Variation of the coronary calcium score depending on image reconstruction interval and scoring algorithm.

Andreas H Mahnken1, Joachim E Wildberger, Anil M Sinha, Thomas Flohr, Huu T Truong, Gabriele A Krombach, Rolf W Gunther.   

Abstract

RATIONALE AND
OBJECTIVES: To evaluate the reconstruction interval dependent bandwidth of the coronary calcium score, considering different methods of image reconstruction and quantification of coronary calcifications.
MATERIALS AND METHODS: Seventy-five patients underwent coronary calcium scoring by use of retrospectively ECG-gated multislice spiral CT. In all patients overlapping and nonoverlapping image reconstruction was performed every 10% of the RR-interval. Coronary calcium score was calculated for every reconstructed image series using the Agatston score and a volumetric scoring method. In 25 patients the analysis was performed twice to determine the reconstruction interval dependent intraobserver variability.
RESULTS: For nonoverlapping image reconstruction the median of the calcium score determined by the Agatston method ranged from 125.8 to 216.2 and from 166.9 to 211.7 for the volumetric scoring method. For overlapping image reconstruction the corresponding values ranged from 91.6 to 160.5 for the Agatston score and 128.3 to 175.3 for the volumetric calcium score. Reconstruction interval dependent median (mean) variation of the coronary calcium score ranged from 24.1 (45.5)% for nonoverlapping image reconstruction using the Agatston score to 17.5 (25.2)% utilizing a volumetric calcium score with overlapping image reconstruction. There was no statistical significant (P< 0.05) difference between the different methods. Intraobserver variability for the different image reconstruction intervals ranged from 0.78% to 21.51%. The least intraobserver variability was found for overlapping image reconstruction during the diastole using the volumetric scoring method.
CONCLUSIONS: Diastolic image reconstruction at 50% or 60% of the RR-interval is recommendable for retrospectively ECG-gated multislice spiral CT. Volumetric calcium scoring and overlapping image reconstruction are beneficial to reduce the variation of the coronary calcium score.

Entities:  

Mesh:

Year:  2002        PMID: 12218445     DOI: 10.1097/00004424-200209000-00004

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  The accuracy of 1- and 3-mm slices in coronary calcium scoring using multi-slice CT in vitro and in vivo.

Authors:  Georg Mühlenbruch; Ernst Klotz; Joachim E Wildberger; Ralf Koos; Marco Das; Matthias Niethammer; Christian Hohl; Dagmar Honnef; Christoph Thomas; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2006-07-04       Impact factor: 5.315

2.  Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study.

Authors:  Andreas H Mahnken; Georg Mühlenbruch; Ralf Koos; Marco Das; Saskia Pohl; Sven Stanzel; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2005-08-20       Impact factor: 5.315

3.  The impact of motion artifacts on the reproducibility of repeated coronary artery calcium measurements.

Authors:  Jun Horiguchi; Hiroshi Fukuda; Hideya Yamamoto; Nobuhiko Hirai; Farzana Alam; Hideaki Kakizawa; Masashi Hieda; Toshihiro Tachikake; Kazushi Marukawa; Katsuhide Ito
Journal:  Eur Radiol       Date:  2006-05-23       Impact factor: 5.315

4.  Fully automated derivation of coronary artery calcium scores and cardiovascular risk assessment from contrast medium-enhanced coronary CT angiography studies.

Authors:  Ullrich Ebersberger; Dov Eilot; Roman Goldenberg; Alon Lev; J Reid Spears; Garrett W Rowe; Nicholas Y Gallagher; William T Halligan; Philipp Blanke; Marcus R Makowski; Aleksander W Krazinski; Justin R Silverman; Fabian Bamberg; Alexander W Leber; Ellen Hoffmann; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2012-09-16       Impact factor: 5.315

5.  Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom.

Authors:  Philipp G C Begemann; Udo van Stevendaal; Ralph Koester; Andreas H Mahnken; Andreas Koops; Gerhard Adam; Michael Grass; Claus Nolte-Ernsting
Journal:  Eur Radiol       Date:  2007-02-01       Impact factor: 7.034

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.