Literature DB >> 16132932

Prospective evaluation of two different injection techniques for MR arthrography of the hip.

Sylvain R Duc1, Juerg Hodler, Marius R Schmid, Marco Zanetti, Bernard Mengiardi, Claudio Dora, Christian W A Pfirrmann.   

Abstract

The aim of the study was to evaluate prospectively the technical feasibility and discomfort of two different injection techniques for MR arthrography of the hip. Sixty-one consecutive patients undergoing MR arthrography of the hip (68 hips) were randomly injected either at the femoral head (36 hips) or the femoral neck (32 hips). The patients rated discomfort during and 0-72 h after arthrography using a visual analogue scale (VAS, 0="did not feel anything", 100="unbearable"). The volume injected, the distance between the needle tract and the neurovascular bundle, the duration of the procedure and the extra-articular contrast leakage were measured. No significant differences were found for the volume injected, the distance between the needle tract and the neurovascular bundle, or the procedure duration. Volume of extra-articular contrast leakage was statistically significantly different (head 1+/-2 cm(3), neck 3+/-5 cm(3), P=0.024). The VAS score for needle advancement was significantly different (head 25+/-20, neck 19+/-23, P=0.031). No significant differences were found for the VAS score regarding delayed discomfort. Before the examination the arthrography-related discomfort was overestimated by 74% (50/68), correctly anticipated by 22% (15/68) and underestimated by 4% (3/68) of the patients. MR-related discomfort was overestimated by 32% (22/68), correctly anticipated by 57% (39/68) and underestimated by 10% (7/68) of the patients. Both hip puncture techniques were well tolerated. The neck injection technique produced less discomfort and was associated with greater extra-articular contrast leakage.

Entities:  

Mesh:

Year:  2005        PMID: 16132932     DOI: 10.1007/s00330-005-2865-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  23 in total

1.  Surgical dislocation of the adult hip a technique with full access to the femoral head and acetabulum without the risk of avascular necrosis.

Authors:  R Ganz; T J Gill; E Gautier; K Ganz; N Krügel; U Berlemann
Journal:  J Bone Joint Surg Br       Date:  2001-11

2.  A further anatomical check on the accuracy of intra-articular hip injections in relation to the therapy of coxarthritis.

Authors:  M M DOBSON
Journal:  Ann Rheum Dis       Date:  1950-09       Impact factor: 19.103

3.  A technique for arthrography of the hip.

Authors:  A KENIN; J LEVINE
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1952-07

4.  Modified technique for fluid aspiration from the hip in patients with prosthetic hips.

Authors:  E A Brandser; G Y El-Khoury; R L FitzRandolph
Journal:  Radiology       Date:  1997-08       Impact factor: 11.105

5.  -Arthrography of the hip-.

Authors:  L Bellaiche; M Wybier; P Champsaur
Journal:  Ann Radiol (Paris)       Date:  1997

6.  Controlled arthrography of the hip: a technic of fluoroscopic monitoring and recording.

Authors:  M B Ozonoff
Journal:  Clin Orthop Relat Res       Date:  1973-06       Impact factor: 4.176

7.  Arthrography for complications of total hip replacement. A review of thirty-one arthrograms.

Authors:  E A Salvati; R H Freiberger; P D Wilson
Journal:  J Bone Joint Surg Am       Date:  1971-06       Impact factor: 5.284

8.  Arthrography of the hip joint.

Authors:  A B Goldman
Journal:  Crit Rev Diagn Imaging       Date:  1980

9.  Patient perception of magnetic resonance arthrography.

Authors:  M I Robbins; K F Anzilotti; L D Katz; R C Lange
Journal:  Skeletal Radiol       Date:  2000-05       Impact factor: 2.199

10.  Hip arthrography in infants and children: the inferomedial approach.

Authors:  J L Strife; R Towbin; A Crawford
Journal:  Radiology       Date:  1984-08       Impact factor: 11.105

View more
  13 in total

Review 1.  Ultrasound-guided joint injections for MR arthrography in pediatric patients: how we do it.

Authors:  Jeffrey Otjen; Shawn E Parnell; Sarah Menashe; Mahesh M Thapa
Journal:  Pediatr Radiol       Date:  2015-03-01

Review 2.  Hip pain in adults: MR imaging appearance of common causes.

Authors:  Bernard Mengiardi; Christian W A Pfirrmann; Juerg Hodler
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

Review 3.  [Magnetic resonance imaging in orthopaedic medicine].

Authors:  R Straub; M G Mack; V Jacobi; D Proschek; T J Vogl
Journal:  Orthopade       Date:  2006-06       Impact factor: 1.087

Review 4.  Technical errors in MR arthrography.

Authors:  Juerg Hodler
Journal:  Skeletal Radiol       Date:  2007-05-26       Impact factor: 2.199

5.  Shoulder, hip, and knee arthrography needle placement using fluoroscopic guidance: practice patterns of musculoskeletal radiologists in North America.

Authors:  Conor P Shortt; William B Morrison; Catherine C Roberts; Diane M Deely; Angela G Gopez; Adam C Zoga
Journal:  Skeletal Radiol       Date:  2009-01-30       Impact factor: 2.199

6.  Diagnostic and therapeutic joint injections.

Authors:  Salvatore Masala; Roberto Fiori; Dario Alberto Bartolucci; Matteo Mammucari; Giorgios Angelopoulos; Francesco Massari; Giovanni Simonetti
Journal:  Semin Intervent Radiol       Date:  2010-06       Impact factor: 1.513

7.  MR findings associated with positive distraction of the hip joint achieved by axial traction.

Authors:  Aline Suter; Tobias J Dietrich; Matthias Maier; Claudio Dora; Christian W A Pfirrmann
Journal:  Skeletal Radiol       Date:  2015-01-27       Impact factor: 2.199

8.  Ultrasound-guided injection for MR arthrography of the hip: comparison of two different techniques.

Authors:  Fatih Kantarci; Mustafa Ozbayrak; Fatih Gulsen; Mert Gencturk; Huseyin Botanlioglu; Ismail Mihmanli
Journal:  Skeletal Radiol       Date:  2011-10-14       Impact factor: 2.199

9.  MR arthrography of the shoulder: tolerance evaluation of four different injection techniques.

Authors:  Evangelos Perdikakis; Eleni Drakonaki; Thomas Maris; Apostolos Karantanas
Journal:  Skeletal Radiol       Date:  2012-10-14       Impact factor: 2.199

Review 10.  Musculoskeletal aspiration procedures.

Authors:  Barry Glenn Hansford; Gregory Scott Stacy
Journal:  Semin Intervent Radiol       Date:  2012-12       Impact factor: 1.513

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.