Literature DB >> 28076617

Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It.

Rui Machado1, Vitor Miguel Dias Ferreira1, Luis Loureiro1, João Gonçalves1, Pedro Oliveira2, Rui Almeida1.   

Abstract

Objective: The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it.
Methods: Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP)), fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics.
Results: This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m(2), and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors.
Conclusion: The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m(2)) with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.

Entities:  

Mesh:

Year:  2016        PMID: 28076617      PMCID: PMC5407135          DOI: 10.5935/1678-9741.20160084

Source DB:  PubMed          Journal:  Braz J Cardiovasc Surg        ISSN: 0102-7638


  24 in total

1.  Evaluation of radiation during EVAR performed on a mobile C-arm.

Authors:  B Maurel; J Sobocinski; P Perini; M Guillou; M Midulla; R Azzaoui; S Haulon
Journal:  Eur J Vasc Endovasc Surg       Date:  2011-11-02       Impact factor: 7.069

Review 2.  Debate: whether young, good-risk patients should be treated with endovascular abdominal aortic aneurysm repair.

Authors:  Raghuveer Vallabhaneni; Mark A Farber; Fabrice Schneider; Jean-Baptiste Ricco
Journal:  J Vasc Surg       Date:  2013-12       Impact factor: 4.268

3.  Guidelines for patient radiation dose management.

Authors:  Michael S Stecker; Stephen Balter; Richard B Towbin; Donald L Miller; Eliseo Vañó; Gabriel Bartal; J Fritz Angle; Christine P Chao; Alan M Cohen; Robert G Dixon; Kathleen Gross; George G Hartnell; Beth Schueler; John D Statler; Thierry de Baère; John F Cardella
Journal:  J Vasc Interv Radiol       Date:  2009-07       Impact factor: 3.464

4.  A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms.

Authors:  Monique Prinssen; Eric L G Verhoeven; Jaap Buth; Philippe W M Cuypers; Marc R H M van Sambeek; Ron Balm; Erik Buskens; Diederick E Grobbee; Jan D Blankensteijn
Journal:  N Engl J Med       Date:  2004-10-14       Impact factor: 91.245

5.  Direct and indirect measurement of patient radiation exposure during endovascular aortic aneurysm repair.

Authors:  Dustin J Weiss; Iraklis I Pipinos; G Mathew Longo; Thomas G Lynch; Frank J Rutar; Jason M Johanning
Journal:  Ann Vasc Surg       Date:  2008-11       Impact factor: 1.466

6.  Radiation burden of patients undergoing endovascular abdominal aortic aneurysm repair.

Authors:  John A Kalef-Ezra; Stratos Karavasilis; Dimosthenis Ziogas; Dimitris Dristiliaris; Lampros K Michalis; Miltiadis Matsagas
Journal:  J Vasc Surg       Date:  2009-02       Impact factor: 4.268

7.  Radiation exposure during endovascular aneurysm repair.

Authors:  R A Weerakkody; S R Walsh; C Cousins; K E Goldstone; T Y Tang; M E Gaunt
Journal:  Br J Surg       Date:  2008-06       Impact factor: 6.939

8.  Outcomes following endovascular vs open repair of abdominal aortic aneurysm: a randomized trial.

Authors:  Frank A Lederle; Julie A Freischlag; Tassos C Kyriakides; Frank T Padberg; Jon S Matsumura; Ted R Kohler; Peter H Lin; Jessie M Jean-Claude; Dolores F Cikrit; Kathleen M Swanson; Peter N Peduzzi
Journal:  JAMA       Date:  2009-10-14       Impact factor: 56.272

9.  Efficacy Analysis of a Script-based Guide for EVAR Execution: is it Possible to Reduce Patient Exposure to Contrast, Operative Time and Blood Loss even when Advanced Technologies are not Available?

Authors:  Giovani José Dal Poggetto Molinari; Ana Terezinha Guillaumon; Andréia Marques de Oliveira Dalbem
Journal:  Braz J Cardiovasc Surg       Date:  2015 Nov-Dec

10.  The European Directive on health protection of individuals against the dangers of ionising radiation in relation to medical exposures (97/43/EURATOM).

Authors:  D Teunen
Journal:  J Radiol Prot       Date:  1998-06       Impact factor: 1.394

View more
  1 in total

Review 1.  The Nellix endovascular aneurysm sealing system: current perspectives.

Authors:  Xin Y Choo; Shahab Hajibandeh; Shahin Hajibandeh; George A Antoniou
Journal:  Med Devices (Auckl)       Date:  2019-02-19
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.