Literature DB >> 16054665

Acousto-optic, point receiver hydrophone probe for operation up to 100 MHz.

P A Lewin1, C Mu, S Umchid, A Daryoush, M El-Sherif.   

Abstract

This work describes the results of initial evaluation of a wideband acousto-optic hydrophone probe designed to operate as point receiver in the frequency range up to 100 MHz. The hydrophone was implemented as a tapered fiber optic (FO) probe sensor with a tip diameter of approximately 7 microm. Such small physical dimensions of the sensor eliminate the need for spatial averaging corrections so that true pressure-time (p-t) waveforms can be faithfully recorded. The theoretical considerations that predicted the FO probe sensitivity to be equal to 4.3 mV/MPa are presented along with a brief description of the manufacturing process. The calibration results that verified the theoretically predicted sensitivity are also presented along with a brief description of the improvements being currently implemented to increase this sensitivity level by approximately 20 dB. The results of preliminary measurements indicate that the fiber optic probes will exhibit a uniform frequency response and a zero phase shift in the frequency range considered. These features might be very useful in rapid complex calibration i.e. determining both magnitude and phase response of other hydrophones by the substitution method. Also, because of their robust design and linearity, these fiber optic hydrophones could also meet the challenges posed by high intensity focused ultrasound (HIFU) and other therapeutic applications. Overall, the outcome of this work shows that when fully developed, the FO probes will be well suited for high frequency measurements of ultrasound fields and will be able to complement the data collected by the current finite aperture piezoelectric PVDF hydrophones.

Entities:  

Mesh:

Year:  2005        PMID: 16054665     DOI: 10.1016/j.ultras.2005.05.003

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  10 in total

1.  A comparison of light spot hydrophone and fiber optic probe hydrophone for lithotripter field characterization.

Authors:  N Smith; G N Sankin; W N Simmons; R Nanke; J Fehre; P Zhong
Journal:  Rev Sci Instrum       Date:  2012-01       Impact factor: 1.523

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

4.  Nonlinear Acoustics in Ultrasound Metrology and other Selected Applications.

Authors:  Peter A Lewin
Journal:  Phys Procedia       Date:  2010-01-01

5.  Correction for Spatial Averaging Artifacts in Hydrophone Measurements of High-Intensity Therapeutic Ultrasound: An Inverse Filter Approach.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-24       Impact factor: 2.725

6.  Spatiotemporal Deconvolution of Hydrophone Response for Linear and Nonlinear Beams-Part I: Theory, Spatial-Averaging Correction Formulas, and Criteria for Sensitive Element Size.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

7.  Directivity and Frequency-Dependent Effective Sensitive Element Size of a Reflectance-Based Fiber-Optic Hydrophone: Predictions From Theoretical Models Compared With Measurements.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

8.  Pressure Pulse Distortion by Needle and Fiber-Optic Hydrophones due to Nonuniform Sensitivity.

Authors:  Keith A Wear; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-02       Impact factor: 2.725

9.  Characterization of a 40-MHz focused transducer with a fiber grating laser hydrophone.

Authors:  Sien-Ting Lau; Li-Yang Shao; Helen Lai-Wa Chan; Hwa-Yaw Tam; Chang-Hong Hu; Hyung-Ham Kim; Ruibin Liu; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-12       Impact factor: 2.725

10.  Development of calibration techniques for ultrasonic hydrophone probes in the frequency range from 1 to 100 MHz.

Authors:  S Umchid; R Gopinath; K Srinivasan; P A Lewin; A S Daryoush; L Bansal; M El-Sherif
Journal:  Ultrasonics       Date:  2008-10-21       Impact factor: 2.890