Literature DB >> 16177013

Radiation exposure in stent-grafting of abdominal aortic aneurysms.

H Geijer1, T Larzon, R Popek, K-W Beckman.   

Abstract

In recent years, endovascular stent-grafting of abdominal aortic aneurysms has become more and more common. The radiation dose associated with these procedures is not well documented however. The aim of the present study was to estimate the radiation exposure and to simulate the effects of a switch from C-arm radiographic equipment to a dedicated angiographic suite. Dose-area product (DAP) was recorded for 24 aortic stent-grafting procedures. Based on these data, entrance surface dose (ESD) and effective dose were calculated. A simulation of doses at various settings was also performed using a humanoid Alderson phantom. The image quality was evaluated with a CDRAD contrast-detail phantom. The mean DAP was 72.3 Gy cm(2) at 28 min fluoroscopy time with a mean ESD of 0.39 Gy and a mean effective dose of 10.5 mSv. If the procedures had been performed in an angiographic suite, all dose values would be much higher with a mean ESD of 2.9 Gy with 16 patients exceeding 2 Gy, which is considered to be a threshold for possible skin injury. The image quality for fluoroscopy was superior for the C-arm whilst the angiographic unit gave better acquisition images. Using a C-arm unit resulted in doses similar to percutaneous coronary intervention (PCI). If the same patients had been treated using dedicated angiographic equipment, the risk of skin injury would be much higher. It is thus important to be aware of the dose output of the equipment that is used.

Entities:  

Mesh:

Year:  2005        PMID: 16177013     DOI: 10.1259/bjr/72629938

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  13 in total

1.  Risk of deterministic effects during endovascular aortic stent graft implantation.

Authors:  D Kuhelj; U Zdesar; V Jevtic; D Skrk; G Omahen; D Zontar; M Surlan; M Glusic; P Popovic; I J Kocijancic; V Salapura
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

2.  Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It.

Authors:  Rui Machado; Vitor Miguel Dias Ferreira; Luis Loureiro; João Gonçalves; Pedro Oliveira; Rui Almeida
Journal:  Braz J Cardiovasc Surg       Date:  2016 Nov-Dec

3.  Electromagnetic navigation versus fluoroscopy in aortic endovascular procedures: a phantom study.

Authors:  Kjetil Tystad Lund; Geir Arne Tangen; Frode Manstad-Hulaas
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-08-04       Impact factor: 2.924

4.  Typical exposure parameters, organ doses and effective doses for endovascular aortic aneurysm repair: Comparison of Monte Carlo simulations and direct measurements with an anthropomorphic phantom.

Authors:  Monika Foerth; Michael C Seidenbusch; Mojtaba Sadeghi-Azandaryani; Ursula Lechel; Karla Maria Treitl; Marcus Treitl
Journal:  Eur Radiol       Date:  2015-04-09       Impact factor: 5.315

5.  Impact of intracardiac echocardiography on radiation exposure during adult congenital heart disease catheter-based interventions.

Authors:  Gianluca Rigatelli; Paolo Cardaioli; Loris Roncon; Massimo Giordan; Emiliano Bedendo; Laura Oliva; Stefano Panin; Pietro Zonzin
Journal:  Int J Cardiovasc Imaging       Date:  2006-07-05       Impact factor: 2.357

6.  The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair.

Authors:  Rita Fossaceca; Marco Brambilla; Giuseppe Guzzardi; Paolo Cerini; Alessandra Renghi; Serena Valzano; Piero Brustia; Alessandro Carriero
Journal:  Eur Radiol       Date:  2012-05-23       Impact factor: 5.315

7.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

8.  Endovascular treatment of complex diseases of the thoracic aorta-10 years single centre experience.

Authors:  Piotr Buczkowski; Mateusz Puślecki; Natalia Majewska; Tomasz Urbanowicz; Marcin Misterski; Robert Juszkat; Jerzy Kulesza; Bartosz Żabicki; Sebastian Stefaniak; Marcin Ligowski; Lukasz Szarpak; Marek Jemielity; Eva Rivas; Kurt Ruetzler; Bartłomiej Perek
Journal:  J Thorac Dis       Date:  2019-06       Impact factor: 2.895

9.  Clinical factors increasing radiation doses to patients undergoing long-lasting procedures: abdominal stent-graft implantation.

Authors:  Natalia Majewska; Michal G Stanisic; Magdalena Aleksandra Blaszak; Robert Juszkat; Maciej Frankiewicz; Zbigniew Krasinski; Marcin Makalowski; Waclaw Majewski
Journal:  Med Sci Monit       Date:  2011-11

10.  The radiation burden from increasingly complex endovascular aortic aneurysm repair.

Authors:  Avnesh S Thakor; Andrew Winterbottom; Mathew Mercuri; Claire Cousins; Michael E Gaunt
Journal:  Insights Imaging       Date:  2011-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.