Literature DB >> 16037868

Hemodynamic performance and incidence of patient-prosthesis mismatch of the complete supraannular perimount magna bioprosthesis in the aortic position.

F Botzenhardt1, W B Eichinger, R Guenzinger, S Bleiziffer, I Wagner, R Bauernschmitt, R Lange.   

Abstract

BACKGROUND: Complete supraannular placement and smaller stent design allow the implantation of a Perimount Magna bioprosthesis with a larger inner diameter than that of a standard Perimount. This study compares the hemodynamic performance and the incidence of patient-prosthesis mismatch (PPM) of both prostheses.
METHODS: 128 patients underwent aortic valve replacement, receiving either a Magna (n = 57) or a standard (n = 71) prosthesis. Inner aortic annulus diameter was measured intraoperatively by a hegar dilator to match echocardiographically obtained results to the annulus diameter instead of matching them to labelled valve size.
RESULTS: The Magna was significantly superior with respect to mean pressure gradient and effective orifice area in patients with an annulus diameter of 22-23 mm. In patients with an annulus diameter < 22 mm or > 23 mm, there was a non-significant trend towards superior hemodynamics in the Magna group. Severe PPM (effective orifice area index < or = 0.65 cm (2)/m (2)) was present in 11.1% (Magna) vs. 42.1% (Standard) of patients with an annulus diameter < 22 mm; in 0% (Magna) vs. 13.8% (Standard) with an annulus diameter of 22-23 mm; no PPM was seen in patients with annulus diameter > 23 mm in both groups.
CONCLUSIONS: The Perimount Magna had a significantly reduced incidence of patient-prosthesis mismatch and superior hemodynamics compared to the standard Perimount.

Entities:  

Mesh:

Year:  2005        PMID: 16037868     DOI: 10.1055/s-2005-837678

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827


  15 in total

Review 1.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

2.  Primary echocardiographic results of the Carpentier-Edwards Perimount Magna.

Authors:  Hiroki Mizoguchi; Masayuki Sakaki; Kazushige Inoue; Yasuhiko Kobayashi; Takashi Iwata; Yasuo Suehiro; Takuya Miura
Journal:  J Med Ultrason (2001)       Date:  2012-04-05       Impact factor: 1.314

Review 3.  Exercise hemodynamics in valvular heart disease.

Authors:  Anna M Booher; David S Bach
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

Review 4.  Sutureless aortic valve replacement.

Authors:  Marco Di Eusanio; Kevin Phan
Journal:  Ann Cardiothorac Surg       Date:  2015-03

5.  A mechanistic investigation of the EDWARDS INTUITY Elite valve's hemodynamic performance.

Authors:  Vahid Sadri; Charles H Bloodworth; Immanuel David Madukauwa-David; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Gen Thorac Cardiovasc Surg       Date:  2019-06-27

6.  Outcomes of surgical aortic valve replacement using Carpentier-Edwards PERIMOUNT bioprosthesis series in elderly patients with severe aortic valve stenosis: a retrospective cohort study.

Authors:  Naritomo Nishioka; Akira Yamada; Kosuke Ujihira; Yutaka Iba; Ryushi Maruyama; Eiichiro Hatta; Yoshihiko Kurimoto; Katsuhiko Nakanishi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-08-04

7.  New design bioprosthesis: early outcome of Carpentier-Edwards PERIMOUNT Magna in the small annular aortic position.

Authors:  Eiki Tayama; Yukihiro Tomita; Kazuyoshi Takagi; Tomokazu Kosuga; Hideki Teshima; Ken-ichi Imasaka; Hiromich Sonoda
Journal:  J Artif Organs       Date:  2011-06-21       Impact factor: 1.731

8.  Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method?

Authors:  Sabine Bleiziffer; Walter B Eichinger; Ina Hettich; Ralf Guenzinger; Daniel Ruzicka; Robert Bauernschmitt; Ruediger Lange
Journal:  Heart       Date:  2006-12-12       Impact factor: 5.994

9.  Late clinical outcomes of aortic valve replacement with Carpentier-Edwards pericardial valves.

Authors:  Hyoung Woo Chang; Wook Sung Kim; Joong Hyun Ahn; Keumhee C Carriere; Dong Seop Jeong; Yang Hyun Cho; Kiick Sung; Pyo Won Park
Journal:  J Thorac Dis       Date:  2019-12       Impact factor: 2.895

10.  Anatomical and functional changes after aortic valve replacement with different sizes of mechanical valves.

Authors:  Gokhan Ilhan; Sahin Bozok; Berkan Ozpak; Hakan Kara; Serkan Yazman; Serdar Bayrak; Ibrahim Ozsoyler; Ali Gurbuz
Journal:  Cardiovasc J Afr       Date:  2018-07-17       Impact factor: 0.802

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.