Literature DB >> 8776051

Reamed surface topography and component seating in press-fit cementless acetabular fixation.

Y S Kim1, T D Brown, D R Pedersen, J J Callaghan.   

Abstract

Thirty-eight paired, size-matched, fresh-frozen cadaver acetabulae were used to study reamed surface topography and the seating of on-line versus oversized noncemented components. Four commonly used constructs were considered: on-line reamed and 2-mm oversized hemispherical cups, and on-line reamed and 1-mm oversized dual-radius cups. Reamed surface topography was indexed by three-dimensional surfaces mathematically fitted to digitized castings. Component seating was indexed by the distribution of bone-cup contact and the thickness of the gap between the component backing and the bone. The reamed surfaces were better approximated by slightly blunt ellipsoids than by spheres, especially for the smaller acetabulae. Seating of the on-line hemispherical cups was best near the pole and poorest near the equator, whereas the converse was true for the 1-mm oversized dual-radius cups. The on-line dual-radius cups offered better overall compromise between polar and equatorial contact than did the 2-mm oversized hemispherical components.

Mesh:

Year:  1995        PMID: 8776051     DOI: 10.1016/s0883-5403(05)80226-8

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Deformation of metal-backed acetabular components and the impact of liner thickness in a cadaveric model.

Authors:  David Markel; Judd Day; Ryan Siskey; Imants Liepins; Steven Kurtz; Kevin Ong
Journal:  Int Orthop       Date:  2010-07-13       Impact factor: 3.075

2.  Particle migration and gap healing around trabecular metal implants.

Authors:  O Rahbek; S Kold; B Zippor; S Overgaard; K Søballe
Journal:  Int Orthop       Date:  2005-08-31       Impact factor: 3.075

3.  Validation of FE micromotions and strains around a press-fit cup: introducing a new micromotion measuring technique.

Authors:  S G Clarke; A T M Phillips; A M J Bull
Journal:  Ann Biomed Eng       Date:  2012-02-16       Impact factor: 3.934

4.  Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.

Authors:  Tomonori Tabata; Nobuhiro Kaku; Katsutoshi Hara; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-11-25

5.  Hemispherical and minimally invasive total hip reamers: a biomechanical analysis of use and design.

Authors:  Steven Slotkin; Nicholas B Frisch; Gilbert Roc; Craig D Silverton
Journal:  Arthroplast Today       Date:  2016-10-10

6.  Laser Resonance Frequency Analysis: A Novel Measurement Approach to Evaluate Acetabular Cup Stability During Surgery.

Authors:  Shunsuke Kikuchi; Katsuhiro Mikami; Daisuke Nakashima; Toshiyuki Kitamura; Noboru Hasegawa; Masaharu Nishikino; Arihiko Kanaji; Masaya Nakamura; Takeo Nagura
Journal:  Sensors (Basel)       Date:  2019-11-08       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.