Literature DB >> 16086181

Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices.

Ray Valencia1, Timm Denecke, Lukas Lehmkuhl, Frank Fischbach, Roland Felix, Friedrich Knollmann.   

Abstract

The purpose of this study was to investigate the diagnostic accuracy of non-overlapping 10-mm axial and coronal maximum intensity projections (MIP) in comparison with standard axial 1-mm and 5-mm slices in the detection of pulmonary nodules. Sixty patients with suspected nodules who underwent multislice spiral CT of the chest were evaluated. Axial 1-mm and 5-mm slices as well as non-overlapping 10-mm axial/coronal MIPs were interpreted independently by three blinded radiologists. After initial review, a retrospective consensus session was performed for agreement on final nodule counts using the axial 1-mm slices as gold standard. Small nodules of less than 5 mm in size were most accurately detected by the axial MIPs. Receiver operating characteristic (ROC) analysis of these small nodules showed that 5-mm slices were not capable of a statistically significant differentiation of nodules from other focal lesions in two observers (p=0.034 and p=0.012, respectively) whereas 1-mm slices and coronal/axial MIPs did allow a statistically significant differentiation in all observers (p<0.001). Nodules larger than 5 mm were equally well depicted with all modalities. Non-overlapping 10-mm axial MIPs improve the accuracy in the detection of small pulmonary nodules.

Entities:  

Mesh:

Year:  2005        PMID: 16086181     DOI: 10.1007/s00330-005-2871-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  26 in total

Review 1.  Data explosion: the challenge of multidetector-row CT.

Authors:  G D Rubin
Journal:  Eur J Radiol       Date:  2000-11       Impact factor: 3.528

2.  Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists' detection performance.

Authors:  Kazuo Awai; Kohei Murao; Akio Ozawa; Masanori Komi; Haruo Hayakawa; Shinichi Hori; Yasumasa Nishimura
Journal:  Radiology       Date:  2004-02       Impact factor: 11.105

3.  Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists.

Authors:  Katharina Marten; Tobias Seyfarth; Florian Auer; Edzard Wiener; Andreas Grillhösl; Silvia Obenauer; Ernst J Rummeny; Christoph Engelke
Journal:  Eur Radiol       Date:  2004-07-03       Impact factor: 5.315

4.  Glossary of terms for CT of the lungs: recommendations of the Nomenclature Committee of the Fleischner Society.

Authors:  J H Austin; N L Müller; P J Friedman; D M Hansell; D P Naidich; M Remy-Jardin; W R Webb; E A Zerhouni
Journal:  Radiology       Date:  1996-08       Impact factor: 11.105

5.  Early Lung Cancer Action Project: overall design and findings from baseline screening.

Authors:  C I Henschke; D I McCauley; D F Yankelevitz; D P Naidich; G McGuinness; O S Miettinen; D M Libby; M W Pasmantier; J Koizumi; N K Altorki; J P Smith
Journal:  Lancet       Date:  1999-07-10       Impact factor: 79.321

6.  Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers.

Authors:  Stefan Diederich; Dag Wormanns; Michael Semik; Michael Thomas; Horst Lenzen; Nikolaus Roos; Walter Heindel
Journal:  Radiology       Date:  2002-03       Impact factor: 11.105

7.  [Multidetector-row CT of the lungs: Multiplanar reconstructions and maximum intensity projections for the detection of pulmonary nodules].

Authors:  R Eibel; T R Türk; C Kulinna; K Herrmann; M F Reiser
Journal:  Rofo       Date:  2001-09

Review 8.  Characterization of small pulmonary nodules by CT.

Authors:  Dag Wormanns; Stefan Diederich
Journal:  Eur Radiol       Date:  2004-05-18       Impact factor: 5.315

9.  Diffuse infiltrative lung disease: clinical value of sliding-thin-slab maximum intensity projection CT scans in the detection of mild micronodular patterns.

