Literature DB >> 26641726

A Constrained Variable Projection Reconstruction Method for Photoacoustic Computed Tomography Without Accurate Knowledge of Transducer Responses.

Qiwei Sheng, Kun Wang, Thomas P Matthews, Jun Xia, Liren Zhu, Lihong V Wang, Mark A Anastasio.   

Abstract

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging system employs conventional piezoelectric ultrasonic transducers, the ideal photoacoustic (PA) signals are degraded by the transducers' acousto-electric impulse responses (EIRs) during the measurement process. If unaccounted for, this can degrade the accuracy of the reconstructed image. In principle, the effect of the EIRs on the measured PA signals can be ameliorated via deconvolution; images can be reconstructed subsequently by application of a reconstruction method that assumes an idealized EIR. Alternatively, the effect of the EIR can be incorporated into an imaging model and implicitly compensated for during reconstruction. In either case, the efficacy of the correction can be limited by errors in the assumed EIRs. In this work, a joint optimization approach to PACT image reconstruction is proposed for mitigating errors in reconstructed images that are caused by use of an inaccurate EIR. The method exploits the bi-linear nature of the imaging model and seeks to refine the measured EIR during the process of reconstructing the sought-after absorbed optical energy density. Computer-simulation and experimental studies are conducted to investigate the numerical properties of the method and demonstrate its value for mitigating image distortions and enhancing the visibility of fine structures.

Entities:  

Mesh:

Year:  2015        PMID: 26641726      PMCID: PMC5886799          DOI: 10.1109/TMI.2015.2437356

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  20 in total

1.  Thermoacoustic computed tomography--technical considerations.

Authors:  R A Kruger; D R Reinecke; G A Kruger
Journal:  Med Phys       Date:  1999-09       Impact factor: 4.071

2.  Whole-body ring-shaped confocal photoacoustic computed tomography of small animals in vivo.

Authors:  Jun Xia; Muhammad R Chatni; Konstantin Maslov; Zijian Guo; Kun Wang; Mark Anastasio; Lihong V Wang
Journal:  J Biomed Opt       Date:  2012-05       Impact factor: 3.170

3.  Fast gradient-based algorithms for constrained total variation image denoising and deblurring problems.

Authors:  Amir Beck; Marc Teboulle
Journal:  IEEE Trans Image Process       Date:  2009-07-24       Impact factor: 10.856

4.  Curved array photoacoustic tomographic system for small animal imaging.

Authors:  John Gamelin; Andres Aguirre; Anastasios Maurudis; Fei Huang; Diego Castillo; Lihong V Wang; Quing Zhu
Journal:  J Biomed Opt       Date:  2008 Mar-Apr       Impact factor: 3.170

5.  Model-based optoacoustic inversion with arbitrary-shape detectors.

Authors:  Amir Rosenthal; Vasilis Ntziachristos; Daniel Razansky
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

6.  An imaging model incorporating ultrasonic transducer properties for three-dimensional optoacoustic tomography.

Authors:  Kun Wang; Sergey A Ermilov; Richard Su; Hans-Peter Brecht; Alexander A Oraevsky; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2010-09-02       Impact factor: 10.048

7.  Discrete imaging models for three-dimensional optoacoustic tomography using radially symmetric expansion functions.

Authors:  Kun Wang; Robert W Schoonover; Richard Su; Alexander Oraevsky; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2014-05       Impact factor: 10.048

8.  Enhancement of photoacoustic tomography by ultrasonic computed tomography based on optical excitation of elements of a full-ring transducer array.

Authors:  Jun Xia; Chao Huang; Konstantin Maslov; Mark A Anastasio; Lihong V Wang
Journal:  Opt Lett       Date:  2013-08-15       Impact factor: 3.776

9.  Investigation of iterative image reconstruction in three-dimensional optoacoustic tomography.

Authors:  Kun Wang; Richard Su; Alexander A Oraevsky; Mark A Anastasio
Journal:  Phys Med Biol       Date:  2012-08-03       Impact factor: 3.609

10.  Investigation of the far-field approximation for modeling a transducer's spatial impulse response in photoacoustic computed tomography.

Authors:  Kenji Mitsuhashi; Kun Wang; Mark A Anastasio
Journal:  Photoacoustics       Date:  2014-03-01
View more
  2 in total

1.  Image reconstruction for endoscopic photoacoustic tomography including effects of detector responses.

Authors:  Zheng Sun; Huifeng Sun
Journal:  Exp Biol Med (Maywood)       Date:  2022-03-01

2.  Image improvement in linear-array photoacoustic imaging using high resolution coherence factor weighting technique.

Authors:  Moein Mozaffarzadeh; Bahador Makkiabadi; Maryam Basij; Mohammad Mehrmohammadi
Journal:  BMC Biomed Eng       Date:  2019-04-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.