Literature DB >> 16177400

Radiation dose to patients and radiologists during transcatheter arterial embolization: comparison of a digital flat-panel system and conventional unit.

Shigeru Suzuki1, Shigeru Furui, Ikuo Kobayashi, Teiyu Yamauchi, Hiroshi Kohtake, Koji Takeshita, Koichi Takada, Masafumi Yamagishi.   

Abstract

OBJECTIVE: The objective of our study was to evaluate the exposure doses to patients and radiologists during transcatheter arterial embolization (TAE) for hepatocellular carcinoma (HCC) using a new angiographic unit with a digital flat-panel system. SUBJECTS AND METHODS: Doses were assessed for 24 procedures: 12 using a new unit with a digital flat-panel system and 12 using a conventional unit. Doses to patients' skin were evaluated with thermoluminescent dosimeters behind the left, middle, and right portions of the liver. The doses to the radiologists were measured by an electronic personal dosimeter placed on the chest outside a lead protector. The maximal skin doses to the patients and the dose equivalents, Hp(0.07), to the radiologists were compared between the two procedure groups with each angiographic unit.
RESULTS: For procedures with the new unit, the mean maximal skin dose to the patients was 284 +/- 127 (SD) mGy (range, 130-467 mGy), and Hp(0.07) to the radiologists was 62.8 +/- 17.4 muSv. For procedures with the conventional unit, the maximal skin dose to the patients was 1,068 +/- 439 mGy (range, 510-1,882 mGy), and Hp(0.07) to the radiologists was 68.4 +/- 25.7 muSv. The maximal skin dose to the patients was significantly lower with the new unit than with the conventional unit (p < 0.0005). There was no significant difference in the Hp(0.07) to the radiologists between the two procedure groups.
CONCLUSION: The new digital flat-panel system for angiographic imaging can reduce the radiation dose to patients' skin during TAE for HCC as compared with the conventional system.

Entities:  

Mesh:

Year:  2005        PMID: 16177400     DOI: 10.2214/AJR.04.1580

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Radiation exposure of operator performing interventional procedures using a flat panel angiography system: evaluation with photoluminescence glass dosimeters.

Authors:  Yoshinori Funama; Nozomu Nagasue; Kazuo Awai; Ichiro Sakamoto; Kiyotaka Kakei; Masamichi Shimamura; Yasuyuki Yamashita; Masataka Uetani
Journal:  Jpn J Radiol       Date:  2010-07-27       Impact factor: 2.374

2.  Comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system in image-guided central venous catheter placement in children weighing less than 10 kg.

Authors:  Roberto Miraglia; Luigi Maruzzelli; Kelvin Cortis; Marcello Piazza; Roberta Gerasia; Simona Maggio; Fabio Tuzzolino; Angelo Luca
Journal:  Pediatr Radiol       Date:  2014-09-10

3.  Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT.

Authors:  M Doelken; T Struffert; G Richter; T Engelhorn; C Nimsky; O Ganslandt; T Hammen; A Doerfler
Journal:  Neuroradiology       Date:  2008-03-11       Impact factor: 2.804

4.  A survey of radiation dose to patients and operators during radiofrequency ablation using computed tomography.

Authors:  A Saidatul; Ca Azlan; Msa Megat Amin; Bjj Abdullah; Kh Ng
Journal:  Biomed Imaging Interv J       Date:  2010-01-01

5.  Comparing ovarian radiation doses in flat-panel and conventional angiography during uterine artery embolization: a randomized clinical trial.

Authors:  Kavous Firouznia; Hossein Ghanaati; Aliakbar Sharafi; Firouze Abahashemi; Hassan Hashemi; Amir Hossein Jalali; Madjid Shakiba
Journal:  Iran J Radiol       Date:  2013-08-30       Impact factor: 0.212

6.  Percutaneous Glycerol Rhizotomy for Trigeminal Neuralgia Using a Single-Plane, Flat Panel Detector Angiography System: Technical Note.

Authors:  Hidetaka Arishima; Satoshi Kawajiri; Hiroshi Arai; Yoshifumi Higashino; Toshiaki Kodera; Ken-Ichiro Kikuta
Journal:  Neurol Med Chir (Tokyo)       Date:  2016-04-04       Impact factor: 1.742

  6 in total