Literature DB >> 16132987

Particle migration and gap healing around trabecular metal implants.

O Rahbek1, S Kold, B Zippor, S Overgaard, K Søballe.   

Abstract

Bone on-growth and peri-implant migration of polyethylene particles were studied in an experimental setting using trabecular metal and solid metal implants. Cylindrical implants of trabecular tantalum metal and solid titanium alloy implants with a glass bead blasted surface were inserted either in an exact surgical fit or with a peri-implant gap into a canine knee joint. We used a randomised paired design. Polyethylene particles were injected into the knee joint. In both types of surgical fit we found that the trabecular metal implants had superior bone ongrowth in comparison with solid metal implants (exact fit: 23% vs. 7% [p=0.02], peri-implant gap: 13% vs. 0% [p=0.02]. The number of peri-implant polyethylene particles was significantly reduced around the trabecular metal implants with a peri-implant gap compared with solid implants.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16132987      PMCID: PMC2231580          DOI: 10.1007/s00264-005-0008-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  30 in total

1.  Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial.

Authors:  J D Bobyn; G J Stackpool; S A Hacking; M Tanzer; J J Krygier
Journal:  J Bone Joint Surg Br       Date:  1999-09

2.  Intracapsular pressure and loosening of hip prostheses. Preoperative measurements in 18 hips.

Authors:  O Robertsson; H Wingstrand; U Kesteris; K Jonsson; R Onnerfält
Journal:  Acta Orthop Scand       Date:  1997-06

3.  Short periods of oscillating fluid pressure directed at a titanium-bone interface in rabbits lead to bone lysis.

Authors:  H van der Vis; P Aspenberg; R de Kleine; W Tigchelaar; C J van Noorden
Journal:  Acta Orthop Scand       Date:  1998-02

4.  Reamed surface topography and component seating in press-fit cementless acetabular fixation.

Authors:  Y S Kim; T D Brown; D R Pedersen; J J Callaghan
Journal:  J Arthroplasty       Date:  1995-11       Impact factor: 4.757

5.  Ti-6Al-4V ion solution inhibition of osteogenic cell phenotype as a function of differentiation timecourse in vitro.

Authors:  G J Thompson; D A Puleo
Journal:  Biomaterials       Date:  1996-10       Impact factor: 12.479

Review 6.  Use of mass spectrometry for characterising microbial communities in bioaerosols.

Authors:  B Szponar; L Larsson
Journal:  Ann Agric Environ Med       Date:  2001       Impact factor: 1.447

7.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

8.  Sealing effect of hydroxyapatite coating: a 12-month study in canines.

Authors:  O Rahbek; S Overgaard; T B Jensen; K Bendix; K Søballe
Journal:  Acta Orthop Scand       Date:  2000-12

9.  Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro.

Authors:  T R Green; J Fisher; M Stone; B M Wroblewski; E Ingham
Journal:  Biomaterials       Date:  1998-12       Impact factor: 12.479

10.  The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris.

Authors:  J D Bobyn; J J Jacobs; M Tanzer; R M Urban; R Aribindi; D R Sumner; T M Turner; C E Brooks
Journal:  Clin Orthop Relat Res       Date:  1995-02       Impact factor: 4.176

View more
  11 in total

1.  Limb-sparing surgery using tantalum metal endoprosthesis in a dog with osteosarcoma of the distal radius.

Authors:  Tamara L MacDonald; Teresa D Schiller
Journal:  Can Vet J       Date:  2010-05       Impact factor: 1.008

2.  Multicentre use of a porous tantalum monoblock acetabular component.

Authors:  Th A Xenakis; G A Macheras; K S Stafilas; A T Kostakos; K Bargiotas; K N Malizos
Journal:  Int Orthop       Date:  2008-05-29       Impact factor: 3.075

3.  Bone remodelling around HA-coated acetabular cups : a DEXA study with a 3-year follow-up in a randomised trial.

Authors:  M B Laursen; P T Nielsen; K Søballe
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

4.  Arthrotomy-based preclinical models of particle-induced osteolysis: A systematic review.

Authors:  Meghan M Moran; Brittany M Wilson; Ryan D Ross; Amarjit S Virdi; Dale Rick Sumner
Journal:  J Orthop Res       Date:  2017-06-28       Impact factor: 3.494

5.  Basic science considerations in primary total hip replacement arthroplasty.

Authors:  Saqeb B Mirza; Douglas G Dunlop; Sukhmeet S Panesar; Syed G Naqvi; Shafat Gangoo; Saif Salih
Journal:  Open Orthop J       Date:  2010-05-11

6.  Relationship between solute transport properties and tissue morphology in human annulus fibrosus.

Authors:  Francesco Travascio; Alicia R Jackson; Mark D Brown; Wei Yong Gu
Journal:  J Orthop Res       Date:  2009-12       Impact factor: 3.494

7.  Trabecular metal tibia still stable at 5 years: an RSA study of 36 patients aged less than 60 years.

Authors:  Anders Henricson; Dan Rösmark; Kjell G Nilsson
Journal:  Acta Orthop       Date:  2013-05-13       Impact factor: 3.717

8.  Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh: a randomized clinical RSA study on cementless tibial components.

Authors:  Maiken Stilling; Frank Madsen; Anders Odgaard; Lone Rømer; Niels Trolle Andersen; Ole Rahbek; Kjeld Søballe
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

9.  Trabecular metal tibial knee component still stable at 10 years.

Authors:  Anders Henricson; Kjell G Nilsson
Journal:  Acta Orthop       Date:  2016-06-30       Impact factor: 3.717

10.  Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study.

Authors:  De-Yong Huang; Liang Zhang; Yi-Xin Zhou; Chun-Yu Zhang; Hui Xu; Yong Huang
Journal:  Chin Med J (Engl)       Date:  2016-04-20       Impact factor: 2.628

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.