Literature DB >> 16143559

Mechanical properties of the human uterine cervix: an in vivo study.

Edoardo Mazza1, Alessandro Nava, Margit Bauer, Raimund Winter, Michael Bajka, Gerhard A Holzapfel.   

Abstract

Experimental results of in vivo measurements to characterize the mechanical behaviour of human uterine cervices are documented. Aspiration experiments were performed on eight uteri in vivo, before vaginal/abdominal hysterectomy, and four uteri were also tested ex vivo, approximately 1.5h after extraction. The reproducibility of the mechanical data from the in vivo aspiration experiments has been analysed. For an introduced "stiffness parameter" the organ specific SD is 22%, so that the proposed experimental procedure allows detections of 30% changes with respect to a reference value of the stiffness parameter. A comparison of in vivo and ex vivo data from the same organ has shown that: (i) the ex vivo mechanical response of the uterine cervix tissue does not differ considerably from that observed in vivo; (ii) some differences can be identified in tissue pre-conditioning with ex vivo showing a stronger history dependence with respect to in vivo; (iii) the differences in the time dependence of the mechanical response are not significant and might be masked by the variability of the measured data. This study represents a first step of a clinical application aiming at analysing the mechanical response of normal cervical tissue at different gestational ages, and identifying the mechanical properties that characterize pathologic conditions such as cervical insufficiency leading to preterm delivery.

Entities:  

Mesh:

Year:  2005        PMID: 16143559     DOI: 10.1016/j.media.2005.06.001

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  22 in total

1.  Robotic palpation and mechanical property characterization for abnormal tissue localization.

Authors:  Bummo Ahn; Yeongjin Kim; Cheol Kyu Oh; Jung Kim
Journal:  Med Biol Eng Comput       Date:  2012-07-07       Impact factor: 2.602

2.  Pressure-dependent hydrometra dimensions in hysteroscopy.

Authors:  Michael Bajka; Stephan Weiss; Juerg Kunz; Hans Fischer; Gábor Székely; Peter Niederer
Journal:  Surg Endosc       Date:  2008-12-06       Impact factor: 4.584

3.  Effect of depth on shear-wave elastography estimated in the internal and external cervical os during pregnancy.

Authors:  Edgar Hernandez-Andrade; Alma Aurioles-Garibay; Maynor Garcia; Steven J Korzeniewski; Alyse G Schwartz; Hyunyoung Ahn; Alicia Martinez-Varea; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2014-09       Impact factor: 1.901

Review 4.  The mechanical role of the cervix in pregnancy.

Authors:  Kristin M Myers; Helen Feltovich; Edoardo Mazza; Joy Vink; Michael Bajka; Ronald J Wapner; Timothy J Hall; Michael House
Journal:  J Biomech       Date:  2015-03-11       Impact factor: 2.712

5.  Analyzing three-dimensional ultrastructure of human cervical tissue using optical coherence tomography.

Authors:  Yu Gan; Wang Yao; Kristin M Myers; Joy Y Vink; Ronald J Wapner; Christine P Hendon
Journal:  Biomed Opt Express       Date:  2015-03-03       Impact factor: 3.732

6.  System-level biomechanical approach for the evaluation of term and preterm pregnancy maintenance.

Authors:  Hussam Mahmoud; Amy Wagoner Johnson; Edward K Chien; Michael J Poellmann; Barbara McFarlin
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

7.  Biomechanical pregnant pelvic system model and numerical simulation of childbirth: impact of delivery on the uterosacral ligaments, preliminary results.

Authors:  J Lepage; C Jayyosi; P Lecomte-Grosbras; M Brieu; C Duriez; M Cosson; C Rubod
Journal:  Int Urogynecol J       Date:  2014-09-17       Impact factor: 2.894

8.  Strain at the internal cervical os assessed with quasi-static elastography is associated with the risk of spontaneous preterm delivery at ≤34 weeks of gestation.

Authors:  Edgar Hernandez-Andrade; Maynor Garcia; Hyunyoung Ahn; Steven J Korzeniewski; Homam Saker; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2015-11       Impact factor: 1.901

9.  Cervical strain determined by ultrasound elastography and its association with spontaneous preterm delivery.

Authors:  Edgar Hernandez-Andrade; Roberto Romero; Steven J Korzeniewski; Hyunyoung Ahn; Alma Aurioles-Garibay; Maynor Garcia; Alyse G Schwartz; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan
Journal:  J Perinat Med       Date:  2014-03       Impact factor: 1.901

10.  Evaluation of cervical stiffness during pregnancy using semiquantitative ultrasound elastography.

Authors:  E Hernandez-Andrade; S S Hassan; H Ahn; S J Korzeniewski; L Yeo; T Chaiworapongsa; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2013-01-08       Impact factor: 7.299

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.