Literature DB >> 16078924

The quality of fresh-frozen plasma produced from whole blood stored at 4 degrees C overnight.

Rebecca Cardigan1, Andrew S Lawrie, Ian J Mackie, Lorna M Williamson.   

Abstract

BACKGROUND: The aim of this study was to assess whether the quality of FFP produced from whole blood stored at 4 degrees C overnight is adequate for its intended purpose. STUDY DESIGN AND METHODS: Fresh-frozen plasma (FFP) separated from whole blood (n = 60) leukodepleted (LD) after storage at 4 degrees C overnight (18-24 hr from donation, Day 1 FFP) was compared with that LD within 8 hours of donation (Day 0 FFP, the current standard method).
RESULTS: In more than 95 percent of Day 1 FFP units, levels of factor (F) II, FV, FVII, FVIII, F IX, FX, FXI, and FXII were greater than 0.50 U per mL except for von Willebrand factor (VWF) antigen and FVIII, where 92 and 87 percent of units, respectively, contained greater than 0.50 IU per mL. Compared with historical data on FFP stored for 8 hours, fibrinogen, FV, FVIII, and FXI were reduced by 12, 15, 23, and 7 percent, respectively, but other factors were not significantly reduced. Levels of VWF-cleaving protease activity were not different between FFP prepared from paired units of blood (n = 3) held for 8 or 24 hours, but were below the reference range in an additional 2 of 6 units held for 24 hours. The activities of protein S, protein C, antithrombin III, and alpha(2)-antiplasmin were reduced by less than 10 percent in Day 1 FFP (n = 20), but with final levels above the lower limit of the normal range in greater than 95 percent of units. Activated FXII antigen was not significantly raised in plasma stored for 18 to 24 hours, but levels of prothrombin fragment 1 + 2 were slightly increased (0.88 ng/mL, 18-24 hr; 0.65 ng/mL, < 8 hr).
CONCLUSION: These data suggest that there is good retention of relevant coagulation factor activity in plasma produced from whole blood stored at 4 degrees C for 18 to 24 hours and that this would be an acceptable product for most patients requiring FFP.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16078924     DOI: 10.1111/j.1537-2995.2005.00219.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  13 in total

1.  Levels of factor VIII and factor IX in fresh-frozen plasma produced from whole blood stored at 4 °C overnight in Turkey.

Authors:  Neval Agus; Nisel Yilmaz; Ayfer Colak; Fatma Liv
Journal:  Blood Transfus       Date:  2011-11-16       Impact factor: 3.443

2.  Thawed solvent/detergent-treated plasma: too precious to be wasted after 6 hours?

Authors:  Mareike Kristina Keller; Axel Pruss; Michael Sander; Claudia Spies; Helge Schoenfeld; Michael Schuster; Kristian Meinck; Klaus-Dieter Wernecke; Christian Von Heymann
Journal:  Blood Transfus       Date:  2012-03-28       Impact factor: 3.443

3.  A comparative study of the effects of temperature, time and factor VIII assay type on factor VIII activity in cryoprecipitate in Iran.

Authors:  Azadeh Omidkhoda; Mohammad Reza Tabatabaei; Kamran Atarodi; Kamran Karimi; Abbas Rahimi Froushani; Ali Akbar Pourfathollah
Journal:  Blood Transfus       Date:  2011-07-18       Impact factor: 3.443

4.  A study of the quantity of some stable and labile coagulation factors in fresh-frozen plasma produced from whole blood stored for 24 hours in Iran.

Authors:  Hossin Timori Naghadeh; Mehryar Habibi Roudkenar
Journal:  Blood Transfus       Date:  2009-01       Impact factor: 3.443

5.  Comparison of quality of red blood cells made from whole blood (after 8 and 24 hours holding time at 2-6 °C and 20-24 °C) in Iran.

Authors:  Azadeh Omidkhoda; Sedigheh Amini Kafi Abad
Journal:  Blood Transfus       Date:  2013-11-15       Impact factor: 3.443

6.  Pathogen Reduction Technology Treatment of Platelets, Plasma and Whole Blood Using Riboflavin and UV Light.

Authors:  Susanne Marschner; Raymond Goodrich
Journal:  Transfus Med Hemother       Date:  2011-01-31       Impact factor: 3.747

Review 7.  10 Years of Experience with the First Thawed Plasma Bank in Germany.

Authors:  Kathleen Selleng; Andreas Greinacher
Journal:  Transfus Med Hemother       Date:  2021-10-08       Impact factor: 3.747

8.  Evaluation of Coagulation Factors Activity in Different Types of Plasma Preparations.

Authors:  Ola Abdel Halim Afifi; Eman M Nagiub Abdelsalam; Amina Abd El Aal Mohammed Makhlouf; Maha Atwa Mohamed Ibrahim
Journal:  Indian J Hematol Blood Transfus       Date:  2018-11-12       Impact factor: 0.900

9.  The how's and why's of evidence based plasma therapy.

Authors:  Mark H Yazer
Journal:  Korean J Hematol       Date:  2010-09-30

10.  A comparison study of the blood component quality of whole blood held overnight at 4°c or room temperature.

Authors:  Shichun Wang; Tiantian Wang; Yahan Fan; Shan Huang; Zhongmei Yi; Ruiqing Li; Shuming Zhao
Journal:  J Blood Transfus       Date:  2013-09-05
View more