Literature DB >> 1609106

Impact of hard-copy size on observer performance in digital chest radiography.

C M Schaefer1, M Prokop, J W Oestmann, W Wiesmann, B Haubitz, A Meschede, S Reichelt, E Schirg, H S Stender, M Galanski.   

Abstract

To determine the impact of reduced hard-copy size on diagnostic performance of digital radiography, screen-film chest radiographs were compared with isodose digital storage phosphor radiographs in the detection of simulated nodules, fine pulmonary lines, and micronodular opacities superimposed on the chests of 10 healthy volunteers. Digital radiographs were laser-printed in a full-size conventional format and in image lengths of two-thirds, one-half, and five-elevenths of the conventional format. Eighteen thousand observations by eight radiologists were analyzed by use of receiver operating characteristics. The detectability of lines and micronodular opacities decreased with declining image format size. In the detection of micronodular opacities, only the nearly full-size digital images were equivalent to conventional images. In the detection of linear opacities, reduction of image length by one-half or more reduced performance (analysis of variance, P less than .05). Only for the detection of nodules was no major difference found.

Mesh:

Year:  1992        PMID: 1609106     DOI: 10.1148/radiology.184.1.1609106

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Investigation of optimal viewing size for detecting nodular ground-glass opacity on high-resolution computed tomography with cine-mode display.

Authors:  Michihiro Yamaguchi; Yuichi Bessho; Tatsuro Inoue; Yoshiyuki Asai; Tomoshige Matsumoto; Kenya Murase
Journal:  Radiol Phys Technol       Date:  2010-08-19

2.  Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.

Authors:  Claus Koelblinger; Mathias Prokop; Michael Weber; Johannes Sailer; Fabiola Cartes-Zumelzu; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2007-05-10       Impact factor: 5.315

3.  Support line and tube visibility in chest examinations using computed radiography.

Authors:  W Huda; C J Belden; L A Webb; C K Palmer
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

4.  A digital imaging and communications in medicine (DICOM) print service for chest imaging.

Authors:  D M Tucker; C T Suitor; S J Shepard; D F Schomer
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

5.  Does preference influence performance when reading different sizes of cranial computed tomography?

Authors:  Antje C Venjakob; Tim Marnitz; Lavier Gomes; Claudia R Mello-Thoms
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-22

6.  Double-contrast barium enema study with computed radiography: assessment in detection of colorectal polyps.

Authors:  Y Okada; S Kusano; T Endo
Journal:  J Digit Imaging       Date:  1994-08       Impact factor: 4.056

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.