Literature DB >> 16120035

Invasiveness as a barrier to self-monitoring of blood glucose in diabetes.

Julie Wagner1, Carl Malchoff, Gina Abbott.   

Abstract

BACKGROUND: This study investigated the degree to which the invasive characteristic of glucose monitoring is a barrier to self-monitoring of blood glucose (SMBG).
METHODS: A paper-and-pencil Measure of Invasiveness as a reason for Skipping SMBG (MISS) was created and administered to 339 people with diabetes. The correlations between MISS scores and actual SMBG frequency, percent adherence to SMBG recommendations, SMBG anxiety, SMBG burden, and knowledge of the importance of glycemic control for avoiding diabetes complications were each explored.
RESULTS: On a scale of 0-28, the average MISS score was M = 4.3 (SD = 5.4, range 0-28). Fully 63% (nearly two-thirds) of respondents reported skipping SMBG because of the invasiveness of the procedure. MISS scores were negatively related to percent adherence to healthcare provider SMBG recommendations as measured by memory function of automated meters (Spearman's r= -0.47, P < 0.01). MISS scores were also negatively related to absolute SMBG frequency regardless of SMBG recommendations (Spearman's r= -0.11, P < 0.05). Correlation between the MISS and SMBG anxiety was significant (Spearman's r = 0.50, P < 0.01). With highly anxious participants deleted, the magnitude of the correlation was attenuated, but persisted (Spearman's r = 0.28, P < 0.01), suggesting that invasiveness is associated with SMBG anxiety even among patients without a blood or injection phobia. MISS scores were also correlated with the degree to which patients find routine and non-routine SMBG checks a burden (routine r = 0.38, P < 0.01; non-routine r = 0.45, P < 0.01). Results of Mann-Whitney U tests indicated higher MISS scores among participants with less knowledge about the importance of glycemic control in the development of diabetes vascular complications.
CONCLUSIONS: Invasiveness is a common and serious barrier to SMBG. These findings suggest that people with diabetes would perform SMBG more frequently and have improved quality of life with non-invasive SMBG.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16120035     DOI: 10.1089/dia.2005.7.612

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  26 in total

1.  A disposable tear glucose biosensor-part 1: design and concept testing.

Authors:  Daniel K Bishop; Jeffrey T La Belle; Stephen R Vossler; Dharmendra R Patel; Curtiss B Cook
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

2.  Dose accuracy and injection force of disposable pens delivering pramlintide for the treatment of diabetes.

Authors:  Douglas Merritt; Barb Schreiner; Scott Harris; Mary Beth DeYoung; Susan Strobel; Joseph Lauinger
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

3.  Mobile phone-based video messages for diabetes self-care support.

Authors:  Amanda M Bell; Stephanie J Fonda; M Susan Walker; Virginia Schmidt; Robert A Vigersky
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

4.  Decisions in the Psychology of Glucose Monitoring.

Authors:  Gérard Reach
Journal:  J Diabetes Sci Technol       Date:  2019-06-14

5.  Lifetime depression and diabetes self-management in women with Type 2 diabetes: a case-control study.

Authors:  J A Wagner; H Tennen; C Y Osborn
Journal:  Diabet Med       Date:  2010-06       Impact factor: 4.359

6.  Noninvasive glucose monitoring: increasing accuracy by combination of multi-technology and multi-sensors.

Authors:  Ilana Harman-Boehm; Avner Gal; Alexander M Raykhman; Eugene Naidis; Yulia Mayzel
Journal:  J Diabetes Sci Technol       Date:  2010-05-01

7.  Evaluation of a New Noninvasive Glucose Monitoring Device by Means of Standardized Meal Experiments.

Authors:  Andreas Pfützner; Stephanie Strobl; Filiz Demircik; Lisa Redert; Johannes Pfützner; Anke H Pfützner; Alexander Lier
Journal:  J Diabetes Sci Technol       Date:  2018-02-16

8.  A Disposable Tear Glucose Biosensor-Part 4: Preliminary Animal Model Study Assessing Efficacy, Safety, and Feasibility.

Authors:  Jeffrey T La Belle; Erica Engelschall; Kenneth Lan; Pankti Shah; Neil Saez; Stephanie Maxwell; Teagan Adamson; Michelle Abou-Eid; Kenyon McAferty; Dharmendra R Patel; Curtiss B Cook
Journal:  J Diabetes Sci Technol       Date:  2014-01-01

9.  A systematic review of patient-reported measures of burden of treatment in three chronic diseases.

Authors:  David T Eton; Tarig A Elraiyah; Kathleen J Yost; Jennifer L Ridgeway; Anna Johnson; Jason S Egginton; Rebecca J Mullan; Mohammad Hassan Murad; Patricia J Erwin; Victor M Montori
Journal:  Patient Relat Outcome Meas       Date:  2013-06-05

10.  Encapsulation of FITC to monitor extracellular pH: a step towards the development of red blood cells as circulating blood analyte biosensors.

Authors:  Sarah C Ritter; Mark A Milanick; Kenith E Meissner
Journal:  Biomed Opt Express       Date:  2011-06-22       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.