OBJECTIVE: The purpose of this study was to prospectively evaluate the two different ultrasound-guided injection techniques for MR arthrography of the hip. MATERIALS AND METHODS:Fifty-nine consecutive patients (21 men, 38 women) referred for MR arthrographies of the hip were prospectively included in the study. Three patients underwent bilateral MR arthrography. The two injection techniques were quantitatively and qualitatively compared. Quantitative analysis was performed by the comparison of injected contrast material volume into the hip joint. Qualitative analysis was performed with regard to extraarticular leakage of contrast material into the soft tissues. Extraarticular leakage of contrast material was graded as none, minimal, moderate, or severe according to the MR images. Each patient rated discomfort after the procedure using a visual analogue scale (VAS). RESULTS: The injected contrast material volume was less in femoral head puncture technique (mean 8.9 ± 3.4 ml) when compared to femoral neck puncture technique (mean 11.2 ± 2.9 ml) (p < 0.05). The chi-squared test showed significantly more contrast leakage by femoral head puncture technique (p < 0.05). Statistical analysis showed no difference between the head and neck puncture groups in terms of feeling of pain (p = 0.744) or in the body mass index (p = 0.658) of the patients. CONCLUSION: The femoral neck injection technique provides high intraarticular contrast volume and produces less extraarticular contrast leakage than the femoral head injection technique when US guidance is used for MR arthrography of the hip.
RCT Entities:
OBJECTIVE: The purpose of this study was to prospectively evaluate the two different ultrasound-guided injection techniques for MR arthrography of the hip. MATERIALS AND METHODS: Fifty-nine consecutive patients (21 men, 38 women) referred for MR arthrographies of the hip were prospectively included in the study. Three patients underwent bilateral MR arthrography. The two injection techniques were quantitatively and qualitatively compared. Quantitative analysis was performed by the comparison of injected contrast material volume into the hip joint. Qualitative analysis was performed with regard to extraarticular leakage of contrast material into the soft tissues. Extraarticular leakage of contrast material was graded as none, minimal, moderate, or severe according to the MR images. Each patient rated discomfort after the procedure using a visual analogue scale (VAS). RESULTS: The injected contrast material volume was less in femoral head puncture technique (mean 8.9 ± 3.4 ml) when compared to femoral neck puncture technique (mean 11.2 ± 2.9 ml) (p < 0.05). The chi-squared test showed significantly more contrast leakage by femoral head puncture technique (p < 0.05). Statistical analysis showed no difference between the head and neck puncture groups in terms of feeling of pain (p = 0.744) or in the body mass index (p = 0.658) of the patients. CONCLUSION: The femoral neck injection technique provides high intraarticular contrast volume and produces less extraarticular contrast leakage than the femoral head injection technique when US guidance is used for MR arthrography of the hip.
Authors: E Qvistgaard; H Kristoffersen; L Terslev; B Danneskiold-Samsøe; S Torp-Pedersen; H Bliddal Journal: Osteoarthritis Cartilage Date: 2001-08 Impact factor: 6.576
Authors: Sylvain R Duc; Juerg Hodler; Marius R Schmid; Marco Zanetti; Bernard Mengiardi; Claudio Dora; Christian W A Pfirrmann Journal: Eur Radiol Date: 2005-08-16 Impact factor: 5.315
Authors: G Schulte-Altedorneburg; M Gebhard; W A Wohlgemuth; W Fischer; J Zentner; R Wegener; T Balzer; K Bohndorf Journal: Skeletal Radiol Date: 2002-12-05 Impact factor: 2.199
Authors: Carmelo Messina; Giuseppe Banfi; Alberto Aliprandi; Giovanni Mauri; Francesco Secchi; Francesco Sardanelli; Luca Maria Sconfienza Journal: Eur Radiol Date: 2015-08-08 Impact factor: 5.315
Authors: Nadja A Farshad-Amacker; Till Bay; Andrea B Rosskopf; José M Spirig; Florian Wanivenhaus; Christian W A Pfirrmann; Mazda Farshad Journal: Eur Radiol Exp Date: 2020-02-04