Literature DB >> 20236876

Variable-density parallel imaging with partially localized coil sensitivities.

Tolga Cukur1, Juan M Santos, John M Pauly, Dwight G Nishimura.   

Abstract

Partially parallel imaging with localized sensitivities is a fast parallel image reconstruction method for both Cartesian and non-Cartesian trajectories, but suffers from aliasing artifacts when there are deviations from the assumption of perfect localization. Such reconstructions would normally crop the individual coil images to remove the artifacts prior to combination. However, the sampling densities in variable-density k-space trajectories support different field-of-views for separate regions in k -space. In fact, the higher sampling density of low frequencies can be used to reconstruct a bigger field-of-view without introducing aliasing artifacts and the resulting image signal-to-noise ratio (SNR) can be improved. A novel, fast variable-density parallel imaging method is presented, which reconstructs different field-of-views from separate frequencies according to the local sampling density in k-space. Aliasing-suppressed images can be produced with high SNR-efficiency without the need for accurate estimation of coil sensitivities and complex or iterative computations.

Entities:  

Mesh:

Year:  2010        PMID: 20236876      PMCID: PMC3155390          DOI: 10.1109/TMI.2010.2042805

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  34 in total

1.  Resampling of data between arbitrary grids using convolution interpolation.

Authors:  V Rasche; R Proksa; R Sinkus; P Börnert; H Eggers
Journal:  IEEE Trans Med Imaging       Date:  1999-05       Impact factor: 10.048

2.  Self-calibrating parallel imaging with automatic coil sensitivity extraction.

Authors:  Charles A McKenzie; Ernest N Yeh; Michael A Ohliger; Mark D Price; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  VD-AUTO-SMASH imaging.

Authors:  R M Heidemann; M A Griswold; A Haase; P M Jakob
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

4.  Broadband multicoil imaging using multiple demodulation hardware: a feasibility study.

Authors:  Jin Hyung Lee; Greig C Scott; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

5.  Single breath-hold whole-heart MRA using variable-density spirals at 3T.

Authors:  Juan M Santos; Charles H Cunningham; Michael Lustig; Brian A Hargreaves; Bob S Hu; Dwight G Nishimura; John M Pauly
Journal:  Magn Reson Med       Date:  2006-02       Impact factor: 4.668

6.  Flexible real-time magnetic resonance imaging framework.

Authors:  Juan M Santos; Graham A Wright; John M Pauly
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

7.  Fast method for 1D non-cartesian parallel imaging using GRAPPA.

Authors:  Robin M Heidemann; Mark A Griswold; Nicole Seiberlich; Mathias Nittka; Stephan A R Kannengiesser; Berthold Kiefer; Peter M Jakob
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

8.  Multiple-profile homogeneous image combination: application to phase-cycled SSFP and multicoil imaging.

Authors:  Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

9.  Simultaneous spatial and spectral selective excitation.

Authors:  C H Meyer; J M Pauly; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1990-08       Impact factor: 4.668

10.  AUTO-SMASH: a self-calibrating technique for SMASH imaging. SiMultaneous Acquisition of Spatial Harmonics.

Authors:  P M Jakob; M A Griswold; R R Edelman; D K Sodickson
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

View more
  2 in total

1.  Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging.

Authors:  Holden H Wu; Paul T Gurney; Bob S Hu; Dwight G Nishimura; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

2.  Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging.

Authors:  Yong Pang; Zhentian Xie; Ye Li; Duan Xu; Daniel Vigneron; Xiaoliang Zhang
Journal:  Materials (Basel)       Date:  2011-07-28       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.