Literature DB >> 16161743

A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants.

Stephen F Balshi1, Fred D Allen, Glenn J Wolfinger, Thomas J Balshi.   

Abstract

PURPOSE: This study evaluated the stability of implants in 51 patients following a clinical protocol of immediate functional loading. The stability during the first 3 months following implant placement was assessed according to bone type, implant location, and patient gender.
MATERIALS AND METHODS: Twenty-two male and 29 female patients were treated with 344 Brånemark System implants placed in edentulous bone or extraction sites and put into functional loading using the Teeth in a Day protocol. Each implant was tested for primary stability with resonance frequency analysis (RFA) at the time of implant placement, and RFA was performed at examinations 30, 60, and 90 days following surgery.
RESULTS: The analysis was based on the 276 implants that were successfully measured using RFA at all postoperative intervals. The clinical implant survival rate was 98.5% for the total population. RFA showed a decrease in bone-implant stability in the first month after implant placement from 70.35 +/- 0.5 to 66.38 +/- 0.50, followed by increases in stability in the second and third months (68.01 +/- 0.50 and 68.82 +/- 0.49, respectively), suggesting a process of adaptive bone remodeling around the implant. In general, lower initial stabilities were seen in softer bone types, in the posterior portions of the jaw compared to anterior areas, and in the female population. DISCUSSION AND
CONCLUSION: The results of this study suggest an immediate loading protocol should have an undisturbed period of healing for the first 2 months following implant placement. The determination of "predictor" stability levels for different clinical conditions were based on multiple splinted implants, allowing a larger surface area to withstand the distribution of the load. The most significant "predictor" values from a surgical and prosthodontic perspective are those determined in soft bone, in reduced bone, or in areas where lever arms are created as a result of long spans between the implants.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16161743

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  11 in total

1.  Peri-implant complications for posterior endosteal implants.

Authors:  Josephine Esquivel-Upshaw; Alex Mehler; Arthur Clark; Dan Neal; Luiz Gonzaga; Kenneth Anusavice
Journal:  Clin Oral Implants Res       Date:  2014-09-27       Impact factor: 5.977

2.  Vibrational analysis of mandible trauma: experimental and numerical approaches.

Authors:  Shu-Li Lin; Sheng-Yang Lee; Long-Yi Lee; Wen-Ta Chiu; Che-Tong Lin; Haw-Ming Huang
Journal:  Med Biol Eng Comput       Date:  2006-08-22       Impact factor: 2.602

3.  Stability changes of miniscrew implants over time.

Authors:  Derid S Ure; Donald R Oliver; Ki Beom Kim; Ana Cláudia Melo; Peter H Buschang
Journal:  Angle Orthod       Date:  2011-05-25       Impact factor: 2.079

4.  Stability and survival of bone-anchored hearing aid implant systems in post-irradiated patients.

Authors:  Mark D Wilkie; Kathryn A Lightbody; Ali A Salamat; Kalyan M Chakravarthy; David A Luff; Robert H Temple
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-02-17       Impact factor: 2.503

5.  Mini-implant stability at the initial healing period: a clinical pilot study.

Authors:  Manuel Nienkemper; Benedict Wilmes; Alexander Pauls; Dieter Drescher
Journal:  Angle Orthod       Date:  2013-07-24       Impact factor: 2.079

6.  A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis.

Authors:  In-Ho Kang; Chang-Whe Kim; Young-Jun Lim; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

7.  Influence of a Novel Surface of Bioactive Implants on Osseointegration: A Comparative and Histomorfometric Correlation and Implant Stability Study in Minipigs.

Authors:  Manuel M Romero-Ruiz; Francisco Javier Gil-Mur; José Vicente Ríos-Santos; Pedro Lázaro-Calvo; Blanca Ríos-Carrasco; Mariano Herrero-Climent
Journal:  Int J Mol Sci       Date:  2019-05-09       Impact factor: 5.923

8.  Combination Use of BMP2 and VEGF165 Promotes Osseointegration and Stability of Titanium Implants in Irradiated Bone.

Authors:  Bo Huang; Qianqian Yao; Yan Huang; Liang Zhang; Yang Yao; Ping Gong; Hua Tang
Journal:  Biomed Res Int       Date:  2018-11-29       Impact factor: 3.411

9.  Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading.

Authors:  Hasan Sarfaraz; Shefali Johri; P Sucheta; Sripathi Rao
Journal:  J Indian Prosthodont Soc       Date:  2018 Apr-Jun

10.  Fractal analysis as a useful predictor for determining osseointegration of dental implant? A retrospective study.

Authors:  Emrah Soylu; Aykağan Coşgunarslan; Selin Çelebi; Damla Soydan; Ahmet Emin Demirbaş; Osman Demir
Journal:  Int J Implant Dent       Date:  2021-02-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.