Authors:  M Remy-Jardin; J Remy; D Artaud; F Deschildre; A Duhamel
Journal:  Radiology       Date:  1996-08       Impact factor: 11.105

10.  Spiral CT of the chest: comparison of cine and film-based viewing.

Authors:  S E Seltzer; P F Judy; D F Adams; F L Jacobson; P Stark; R Kikinis; R G Swensson; S Hooton; B Head; U Feldman
Journal:  Radiology       Date:  1995-10       Impact factor: 11.105

View more
  18 in total

1.  Performance of ultralow-dose CT with iterative reconstruction in lung cancer screening: limiting radiation exposure to the equivalent of conventional chest X-ray imaging.

Authors:  Adrian Huber; Julia Landau; Lukas Ebner; Yanik Bütikofer; Lars Leidolt; Barbara Brela; Michelle May; Johannes Heverhagen; Andreas Christe
Journal:  Eur Radiol       Date:  2016-01-26       Impact factor: 5.315

2.  Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners.

Authors:  Marco Das; Julia Ley-Zaporozhan; H A Gietema; Andre Czech; Georg Mühlenbruch; Andreas H Mahnken; Markus Katoh; Annemarie Bakai; Marcos Salganicoff; Stefan Diederich; Mathias Prokop; Hans-Ulrich Kauczor; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

3.  Pulmonary nodule detection on MDCT images: evaluation of diagnostic performance using thin axial images, maximum intensity projections, and computer-assisted detection.

Authors:  A Jankowski; T Martinelli; J F Timsit; C Brambilla; F Thony; M Coulomb; G Ferretti
Journal:  Eur Radiol       Date:  2007-09-01       Impact factor: 5.315

4.  Multi slice computed tomography in the study of pulmonary metastases.

Authors:  G Angelelli; V Grimaldi; F Spinelli; A Scardapane; A Sardaro
Journal:  Radiol Med       Date:  2008-09-08       Impact factor: 3.469

Review 5.  CT protocols in interstitial lung diseases--a survey among members of the European Society of Thoracic Imaging and a review of the literature.

Authors:  Helmut Prosch; Cornelia M Schaefer-Prokop; Edith Eisenhuber; Daniela Kienzl; Christian J Herold
Journal:  Eur Radiol       Date:  2012-12-13       Impact factor: 5.315

Review 6.  Lung cancer screening: nodule identification and characterization.

Authors:  Ioannis Vlahos; Konstantinos Stefanidis; Sarah Sheard; Arjun Nair; Charles Sayer; Joanne Moser
Journal:  Transl Lung Cancer Res       Date:  2018-06

7.  Significance of pulmonary nodules in patients with colorectal cancer.

Authors:  Fabio Pomerri; Salvatore Pucciarelli; Isacco Maretto; Ernesta Perrone; Giovanna Pintacuda; Sara Lonardi; Donato Nitti; Pier Carlo Muzzio
Journal:  Eur Radiol       Date:  2012-04-01       Impact factor: 5.315

8.  Tumor staging using whole-body high-resolution 16-channel PET-CT: does additional low-dose chest CT in inspiration improve the detection of solitary pulmonary nodules?

Authors:  K U Juergens; M Weckesser; L Stegger; C Franzius; M Beetz; O Schober; W Heindel; D Wormanns
Journal:  Eur Radiol       Date:  2006-02-01       Impact factor: 5.315

Review 9.  Low-Dose CT Screening for Lung Cancer: Evidence from 2 Decades of Study.

Authors:  David S Gierada; William C Black; Caroline Chiles; Paul F Pinsky; David F Yankelevitz
Journal:  Radiol Imaging Cancer       Date:  2020-03-27

10.  Detection of pulmonary nodules at paediatric CT: maximum intensity projections and axial source images are complementary.

Authors:  Fleur Kilburn-Toppin; Owen J Arthurs; Angela D Tasker; Patricia A K Set
Journal:  Pediatr Radiol       Date:  2013-01-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.