Literature DB >> 16176179

Preliminary evaluation of the Iris IQ 200 automated urine analyser.

Lia Alves1, Frederic Ballester, Jordi Camps, Jorge Joven.   

Abstract

The IRIS IQ 200 automated urine analyser is a microscope associated to digital imaging software, and is able to classify urine particles into 12 categories and report quantitative results. We evaluated this analyser with respect to linearity and precision, and compared results with microscopic examination of the urine sediment, and with the measurement of urine strips in a CLINITEK 500 analyser. The assay was linear between 10 and 1030 particles/microL. The detection limit was 6 particles/microL. Intra- and inter-assay coefficients of variation were 1.9% and 2.3%. Results by the IQ 200 analyser showed highly significant correlations with those of the urine sediment (erythrocytes: rho=0.68; leukocytes: rho=0.60; epithelial cells: rho=0.66; p<0.001), and urine strips (erythrocytes: rho=0.67; leukocytes: rho=0.66; p<0.001). These results indicate that the IRIS IQ 200 analyser may play a useful part in the automated examination and measurement of urine specimens.

Mesh:

Year:  2005        PMID: 16176179     DOI: 10.1515/CCLM.2005.166

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  6 in total

1.  New generation IQ-200 automated urine microscopy analyzer compared with KOVA cell chamber.

Authors:  Emel Altekin; Ozgur Kadiçesme; Pinar Akan; Tuncay Kume; Ozgul Vupa; Gul Ergor; Hakan Abacioglu
Journal:  J Clin Lab Anal       Date:  2010       Impact factor: 2.352

2.  Clinical laboratory automated urinalysis: comparison among automated microscopy, flow cytometry, two test strips analyzers, and manual microscopic examination of the urine sediments.

Authors:  S Mayo; D Acevedo; C Quiñones-Torrelo; I Canós; M Sancho
Journal:  J Clin Lab Anal       Date:  2008       Impact factor: 2.352

3.  High False Positives and False Negatives in Yeast Parameter in an Automated Urine Sediment Analyzer.

Authors:  Ozgur Aydin; Hamit Yasar Ellidag; Esin Eren; Necat Yilmaz
Journal:  J Med Biochem       Date:  2015-07-14       Impact factor: 3.402

4.  Comparison of the performance of the IDEXX SediVue Dx® with manual microscopy for the detection of cells and 2 crystal types in canine and feline urine.

Authors:  Annalisa M Hernandez; Graham E A Bilbrough; Dennis B DeNicola; Celine Myrick; Suzanne Edwards; Jeremy M Hammond; Alex N Myers; Johanna C Heseltine; Karen Russell; Marco Giraldi; Mary B Nabity
Journal:  J Vet Intern Med       Date:  2018-12-03       Impact factor: 3.333

5.  A comparison of automated urine analyzers cobas 6500, UN 3000-111b and iRICELL 3000 with manual microscopic urinalysis.

Authors:  Piraya Tantisaranon; Kanyarat Dumkengkhachornwong; Peechana Aiadsakun; Areerat Hnoonual
Journal:  Pract Lab Med       Date:  2021-01-18

6.  The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis.

Authors:  Fatma Demet İnce; Hamit Yaşar Ellidağ; Mehmet Koseoğlu; Neşe Şimşek; Hülya Yalçın; Mustafa Osman Zengin
Journal:  Pract Lab Med       Date:  2016-03-11
  6 in total