Literature DB >> 16177510

Effect of errors in the system matrix on maximum a posteriori image reconstruction.

Jinyi Qi1, Ronald H Huesman.   

Abstract

Statistically based iterative image reconstruction methods have been developed for emission tomography. One important component in iterative image reconstruction is the system matrix, which defines the mapping from the image space to the data space. Several groups have demonstrated that an accurate system matrix can improve image quality in both single photon emission computed tomography (SPECT) and positron emission tomography (PET). While iterative methods are amenable to arbitrary and complicated system models, the true system response is never known exactly. In practice, one also has to sacrifice the accuracy of the system model because of limited computing and imaging resources. This paper analyses the effect of errors in the system matrix on iterative image reconstruction methods that are based on the maximum a posteriori principle. We derived an analytical expression for calculating artefacts in a reconstructed image that are caused by errors in the system matrix using the first-order Taylor series approximation. The theoretical expression is used to determine the required minimum accuracy of the system matrix in emission tomography. Computer simulations show that the theoretical results work reasonably well in low-noise situations.

Mesh:

Year:  2005        PMID: 16177510      PMCID: PMC1382175          DOI: 10.1088/0031-9155/50/14/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  36 in total

1.  A slice-by-slice blurring model and kernel evaluation using the Klein-Nishina formula for 3D scatter compensation in parallel and converging beam SPECT.

Authors:  C Bai; G L Zeng; G T Gullberg
Journal:  Phys Med Biol       Date:  2000-05       Impact factor: 3.609

2.  Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.

Authors:  Freek J Beekman; Hugo W A M de Jong; Sander van Geloven
Journal:  IEEE Trans Med Imaging       Date:  2002-08       Impact factor: 10.048

3.  A 3D model of non-uniform attenuation and detector response for efficient iterative reconstruction in SPECT.

Authors:  D R Gilland; R J Jaszczak; H Wang; T G Turkington; K L Greer; R E Coleman
Journal:  Phys Med Biol       Date:  1994-03       Impact factor: 3.609

4.  Regularized constrained total least squares image restoration.

Authors:  V Z Mesarovic; N P Galatsanos; A K Katsaggelos
Journal:  IEEE Trans Image Process       Date:  1995       Impact factor: 10.856

5.  Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images.

Authors:  E U Mumcuoglu; R Leahy; S R Cherry; Z Zhou
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  Regularized total least squares approach for nonconvolutional linear inverse problems.

Authors:  W Zhu; Y Wang; N P Galatsanos; J Zhang
Journal:  IEEE Trans Image Process       Date:  1999       Impact factor: 10.856

7.  Transmission-based scatter correction of 180 degrees myocardial single-photon emission tomographic studies.

Authors:  B F Hutton; A Osiecki; S R Meikle
Journal:  Eur J Nucl Med       Date:  1996-10

8.  Iterative total least-squares image reconstruction algorithm for optical tomography by the conjugate gradient method.

Authors:  W Zhu; Y Wang; Y Yao; J Chang; H L Graber; R L Barbour
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1997-04       Impact factor: 2.129

9.  A transmission-dependent method for scatter correction in SPECT.

Authors:  S R Meikle; B F Hutton; D L Bailey
Journal:  J Nucl Med       Date:  1994-02       Impact factor: 10.057

10.  Improved SPECT quantification using compensation for scattered photons.

Authors:  R J Jaszczak; K L Greer; C E Floyd; C C Harris; R E Coleman
Journal:  J Nucl Med       Date:  1984-08       Impact factor: 10.057

View more
  8 in total

1.  Analysis of penalized likelihood image reconstruction for dynamic PET quantification.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2009-02-10       Impact factor: 10.048

2.  A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

Authors:  Xing Rong; Yong Du; Eric C Frey
Journal:  Phys Med Biol       Date:  2012-05-23       Impact factor: 3.609

3.  A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

Authors:  Lin Fu; Jinyi Qi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

4.  Ultra-low dose CT attenuation correction for PET/CT.

Authors:  Ting Xia; Adam M Alessio; Bruno De Man; Ravindra Manjeshwar; Evren Asma; Paul E Kinahan
Journal:  Phys Med Biol       Date:  2011-12-09       Impact factor: 3.609

5.  A Constrained Variable Projection Reconstruction Method for Photoacoustic Computed Tomography Without Accurate Knowledge of Transducer Responses.

Authors:  Qiwei Sheng; Kun Wang; Thomas P Matthews; Jun Xia; Liren Zhu; Lihong V Wang; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2015-12       Impact factor: 10.048

6.  Robust framework for PET image reconstruction incorporating system and measurement uncertainties.

Authors:  Huafeng Liu; Song Wang; Fei Gao; Yi Tian; Wufan Chen; Zhenghui Hu; Pengcheng Shi
Journal:  PLoS One       Date:  2012-03-12       Impact factor: 3.240

7.  High fidelity system modeling for high quality image reconstruction in clinical CT.

Authors:  Synho Do; William Clem Karl; Sarabjeet Singh; Mannudeep Kalra; Tom Brady; Ellie Shin; Homer Pien
Journal:  PLoS One       Date:  2014-11-12       Impact factor: 3.240

8.  Measured PET Data Characterization with the Negative Binomial Distribution Model.

Authors:  Maria Filomena Santarelli; Vincenzo Positano; Luigi Landini
Journal:  J Med Biol Eng       Date:  2017-03-24       Impact factor: 1.553

  8 in total