Positive effect of early loading on implant stability in the bi-cortical guinea-pig model.

Els De Smet1, Siegfried Jaecques, Katleen Vandamme, Jos Vander Sloten, Ignace Naert.   

Abstract

Loading, early after implant placement, has gained rapid interest in dentistry. Primary implant stability, as e.g. defined by resonance frequency instrumentation, has been isolated as a predicator when immediate and early implant loading is applied. The aim of this study was to investigate the effect of early (after 7 days) mechanical loading on the establishment of osseointegration by means of resonance frequency analysis (RFA). Percutaneous titanium implants were installed in both tibiae of 10 guinea-pigs. One week after implant installation, one implant (test) was loaded daily for 6 weeks, while the contra-lateral served as the unloaded one (control). A sinusoidally varying bending moment was applied at a frequency of 3 Hz and a force amplitude of 5 N, for 1800 cycli. Resonance frequency was measured at implant installation and from then on weekly using the RFA-device (Osstell). Contrary to control implants, that showed a decrease in stability 1 week after installation, reaching a minimum at 3 weeks (-200 Hz), test implants showed a progressive increase in stability over time. After 6 weeks, the mean resonance frequency of test and control implants reached the same values. As confirmed by recent literature, early loading does not have to endanger the establishment of osseointegration of titanium implants. On the contrary, controlled loading is beneficial to maintain the implant stability during the early critical healing period as determined by RFA-measurements.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16117763     DOI: 10.1111/j.1600-0501.2005.01156.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  10 in total

Review 1.  Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives.

Authors:  Fabio Variola; John B Brunski; Giovanna Orsini; Paulo Tambasco de Oliveira; Rima Wazen; Antonio Nanci
Journal:  Nanoscale       Date:  2010-10-26       Impact factor: 7.790

2.  Progression of bone ingrowth and attachment strength for stability of percutaneous osseointegrated prostheses.

Authors:  Sujee Jeyapalina; J Peter Beck; Roy D Bloebaum; Kent N Bachus
Journal:  Clin Orthop Relat Res       Date:  2014-10       Impact factor: 4.176

3.  Micromotion-induced strain fields influence early stages of repair at bone-implant interfaces.

Authors:  Rima M Wazen; Jennifer A Currey; Hongqiang Guo; John B Brunski; Jill A Helms; Antonio Nanci
Journal:  Acta Biomater       Date:  2013-01-19       Impact factor: 8.947

4.  Effect of decreased implant healing time on bone (re)modeling adjacent to plateaued implants under functional loading in a dog model.

Authors:  Jing Dai; Ning Cheng; Richard J Miron; Bin Shi; Xiangrong Cheng; Yufeng Zhang
Journal:  Clin Oral Investig       Date:  2013-02-03       Impact factor: 3.573

5.  Time course of peri-implant bone regeneration around loaded and unloaded implants in a rat model.

Authors:  Shailly H Jariwala; Hwabok Wee; Evan P Roush; Tiffany L Whitcomb; Christopher Murter; Gery Kozlansky; Akhlesh Lakhtakia; Allen R Kunselman; Henry J Donahue; April D Armstrong; Gregory S Lewis
Journal:  J Orthop Res       Date:  2016-07-20       Impact factor: 3.494

6.  Enhancement of implant osseointegration by high-frequency low-magnitude loading.

Authors:  Xiaolei Zhang; Antonia Torcasio; Katleen Vandamme; Toru Ogawa; G Harry van Lenthe; Ignace Naert; Joke Duyck
Journal:  PLoS One       Date:  2012-07-10       Impact factor: 3.240

7.  Influence of a Novel Surface of Bioactive Implants on Osseointegration: A Comparative and Histomorfometric Correlation and Implant Stability Study in Minipigs.

Authors:  Manuel M Romero-Ruiz; Francisco Javier Gil-Mur; José Vicente Ríos-Santos; Pedro Lázaro-Calvo; Blanca Ríos-Carrasco; Mariano Herrero-Climent
Journal:  Int J Mol Sci       Date:  2019-05-09       Impact factor: 5.923

8.  A randomized clinical study to compare implant stability and bone loss using early loading protocol in two implant systems with different design.

Authors:  Rani Ranabhatt; Kamleshwar Singh; Ramashanker Siddharth; Shuchi Tripathi; Deeksha Arya
Journal:  J Indian Prosthodont Soc       Date:  2021 Jan-Mar

9.  Micro-morphologic changes around biophysically-stimulated titanium implants in ovariectomized rats.

Authors:  Kivanc Akca; Ebru Sarac; Ugur Baysal; Mete Fanuscu; Ting-Ling Chang; Murat Cehreli
Journal:  Head Face Med       Date:  2007-07-16       Impact factor: 2.151

10.  Bone healing response in cyclically loaded implants: Comparing zero, one, and two loading sessions per day.

Authors:  Renan de Barros E Lima Bueno; Ana Paula Dias; Katia J Ponce; Rima Wazen; John B Brunski; Antonio Nanci
Journal:  J Mech Behav Biomed Mater       Date:  2018-05-31
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.