x 27 matrix with an active area of 27 x 27 cm(2). The detector short-, medium- and long-term reproducibility have been tested through an extensive set of repeated measurements. Short-term reproducibility was well within 0.2%. Medium- and long-term reproducibility were within 1%, including set-up reproducibility errors and linac output fluctuations. Dose linearity was also assessed. The system response to dose was verified to be linear within the range 2-500 MU. Output factors matched very well pinpoint chamber measurements performed in the same experimental conditions with a maximum local percentage difference of 0.4%. Furthermore, the 2D Array sensitivity to millimetric collimator positional changes and to perturbation effect of irradiated area was tested. The comparison with ion chamber data carried out in water was very satisfying. Finally, measurements of wedge-modulated fields and IMRT beam sequence matched very well ion chamber dose profiles acquired in a water tank. The extensive tests performed in this investigation show that the 2D Array Seven29 is a reliable and accurate dosimeter and that it could be a useful tool for the quality assurance and the verification of radiotherapy plans.

Entities:  

Mesh:

Year:  2005        PMID: 16177515     DOI: 10.1088/0031-9155/50/14/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  35 in total

1.  Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry.

Authors:  A J Vinall; A J Williams; V E Currie; A Van Esch; D Huyskens
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

2.  Dose verification for respiratory-gated volumetric modulated arc therapy.

Authors:  Jianguo Qian; Lei Xing; Wu Liu; Gary Luxton
Journal:  Phys Med Biol       Date:  2011-07-13       Impact factor: 3.609

3.  Improvement of I'mRT MatriXX in terms of spatial resolution and large area acquisition for patient-specific intensity-modulated radiotherapy verification.

Authors:  Arun S Oinam; Lakhwant Singh; S C Sharma; Pradeep Goswami
Journal:  J Med Phys       Date:  2009-07

4.  Advantage of 3D volumetric dosemeter in delivery quality assurance of dynamic arc therapy: comparison of pencil beam and Monte Carlo calculations.

Authors:  H-J Shin; J H Song; J-Y Jung; Y-K Kwak; C S Kay; Y-N Kang; B O Choi; H S Jang; S H Son
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

5.  Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system.

Authors:  C Guardiola; A Márquez; M C Jiménez-Ramos; J García López; A Baratto-Roldán; X Muñoz-Berbel
Journal:  Sci Rep       Date:  2021-05-17       Impact factor: 4.379

6.  A probability approach to the study on uncertainty effects on gamma index evaluations in radiation therapy.

Authors:  Francisco Cutanda Henríquez; Silvia Vargas Castrillón
Journal:  Comput Math Methods Med       Date:  2011-02-07       Impact factor: 2.238

7.  Implementation and validation of a commercial portal dosimetry software for intensity-modulated radiation therapy pre-treatment verification.

Authors:  C Varatharaj; Eugenia Moretti; M Ravikumar; Maria Rosa Malisan; Sanjay S Supe; Renato Padovani
Journal:  J Med Phys       Date:  2010-10

8.  Two years experience with quality assurance protocol for patient related Rapid Arc treatment plan verification using a two dimensional ionization chamber array.

Authors:  Daniela Wagner; Hilke Vorwerk
Journal:  Radiat Oncol       Date:  2011-02-22       Impact factor: 3.481

9.  Evaluation of PTW Seven29 for tomotherapy patient-specific quality assurance and comparison with ScandiDos Delta(4).

Authors:  Pamela Myers; Sotirios Stathakis; Alonso N Gutiérrez; Carlos Esquivel; Panayiotis Mavroidis; Niko Papanikolaou
Journal:  J Med Phys       Date:  2012-04

10.  Absolute dose verification of static intensity modulated radiation therapy (IMRT) with ion chambers of various volumes and TLD detectors.

Authors:  Hediye Acun-Bucht; Ebru Tuncay; Emin Darendeliler; Gönül Kemikler
Journal:  Rep Pract Oncol Radiother       Date:  2018-05-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.