Literature DB >> 33728700

Aliasing artifact reduction in spiral real-time MRI.

Ye Tian1, Yongwan Lim1, Ziwei Zhao1, Dani Byrd2, Shrikanth Narayanan1,2, Krishna S Nayak1.   

Abstract

PURPOSE: To mitigate a common artifact in spiral real-time MRI, caused by aliasing of signal outside the desired FOV. This artifact frequently occurs in midsagittal speech real-time MRI.
METHODS: Simulations were performed to determine the likely origin of the artifact. Two methods to mitigate the artifact are proposed. The first approach, denoted as "large FOV" (LF), keeps an FOV that is large enough to include the artifact signal source during reconstruction. The second approach, denoted as "estimation-subtraction" (ES), estimates the artifact signal source before subtracting a synthetic signal representing that source in multicoil k-space raw data. Twenty-five midsagittal speech-production real-time MRI data sets were used to evaluate both of the proposed methods. Reconstructions without and with corrections were evaluated by two expert readers using a 5-level Likert scale assessing artifact severity. Reconstruction time was also compared.
RESULTS: The origin of the artifact was found to be a combination of gradient nonlinearity and imperfect anti-aliasing in spiral sampling. The LF and ES methods were both able to substantially reduce the artifact, with an averaged qualitative score improvement of 1.25 and 1.35 Likert levels for LF correction and ES correction, respectively. Average reconstruction time without correction, with LF correction, and with ES correction were 160.69 ± 1.56, 526.43 ± 5.17, and 171.47 ± 1.71 ms/frame.
CONCLUSION: Both proposed methods were able to reduce the spiral aliasing artifacts, with the ES-reduction method being more effective and more time efficient.
© 2021 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  gradient nonlinearity; low-pass filter; real-time MRI; speech production; spiral trajectory

Mesh:

Year:  2021        PMID: 33728700      PMCID: PMC8076071          DOI: 10.1002/mrm.28746

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   3.737


  37 in total

1.  Partial-FOV reconstruction in dynamic spiral imaging.

Authors:  H Sedarat; A B Kerr; J M Pauly; D G Nishimura
Journal:  Magn Reson Med       Date:  2000-03       Impact factor: 4.668

2.  Adaptive reconstruction of phased array MR imagery.

Authors:  D O Walsh; A F Gmitro; M W Marcellin
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

3.  Electromagnetic midsagittal articulometer systems for transducing speech articulatory movements.

Authors:  J S Perkell; M H Cohen; M A Svirsky; M L Matthies; I Garabieta; M T Jackson
Journal:  J Acoust Soc Am       Date:  1992-12       Impact factor: 1.840

4.  Streaking artifact reduction for quantitative susceptibility mapping of sources with large dynamic range.

Authors:  Hongjiang Wei; Russell Dibb; Yan Zhou; Yawen Sun; Jianrong Xu; Nian Wang; Chunlei Liu
Journal:  NMR Biomed       Date:  2015-08-27       Impact factor: 4.044

5.  Temporally constrained reconstruction of dynamic cardiac perfusion MRI.

Authors:  Ganesh Adluru; Suyash P Awate; Tolga Tasdizen; Ross T Whitaker; Edward V R Dibella
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

6.  Improved real-time tagged MRI using REALTAG.

Authors:  Weiyi Chen; Nam Gyun Lee; Dani Byrd; Shrikanth Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-12-24       Impact factor: 4.668

7.  Automatic coil selection for streak artifact reduction in radial MRI.

Authors:  Yiqun Xue; Jiangsheng Yu; Hyun Seon Kang; Sarah Englander; Mark A Rosen; Hee Kwon Song
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

8.  Cross-sectional tongue shape during the production of vowels.

Authors:  M Stone; T H Shawker; T L Talbot; A H Rich
Journal:  J Acoust Soc Am       Date:  1988-04       Impact factor: 1.840

9.  Dynamic off-resonance correction for spiral real-time MRI of speech.

Authors:  Yongwan Lim; Sajan Goud Lingala; Shrikanth S Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2018-07-29       Impact factor: 4.668

10.  A method for estimating and removing streaking artifacts in quantitative susceptibility mapping.

Authors:  Wei Li; Nian Wang; Fang Yu; Hui Han; Wei Cao; Rebecca Romero; Bundhit Tantiwongkosi; Timothy Q Duong; Chunlei Liu
Journal:  Neuroimage       Date:  2014-12-20       Impact factor: 6.556

View more
  1 in total

1.  A multispeaker dataset of raw and reconstructed speech production real-time MRI video and 3D volumetric images.

Authors:  Yongwan Lim; Asterios Toutios; Yannick Bliesener; Ye Tian; Sajan Goud Lingala; Colin Vaz; Tanner Sorensen; Miran Oh; Sarah Harper; Weiyi Chen; Yoonjeong Lee; Johannes Töger; Mairym Lloréns Monteserin; Caitlin Smith; Bianca Godinez; Louis Goldstein; Dani Byrd; Krishna S Nayak; Shrikanth S Narayanan
Journal:  Sci Data       Date:  2021-07-20       Impact factor: 6.444

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.