Literature DB >> 16022991

Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses.

Ching-Chi Hsu1, Ching-Kong Chao, Jaw-Lin Wang, Sheng-Mou Hou, Ying-Tsung Tsai, Jinn Lin.   

Abstract

Screw loosening can threaten pedicle screw fixation of the spine. Conical screws can improve the bending strength, but studies of their pullout strength as compared with that of cylindrical screws have shown wide variation. In the present study, polyurethane foam with two different densities (0.32 and 0.16 gm/cm3) was used to compare the pullout strength and stripping torque among three kinds of pedicle screws with different degrees of core tapering. Three-dimensional finite element models were also developed to compare the structural performance of these screws and to predict their pullout strength. In the mechanical tests, pullout strength was consistently higher in the higher density foam and was closely related to screw insertion torque (r=0.87 and 0.81 for the high and low density foam, respectively) and stripping torque (r=0.92 and 0.78, respectively). Conical core screws with effective foam compaction had significantly higher pullout strength and insertion torque than cylindrical core screws (p<0.05). The results of finite element analyses were closely related to those of the mechanical tests in both situations with or without foam compaction. This study led to three conclusions: polyurethane foam bone yielded consistent experimental results; screws with a conical core could significantly increase pullout strength and insertion torque over cylindrical; and finite element models could reliably reflect the results of mechanical tests.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 16022991     DOI: 10.1016/j.orthres.2004.11.002

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  29 in total

1.  Effect of surgical factors on the augmentation of cement-injectable cannulated pedicle screw fixation by a novel calcium phosphate-based nanocomposite.

Authors:  Haolin Sun; Chun Liu; Shunlun Chen; Yanjie Bai; Huilin Yang; Chunde Li; Lei Yang
Journal:  Front Med       Date:  2019-09-23       Impact factor: 4.592

2.  Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface.

Authors:  Patrícia Silva; Rodrigo César Rosa; Antonio Carlos Shimano; Helton L A Defino
Journal:  Eur Spine J       Date:  2013-05-08       Impact factor: 3.134

3.  The fates of pedicle screws and functional outcomes in a geriatric population following polymethylmethacrylate augmentation fixation for the osteoporotic thoracolumbar and lumbar burst fractures with mean ninety five month follow-up.

Authors:  Hsi-Hsien Lin; Ming-Chau Chang; Shih-Tien Wang; Chien-Lin Liu; Po-Hsin Chou
Journal:  Int Orthop       Date:  2018-02-11       Impact factor: 3.075

4.  Establishment and validation of a T12-L2 3D finite element model for thoracolumbar segments.

Authors:  Hui Lu; Qichuan Zhang; Fan Ding; Qimei Wu; Rong Liu
Journal:  Am J Transl Res       Date:  2022-03-15       Impact factor: 4.060

5.  Deterioration of the fixation segment's stress distribution and the strength reduction of screw holding position together cause screw loosening in ALSR fixed OLIF patients with poor BMD.

Authors:  Jing-Chi Li; Zhi-Qiang Yang; Tian-Hang Xie; Zhe-Tao Song; Yue-Ming Song; Jian-Cheng Zeng
Journal:  Front Bioeng Biotechnol       Date:  2022-08-30

6.  The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength.

Authors:  Rômulo Pedroza Pinheiro; Raffaello de Freitas Miranda; Antonio Carlos Shimano; Thibault Chandanson; Keri George; Helton L A Defino
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2022-01-21

7.  The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically.

Authors:  Jing-Chi Li; Tian-Hang Xie; Zhuang Zhang; Zhe-Tao Song; Yue-Ming Song; Jian-Cheng Zeng
Journal:  Front Bioeng Biotechnol       Date:  2022-04-08

8.  EFFECT OF PILOT HOLE TAPPING ON PULLOUT STRENGTH AND INSERTION TORQUE OF DUAL CORE PEDICLE SCREWS.

Authors:  Rodrigo César Rosa; Patrícia Silva; Maurício José Falcai; Antônio Carlos Shimano; Helton Luiz Aparecido Defino
Journal:  Rev Bras Ortop       Date:  2015-11-16

9.  Analysis of primary stability of dental implants inserted in different substrates using the pullout test and insertion torque.

Authors:  Nathalia Ferraz Oliscovicz; Antônio Carlos Shimano; Elcio Marcantonio Junior; César Penazzo Lepri; Andréa Candido Dos Reis
Journal:  Int J Dent       Date:  2013-01-22

10.  Comparison and prediction of pullout strength of conical and cylindrical pedicle screws within synthetic bone.

Authors:  Wen-Chi Tsai; Po-Quang Chen; Tung-Wu Lu; Shing-Sheng Wu; Kao-Shang Shih; Shang-Chih Lin
Journal:  BMC Musculoskelet Disord       Date:  2009-04-30       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.