Literature DB >> 16148395

An improved MCNP version of the NORMAN voxel phantom for dosimetry studies.

P Ferrari1, G Gualdrini.   

Abstract

In recent years voxel phantoms have been developed on the basis of tomographic data of real individuals allowing new sets of conversion coefficients to be calculated for effective dose. Progress in radiation studies brought ICRP to revise its recommendations and a new report, already circulated in draft form, is expected to change the actual effective dose evaluation method. In the present paper the voxel phantom NORMAN developed at HPA, formerly NRPB, was employed with MCNP Monte Carlo code. A modified version of the phantom, NORMAN-05, was developed to take into account the new set of tissues and weighting factors proposed in the cited ICRP draft. Air kerma to organ equivalent dose and effective dose conversion coefficients for antero-posterior and postero-anterior parallel photon beam irradiations, from 20 keV to 10 MeV, have been calculated and compared with data obtained in other laboratories using different numerical phantoms. Obtained results are in good agreement with published data with some differences for the effective dose calculated employing the proposed new tissue weighting factors set in comparison with previous evaluations based on the ICRP 60 report.

Entities:  

Mesh:

Year:  2005        PMID: 16148395     DOI: 10.1088/0031-9155/50/18/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Hybrid computational phantoms representing the reference adult male and adult female: construction and applications for retrospective dosimetry.

Authors:  Jorge L Hurtado; Choonsik Lee; Daniel Lodwick; Timothy Goede; Jonathan L Williams; Wesley E Bolch
Journal:  Health Phys       Date:  2012-03       Impact factor: 1.316

2.  Evaluation of the use of surrogate tissues for calculating radiation dose to lymphatic nodes from external photon beams.

Authors:  Stephanie Lamart; Brian E Moroz; Choonsik Lee
Journal:  Radiat Prot Dosimetry       Date:  2013-07-11       Impact factor: 0.972

3.  Development of a paediatric head voxel model database for dosimetric applications.

Authors:  Andreas Stratis; Nathan Touyz; Guozhi Zhang; Reinhilde Jacobs; Ria Bogaerts; Hilde Bosmans
Journal:  Br J Radiol       Date:  2017-07-27       Impact factor: 3.039

Review 4.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

5.  Pre-therapeutic (124)I PET(/CT) dosimetry confirms low average absorbed doses per administered (131)I activity to the salivary glands in radioiodine therapy of differentiated thyroid cancer.

Authors:  Walter Jentzen; Robert F Hobbs; Alexander Stahl; Jochen Knust; George Sgouros; Andreas Bockisch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-01-13       Impact factor: 9.236

6.  A study of predicted bone marrow distribution on calculated marrow dose from external radiation exposures using two sets of image data for the same individual.

Authors:  Peter F Caracappa; T C Ephraim Chao; X George Xu
Journal:  Health Phys       Date:  2009-06       Impact factor: 1.316

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.