Literature DB >> 16132923

Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study.

Andreas H Mahnken1, Georg Mühlenbruch, Ralf Koos, Marco Das, Saskia Pohl, Sven Stanzel, Rolf W Günther, Joachim E Wildberger.   

Abstract

The purpose of this study is to asses the impact of small field-of-view (FOV) sizes on the detection of coronary artery calcifications using multislice-spiral computed tomography (MSCT). First, a static chest phantom containing calcium inserts was scanned 10 times using a standardized scan protocol. Secondly, 50 patients (28 male, 63.6+/-10.6 years) underwent cardiac MSCT using the same protocol. Images were reconstructed with three different FOV sizes (180x180, 220x220, 380x380 mm(2)). Coronary calcium scoring and risk stratification were performed for each image series. In the phantom study, the Agatston score calculated with a FOV size of 180x180 mm(2) was 657.80+/-20.05. At a FOV of 220x220 mm(2) and 380x380 mm(2), the corresponding values were 657.04+/-21.36 and 655.04+/-20.74, respectively. The corresponding values in the patient study were 541.65+/-869.87, 541.91+/-872.57 and 536.61+/-867.81. No statistically significant differences in the calcium score were found comparing different FOV sizes. Significantly more lesions (p=0.00149) were detected in the patient study. Comparing the different FOV sizes of 180x180 mm(2) and 220x220 mm(2) (380x380 mm(2)), four (six) patients had to be assigned to different risk groups. The use of small FOV sizes resulted in an improved detection of coronary calcifications influencing the risk stratification for further cardiac events in MSCT coronary calcium scoring.

Entities:  

Mesh:

Year:  2005        PMID: 16132923     DOI: 10.1007/s00330-005-2881-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  Coronary artery calcium measurement: agreement of multirow detector and electron beam CT.

Authors:  C R Becker; T Kleffel; A Crispin; A Knez; J Young; U J Schoepf; R Haberl; M F Reiser
Journal:  AJR Am J Roentgenol       Date:  2001-05       Impact factor: 3.959

2.  Coronary artery calcium measurement with multi-detector row CT: in vitro assessment of effect of radiation dose.

Authors:  Cheng Hong; Kyongtae T Bae; Thomas K Pilgram; Jongdae Suh; David Bradley
Journal:  Radiology       Date:  2002-12       Impact factor: 11.105

3.  Coronary calcium scoring: modelling, predicting and correcting for the effect of CT scanner spatial resolution on Agatston and volume scores.

Authors:  Leon Kaufman; Mikhail Mineyev; Joseph Carlson; David Goldhaber; John Rumberger
Journal:  Phys Med Biol       Date:  2003-05-21       Impact factor: 3.609

4.  Quantification of coronary artery calcium with multi-detector row CT: assessing interscan variability with different tube currents pilot study.

Authors:  Naoki Takahashi; Kyongtae T Bae
Journal:  Radiology       Date:  2003-07       Impact factor: 11.105

5.  Variation of the coronary calcium score depending on image reconstruction interval and scoring algorithm.

Authors:  Andreas H Mahnken; Joachim E Wildberger; Anil M Sinha; Thomas Flohr; Huu T Truong; Gabriele A Krombach; Rolf W Gunther
Journal:  Invest Radiol       Date:  2002-09       Impact factor: 6.016

6.  Quantification of coronary artery calcium using ultrafast computed tomography.

Authors:  A S Agatston; W R Janowitz; F J Hildner; N R Zusmer; M Viamonte; R Detrano
Journal:  J Am Coll Cardiol       Date:  1990-03-15       Impact factor: 24.094

7.  Sensitivity to detect small coronary artery calcium lesions with varying slice thickness using electron beam tomography.

Authors:  Songshou Mao; Janis Child; Sivi Carson; Steve C K Liu; Ronald J Oudiz; Matthew J Budoff
Journal:  Invest Radiol       Date:  2003-03       Impact factor: 6.016

8.  Determination of coronary calcium with multi-slice spiral computed tomography: a comparative study with electron-beam CT.

Authors:  Andreas Knez; Christoph Becker; Alexander Becker; Alexander Leber; Carl White; Maximilian Reiser; Gerhard Steinbeck
Journal:  Int J Cardiovasc Imaging       Date:  2002-08       Impact factor: 2.357

9.  Prognostic value of coronary calcification and angiographic stenoses in patients undergoing coronary angiography.

Authors:  R Detrano; T Hsiai; S Wang; G Puentes; J Fallavollita; P Shields; W Stanford; C Wolfkiel; D Georgiou; M Budoff; J Reed
Journal:  J Am Coll Cardiol       Date:  1996-02       Impact factor: 24.094

10.  Is coronary artery calcium mass related to Agatston score?

Authors:  Cheng Hong; Thomas K Pilgram; Fang Zhu; Kyongtae T Bae
Journal:  Acad Radiol       Date:  2004-03       Impact factor: 3.173

View more
  6 in total

1.  The accuracy of 1- and 3-mm slices in coronary calcium scoring using multi-slice CT in vitro and in vivo.

Authors:  Georg Mühlenbruch; Ernst Klotz; Joachim E Wildberger; Ralf Koos; Marco Das; Matthias Niethammer; Christian Hohl; Dagmar Honnef; Christoph Thomas; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2006-07-04       Impact factor: 5.315

2.  Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease.

Authors:  Marc Dewey; Bernd Hamm
Journal:  Eur Radiol       Date:  2006-10-10       Impact factor: 5.315

3.  Evaluation of automated attenuation-based tube current adaptation for coronary calcium scoring in MDCT in a cohort of 262 patients.

Authors:  Georg Mühlenbruch; Christian Hohl; Marco Das; Joachim E Wildberger; Christoph Suess; Ernst Klotz; Thomas Flohr; Ralf Koos; Christoph Thomas; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2007-02-17       Impact factor: 5.315

4.  Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom.

Authors:  Philipp G C Begemann; Udo van Stevendaal; Ralph Koester; Andreas H Mahnken; Andreas Koops; Gerhard Adam; Michael Grass; Claus Nolte-Ernsting
Journal:  Eur Radiol       Date:  2007-02-01       Impact factor: 7.034

5.  Measurement of coronary calcium scores by electron beam computed tomography or exercise testing as initial diagnostic tool in low-risk patients with suspected coronary artery disease.

Authors:  Christiane A Geluk; Riksta Dikkers; Patrick J Perik; René A Tio; Marco J W Götte; Hans L Hillege; Rozemarijn Vliegenthart; Janneke B Houwers; Tineke P Willems; Matthijs Oudkerk; Felix Zijlstra
Journal:  Eur Radiol       Date:  2007-09-28       Impact factor: 5.315

6.  Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

Authors:  Abbas Shokri; Leila Ramezani; Mohsen Bidgoli; Mahdi Akbarzadeh; Karim Ghazikhanlu-Sani; Hamed Fallahi-Sichani
Journal:  Imaging Sci Dent       Date:  2018-03-19
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.