Literature DB >> 7568857

Spiral CT of the chest: comparison of cine and film-based viewing.

S E Seltzer1, P F Judy, D F Adams, F L Jacobson, P Stark, R Kikinis, R G Swensson, S Hooton, B Head, U Feldman.   

Abstract

PURPOSE: To determine radiologists' ability to find lung nodules on spiral computed tomographic (CT) scans of the chest with both rapid sequential (cine) and conventional film-based viewing.
MATERIALS AND METHODS: Eight radiologists searched for lung nodules on spiral CT images (10-mm collimation, 10 mm/sec table speed) presented in two formats. Cine viewing was performed at a computer work-station; sections were viewed in 2-mm increments at frame rates up to 10 frames per second. Film-based viewing of images from a laser printer was performed with a lightbox; sections were viewed at 4-mm increments. Eight 3-5-mm-diameter simulated nodules were superimposed on each of five normal CT scans.
RESULTS: Radiologists found a higher fraction of nodules with the cine presentation than with film (mean, 0.69 +/- 0.02 [standard error] versus 0.58 +/- 0.03, respectively [P = .006]). Diameter thresholds for nodule detection (50% correctly localized) were 3.3 and 3.5 mm, respectively.
CONCLUSION: Cine viewing of spiral CT images of the chest improved radiologists' ability to detect nodules.

Entities:  

Mesh:

Year:  1995        PMID: 7568857     DOI: 10.1148/radiology.197.1.7568857

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  21 in total

1.  Investigation of optimal viewing size for detecting nodular ground-glass opacity on high-resolution computed tomography with cine-mode display.

Authors:  Michihiro Yamaguchi; Yuichi Bessho; Tatsuro Inoue; Yoshiyuki Asai; Tomoshige Matsumoto; Kenya Murase
Journal:  Radiol Phys Technol       Date:  2010-08-19

2.  Computational assessment of visual search strategies in volumetric medical images.

Authors:  Gezheng Wen; Avigael Aizenman; Trafton Drew; Jeremy M Wolfe; Tamara Miner Haygood; Mia K Markey
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-06

3.  Image toggling saves time in mammography.

Authors:  Trafton Drew; Avi M Aizenman; Matthew B Thompson; Mark D Kovacs; Michael Trambert; Murray A Reicher; Jeremy M Wolfe
Journal:  J Med Imaging (Bellingham)       Date:  2015-10-12

4.  Solitary pulmonary nodule: detection and management.

Authors:  S Diederich; M Das
Journal:  Cancer Imaging       Date:  2006-10-31       Impact factor: 3.909

5.  Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT.

Authors:  Dag Wormanns; Karl Ludwig; Florian Beyer; Walter Heindel; Stefan Diederich
Journal:  Eur Radiol       Date:  2004-11-04       Impact factor: 5.315

6.  Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices.

Authors:  Ray Valencia; Timm Denecke; Lukas Lehmkuhl; Frank Fischbach; Roland Felix; Friedrich Knollmann
Journal:  Eur Radiol       Date:  2005-08-16       Impact factor: 5.315

7.  Postprocessing technique with MDCT data improves the accuracy of the detection of lung nodules.

Authors:  Kazuhide Yoneda; Junji Ueno; Sadamitsu Nishihara; Tetsuya Tsujikawa; Naomi Morita; Hideki Otsuka; Kaori Furutani; Hiromu Nishitani; Kazuya Kondo; Yasuhiko Nishioka
Journal:  Radiat Med       Date:  2007-12-25

8.  Pulmonary nodule detection on MDCT images: evaluation of diagnostic performance using thin axial images, maximum intensity projections, and computer-assisted detection.

Authors:  A Jankowski; T Martinelli; J F Timsit; C Brambilla; F Thony; M Coulomb; G Ferretti
Journal:  Eur Radiol       Date:  2007-09-01       Impact factor: 5.315

9.  Processes involved in reading imaging studies: workflow analysis and implications for workstation development.

Authors:  S B Gay; A H Sobel; L Q Young; S J Dwyer
Journal:  J Digit Imaging       Date:  1997-02       Impact factor: 4.056

Review 10.  Lung metastases.

Authors:  C J Herold; A A Bankier; D Fleischmann
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.