Literature DB >> 16053844

Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system.

M Heiland1, D Schulze, F Blake, R Schmelzle.   

Abstract

After preclinical studies and evaluation of radiation exposures, intraoperative three-dimensional (3D) C-arm based imaging is now available for the facial skeleton. Fourteen patients admitted for surgical treatment of zygomaticomaxillary complex (ZMC) fractures were included in the study. Preoperative diagnostics and surgical treatment were performed as usual. Intraoperatively, after open reduction, a cone-beam computed tomography (CBCT) dataset was generated using the SIREMOBIL Iso-C3D (Siemens Medical Solutions, Erlangen, Germany). After DICOM-import in eFilm Workstation axial, coronal and sagittal reconstructions were evaluated by five examiners with the help of six defined criteria. In our study, secondary reconstructions were available after 6 min, excluding the time needed for the evaluation of the images. Especially the positioning of the isocentre of the SIREMOBIL Iso-C3D proved to be uncomplicated. Because of the size of the datasets, assessment of the symmetry of the malar projection proved difficult. Best scoring results were found regarding the visualization of the fragment position, bony anchorage of the screws and the fitting of the plates. Remarkable was the low level of metal artefacts in primary and secondary reconstructions. In conclusion, our results demonstrate intraoperative CBCT using the SIREMOBIL Iso-C3D suitable for assessment of postoperative results following ZMC reduction.

Entities:  

Mesh:

Year:  2005        PMID: 16053844     DOI: 10.1016/j.ijom.2004.09.010

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  14 in total

Review 1.  Use of cone beam computed tomography in otolaryngologic treatments.

Authors:  Hamdi Cakli; Cemal Cingi; Yazgi Ay; Fatih Oghan; Torun Ozer; Ercan Kaya
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-09-27       Impact factor: 2.503

2.  Improved surgical procedure using intraoperative navigation for the implantation of the SPG microstimulator in patients with chronic cluster headache.

Authors:  Carsten Kohlmeier; Peter Behrens; Andreas Böger; Brinda Ramachandran; Anthony Caparso; Dirk Schulze; Philipp Stude; Max Heiland; Alexandre T Assaf
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-12       Impact factor: 2.924

3.  Intraoral osteotomies using piezosurgery for distraction in an infant with Pierre-Robin sequence.

Authors:  Max Heiland; Marco Blessmann; Philipp Pohlenz; Lei Li; Rainer Schmelzle; Felix Blake
Journal:  Clin Oral Investig       Date:  2007-01-03       Impact factor: 3.573

4.  Impact of prone, supine and oblique patient positioning on CBCT image quality, contrast-to-noise ratio and figure of merit value in the maxillofacial region.

Authors:  Juha Koivisto; Maureen van Eijnatten; Jorma Järnstedt; Kirsi Holli-Helenius; Prasun Dastidar; Jan Wolff
Journal:  Dentomaxillofac Radiol       Date:  2017-04-07       Impact factor: 2.419

5.  Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans.

Authors:  Simon Veldhoen; Maximilian Schöllchen; H Hanken; C Precht; F O Henes; G Schön; H D Nagel; U Schumacher; M Heiland; G Adam; M Regier
Journal:  Eur Radiol       Date:  2016-05-11       Impact factor: 5.315

Review 6.  A Diagnosis of Maxillary Sinus Fracture with Cone-Beam CT: Case Report and Literature Review.

Authors:  Selmi Yardimci Yilmaz; Melda Misirlioglu; Mehmet Zahit Adisen
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-03-04

7.  Current Management of Zygomaticomaxillary Complex Fractures: A Multidisciplinary Survey and Literature Review.

Authors:  Scott J Farber; Dennis C Nguyen; Gary B Skolnick; Albert S Woo; Kamlesh B Patel
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2016-09-16

8.  "Is Cone Beam Computed Tomography (CBCT) a Potential Imaging Tool in ENT Practice?: A Cross-Sectional Survey Among ENT Surgeons in the State of Odisha, India.

Authors:  S Lata; S K Mohanty; S Vinay; Abhaya Chandra Das; Sanjib Das; Priyadarshini Choudhury
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2017-08-05

9.  Depth-Based, Motion-Stabilized Colorization of Microscope-Integrated Optical Coherence Tomography Volumes for Microscope-Independent Microsurgery.

Authors:  Isaac D Bleicher; Moseph Jackson-Atogi; Christian Viehland; Hesham Gabr; Joseph A Izatt; Cynthia A Toth
Journal:  Transl Vis Sci Technol       Date:  2018-11-01       Impact factor: 3.283

10.  Does Intraoperative Computed Tomography Improve the Outcome in Zygomatico-Orbital Complex Fracture Reduction?

Authors:  Preeti Sharma; Vidya Rattan; Sachin Rai; Rajesh Chhabbra
Journal:  J Maxillofac Oral Surg       Date:  2020-07-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.