Literature DB >> 16020554

MR angiography of aortoiliac occlusive disease: a phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325.

Mathias Goyen1, Mark Edelman, Pierre Perreault, Elaine O'Riordan, Hernan Bertoni, James Taylor, Daniel Siragusa, Melhem Sharafuddin, Emile R Mohler, Robert Breger, E Kent Yucel, Kohkan Shamsi, Robert M Weisskoff.   

Abstract

PURPOSE: To evaluate prospectively the safety and effectiveness of aortoiliac magnetic resonance (MR) angiography enhanced with MS-325 (gadofosveset trisodium) at a dose of 0.03 mmol/kg; effectiveness was defined as accuracy relative to the reference standard, conventional angiography.
MATERIALS AND METHODS: Study was approved by institutional review boards of participating institutions, and required national approvals were obtained. Study protocol conformed to Good Clinical Practice guidelines, and informed patient consent was obtained. Patients with known or suspected peripheral vascular disease received 0.03 mmol/kg MS-325 for aortoiliac MR angiography. They were also examined with conventional angiography. MS-325-enhanced MR was evaluated for safety and effectiveness. Along with unenhanced two-dimensional time-of-flight MR angiography, it was compared with conventional angiography for presence of vascular stenosis. Student t tests were used to identify significant improvement in diagnostic sensitivity, specificity, and accuracy, as well as quantitative characterization of stenoses by three blinded readers. Correlations between readers of conventional angiograms were calculated and compared with MR results.
RESULTS: In 174 patients, MS-325-enhanced MR angiography showed significant improvement (P < or = .001) in sensitivity, specificity, and accuracy for diagnosis of clinically significant (> or =50%) stenosis, compared with unenhanced MR. For all readers, areas under the receiver operating characteristic curve for both quantitative and qualitative measures of significant disease increased (P < .001) for MS-325-enhanced MR compared with time-of-flight MR. All readers also expressed higher confidence in diagnosis (P < .001) and found fewer images uninterpretable with MS-325 enhancement. All measures of interpretation accuracy approached corresponding measures of correlation between readers of conventional angiograms. Incidence of severe and serious adverse events with MS-325 was low. No patients were withdrawn from study due to adverse events or abnormalities in laboratory results. There were no clinically important trends in findings at hematology, blood chemistry, urinalysis, electrocardiography, or physical examination.
CONCLUSION: MR angiography with MS-325 provides significant improvement in effectiveness over unenhanced MR (and minimal and transient side effects) at a dose of 0.03 mmol/kg and was safe and effective for MR evaluation of patients with aortoiliac occlusive disease.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16020554     DOI: 10.1148/radiol.2363040577

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  16 in total

Review 1.  Targeted probes for cardiovascular MRI.

Authors:  Ritika Uppal; Peter Caravan
Journal:  Future Med Chem       Date:  2010-03       Impact factor: 3.808

Review 2.  MRA of abdominal vessels: technical advances.

Authors:  Henrik J Michaely; Olaf Dietrich; Kambiz Nael; Sabine Weckbach; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-05-24       Impact factor: 5.315

Review 3.  Macromolecules, dendrimers, and nanomaterials in magnetic resonance imaging: the interplay between size, function, and pharmacokinetics.

Authors:  Aaron Joseph L Villaraza; Ambika Bumb; Martin W Brechbiel
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

Review 4.  Blood pool contrast agents for venous magnetic resonance imaging.

Authors:  Irai S Oliveira; Sandeep S Hedgire; Weier Li; Suvranu Ganguli; Anand M Prabhakar
Journal:  Cardiovasc Diagn Ther       Date:  2016-12

5.  Structure - relaxivity relationships among targeted MR contrast agents.

Authors:  Peter Caravan; Zhaoda Zhang
Journal:  Eur J Inorg Chem       Date:  2012-04       Impact factor: 2.524

Review 6.  Extracardiac applications of MR blood pool contrast agent in children.

Authors:  Shannon G Farmakis; Geetika Khanna
Journal:  Pediatr Radiol       Date:  2014-11-19

Review 7.  High-relaxivity contrast-enhanced magnetic resonance neuroimaging: a review.

Authors:  Frederik L Giesel; Amit Mehndiratta; Marco Essig
Journal:  Eur Radiol       Date:  2010-06-23       Impact factor: 5.315

Review 8.  MR imaging probes: design and applications.

Authors:  Eszter Boros; Eric M Gale; Peter Caravan
Journal:  Dalton Trans       Date:  2015-03-21       Impact factor: 4.390

Review 9.  Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers.

Authors:  Jessica Wahsner; Eric M Gale; Aurora Rodríguez-Rodríguez; Peter Caravan
Journal:  Chem Rev       Date:  2018-10-16       Impact factor: 60.622

10.  T1 relaxivity of core-encapsulated gadolinium liposomal contrast agents--effect of liposome size and internal gadolinium concentration.

Authors:  Ketan Ghaghada; Catherine Hawley; Keigo Kawaji; Ananth Annapragada; Srinivasan Mukundan
Journal:  Acad Radiol       Date:  2008-10       Impact factor: 3.173