Literature DB >> 16094517

Development of sutureless vascular connecting system for easy implantation of small-caliber artificial grafts.

Osamu Sakai1, Yasuhide Nakayama, Yasushi Nemoto, Yoshihiro Okamoto, Taiji Watanabe, Keiichi Kanda, Hitoshi Yaku.   

Abstract

A novel sutureless vascular connecting system, an assembly with a delivery rod, an introducing sheath, and a connecting device, was developed for easy implantation of small-caliber vascular grafts less than 2 mm in internal diameter. A microporous stainless tube (length 2 mm, external diameter 1.6 mm, wall thickness 65 microm, pore diameter 400 microm, pore-to-pore distance 500 microm) was designed to serve as a connecting device. The feasibility of the system was tested using two types of preliminary animal experiments. One animal model consisted of graft implantation into the rat abdominal aorta (1.5 mm in diameter). The connecting device was inserted into the proximal and distal ends of the aorta through the introducing sheath by pushing the delivery rod with the connecting device placed over it. Subsequently, the aortic segments were inserted into both ends of model grafts made of segmented polyurethane (1.8 mm in internal diameter) and were fixed with banding silk threads from the exterior. The procedure was completed within 20 min without requiring specialized microsurgery techniques. Blood leakage and obstruction did not occur. The second model consisted of an end-to-end anastomosis between rabbit common carotid arteries (2 mm in diameter), which was performed within several minutes of blood flow interruption. Scanning electron microscopy demonstrated that the luminal surface of the device was fully covered with endothelial cells (ECs) after 1 week as a result of transluminal ingrowth of native ECs through the micropores in the device. This endothelialization may prevent early thrombus-induced occlusion. This simple and "easy-to-learn" technique will promote the development of small-caliber arterial grafts, and furthermore, it may have potential for clinical application.

Entities:  

Mesh:

Year:  2005        PMID: 16094517     DOI: 10.1007/s10047-005-0294-z

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  16 in total

Review 1.  Clinical and biological relevance of vein cuff anastomosis.

Authors:  G Steinthorsson; B Sumpio
Journal:  Acta Chir Belg       Date:  1999-12       Impact factor: 1.090

2.  Fabrication of micropored elastomeric film-covered stents and acute-phase performances.

Authors:  Yasuhide Nakayama; Shogo Nishi; Hatsue Ueda-Ishibashi; Takehisa Matsuda
Journal:  J Biomed Mater Res A       Date:  2003-01-01       Impact factor: 4.396

3.  Coaxial double-tubular compliant arterial graft prosthesis: time-dependent morphogenesis and compliance changes after implantation.

Authors:  Hiromichi Sonoda; Keiichi Takamizawa; Yasuhide Nakayama; Hisataka Yasui; Takehisa Matsuda
Journal:  J Biomed Mater Res A       Date:  2003-05-01       Impact factor: 4.396

4.  In-stent restenosis in small coronary arteries: impact of strut thickness.

Authors:  Carlo Briguori; Cristiano Sarais; Paolo Pagnotta; Francesco Liistro; Matteo Montorfano; Alaide Chieffo; Fabio Sgura; Nicola Corvaja; Remo Albiero; Goran Stankovic; Costantinos Toutoutzas; Erminio Bonizzoni; Carlo Di Mario; Antonio Colombo
Journal:  J Am Coll Cardiol       Date:  2002-08-07       Impact factor: 24.094

5.  Effect of compliance mismatch on vascular graft patency.

Authors:  W M Abbott; J Megerman; J E Hasson; G L'Italien; D F Warnock
Journal:  J Vasc Surg       Date:  1987-02       Impact factor: 4.268

6.  Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial.

Authors:  A Kastrati; J Mehilli; J Dirschinger; F Dotzer; H Schühlen; F J Neumann; M Fleckenstein; C Pfafferott; M Seyfarth; A Schömig
Journal:  Circulation       Date:  2001-06-12       Impact factor: 29.690

7.  Material test system for the evaluation of mechanical properties of biomaterials.

Authors:  K Hayashi; T Nakamura
Journal:  J Biomed Mater Res       Date:  1985-02

8.  Stiffness and elastic behavior of human intracranial and extracranial arteries.

Authors:  K Hayashi; H Handa; S Nagasawa; A Okumura; K Moritake
Journal:  J Biomech       Date:  1980       Impact factor: 2.712

9.  Photocurable surgical tissue adhesive glues composed of photoreactive gelatin and poly(ethylene glycol) diacrylate.

Authors:  Y Nakayama; T Matsuda
Journal:  J Biomed Mater Res       Date:  1999

10.  Comparison of surgical procedures for vascular and airway anastomoses that utilize a modified non-suture external cuff technique for experimental lung transplantation in rats.

Authors:  Teruaki Mizobuchi; Yasuo Sekine; Kazuhiro Yasufuku; Takehiko Fujisawa; David S Wilkes
Journal:  J Heart Lung Transplant       Date:  2004-07       Impact factor: 10.247

View more
  2 in total

1.  Development of biotube vascular grafts incorporating cuffs for easy implantation.

Authors:  Taiji Watanabe; Keiichi Kanda; Hatsue Ishibashi-Ueda; Hitoshi Yaku; Yasuhide Nakayama
Journal:  J Artif Organs       Date:  2007-03-23       Impact factor: 1.731

2.  Implantation study of small-caliber "biotube" vascular grafts in a rat model.

Authors:  Masashi Yamanami; Hatsue Ishibashi-Ueda; Akihide Yamamoto; Hidehiro Iida; Taiji Watanabe; Keiichi Kanda; Hitoshi Yaku; Yasuhide Nakayama
Journal:  J Artif Organs       Date:  2012-11-29       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.