Literature DB >> 16039706

Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures.

M Rosentritt1, M Behr, R Gebhard, G Handel.   

Abstract

OBJECTIVES: This in vitro study tested the influence of diverse stress simulation parameters on the fracture strength of all-ceramic three-unit fixed partial dentures (FPDs).
METHODS: All-ceramic FPDs made of Empress 2 (Ivoclar-Vivadent, FL) were exposed to thermal cycling and mechanical loading (TCML) with varying loading parameters such as chewing force (amount, frequency), thermal loading, lateral jaw motion, abutment material, artificial periodontium or antagonistic denture. To investigate the influence of the abutment material, human teeth, polymer abutments and alloy abutments were used. Two different TCML devices with pneumatic or weight loading were compared. FPDs without aging were used as a control. RESULTS AND SIGNIFICANCE: Combined thermal and mechanical loading significantly reduced the FPD fracture resistance from 1832N to 410N. Duplication of chewing frequency, phase load increase or additional lateral movement did not effect the results. Increasing chewing force, artificial periodontium, and antagonist or abutment material reduced the fracture resistance of the tested FPDs. Different devices with weight or pneumatic loading had no significant influence on the loading capacity of the FPDs. Artificial aging should be performed combining thermal cycling with mechanical loading. Simulation of the artificial periodontium, human antagonists and abutments should be included to achieve a significant aging.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16039706     DOI: 10.1016/j.dental.2005.04.024

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  38 in total

1.  Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures.

Authors:  Martin Rosentritt; Carola Kolbeck; Gerhard Handel; Sibylle Schneider-Feyrer; Michael Behr
Journal:  Clin Oral Investig       Date:  2010-10-05       Impact factor: 3.573

2.  Influence of type of luting cement used with all-ceramic crowns on load capability of post-restored endodontically treated maxillary central incisors.

Authors:  Anja Preuss; Martin Rosentritt; Roland Frankenberger; Florian Beuer; Michael Naumann
Journal:  Clin Oral Investig       Date:  2007-11-27       Impact factor: 3.573

3.  The impact of cement mixing and storage errors on the risk of failure of glass-ceramic crowns.

Authors:  H Loher; M Behr; U Hintereder; M Rosentritt; G Handel
Journal:  Clin Oral Investig       Date:  2008-08-22       Impact factor: 3.573

4.  Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns.

Authors:  Verena Preis; Thomas Dowerk; Michael Behr; Carola Kolbeck; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2013-07-12       Impact factor: 3.573

5.  In vitro evaluation of artificial ageing on surface properties and early Candida albicans adhesion to prosthetic resins.

Authors:  Sebastian Hahnel; Martin Rosentritt; Gerhard Handel; Ralf Bürgers
Journal:  J Mater Sci Mater Med       Date:  2008-08-30       Impact factor: 3.896

6.  Analysis of marginal adaptation and sealing to enamel and dentin of four self-adhesive resin cements.

Authors:  Carina Maria Aschenbrenner; Reinhold Lang; Gerhard Handel; Michael Behr
Journal:  Clin Oral Investig       Date:  2011-02-16       Impact factor: 3.573

7.  Two-body wear of dental porcelain and substructure oxide ceramics.

Authors:  Martin Rosentritt; Verena Preis; Michael Behr; Sebastian Hahnel; Gerhard Handel; Carola Kolbeck
Journal:  Clin Oral Investig       Date:  2011-07-08       Impact factor: 3.573

8.  Load-bearing capacity of artificially aged zirconia fixed dental prostheses with heterogeneous abutment supports.

Authors:  Katia Sarafidou; Meike Stiesch; Marc Philipp Dittmer; Daniela Jörn; Lothar Borchers; Philipp Kohorst
Journal:  Clin Oral Investig       Date:  2011-05-24       Impact factor: 3.573

9.  Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology.

Authors:  Moritz Zimmermann; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2019-07-08       Impact factor: 3.573

10.  Polishing effects and wear performance of chairside CAD/CAM materials.

Authors:  Mike Matzinger; Sebastian Hahnel; Verena Preis; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2018-05-16       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.