Cochlear implant soft failures consensus development conference statement.

T J Balkany1, A V Hodges, C A Buchman, W M Luxford, C H Pillsbury, P S Roland, J K Shallop, D D Backous, D Franz, J M Graham, B Hirsch, M Luntz, J K Niparko, J Patrick, S L Payne, F F Telischi, E A Tobey, E Truy, S Staller.   

Abstract

Mesh:

Year:  2005        PMID: 16015190     DOI: 10.1097/01.mao.0000178150.44505.52

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


× No keyword cloud information.
  15 in total

1.  Foreign body or hypersensitivity granuloma of the inner ear after cochlear implantation: one possible cause of a soft failure?

Authors:  Joseph B Nadol; Donald K Eddington; Barbara J Burgess
Journal:  Otol Neurotol       Date:  2008-12       Impact factor: 2.311

2.  Detecting soft failures in pediatric cochlear implants: relating behavior to language outcomes.

Authors:  Aaron C Moberly; D Bradley Welling; Susan Nittrouer
Journal:  Otol Neurotol       Date:  2013-12       Impact factor: 2.311

3.  Long-term results of the transattical approach: an alternative technique for cochlear implantation.

Authors:  Miguel Vaca; Auxiliadora Gutiérrez; Rubén Polo; Antonio Alonso; Felipe Álvarez
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-11-29       Impact factor: 2.503

Review 4.  Surgery of the ear and the lateral skull base: pitfalls and complications.

Authors:  Bernhard Schick; Julia Dlugaiczyk
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2013-12-13

5.  International classification of reliability for implanted cochlear implant receiver stimulators.

Authors:  Rolf-Dieter Battmer; Douglas D Backous; Thomas J Balkany; Robert J S Briggs; Bruce J Gantz; Andrew van Hasselt; Chong Sun Kim; Takeshi Kubo; Thomas Lenarz; Harold C Pillsbury; Gerard M O'Donoghue
Journal:  Otol Neurotol       Date:  2010-10       Impact factor: 2.311

6.  Multicenter evaluation of Neurelec Digisonic® SP cochlear implant reliability.

Authors:  Luminiţa Rădulescu; Sebastian Cozma; Casimir Niemczyk; Nicolas Guevara; Ivan Gahide; John Economides; Jean-Pierre Lavieille; Renaud Meller; Jean-Pierre Bébéar; Emilien Radafy; Philippe Bordure; Djamel Djennaoui; Eric Truy
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-11-18       Impact factor: 2.503

7.  Middle Ear Disease and Cochlear Implant Function: A Case Study.

Authors:  Joshua F Dixon; Jennifer B Shinn; Meg Adkins; Bryan D Hardin; Matthew L Bush
Journal:  Hearing Balance Commun       Date:  2014-06-11

8.  HiRes Ultra Series Recall: Failure Rates and Revision Speech Recognition Outcomes.

Authors:  Nathan R Lindquist; Nathan D Cass; Ankita Patro; Elizabeth L Perkins; René H Gifford; David S Haynes; Jourdan T Holder
Journal:  Otol Neurotol       Date:  2022-08-01       Impact factor: 2.619

Review 9.  Advances in cochlear implant telemetry: evoked neural responses, electrical field imaging, and technical integrity.

Authors:  Lucas H M Mens
Journal:  Trends Amplif       Date:  2007-09

10.  Facial nerve stimulation after cochlear implantation: our experience.

Authors:  S Berrettini; De A Vito; L Bruschini; S Passetti; F Forli
Journal:  Acta Otorhinolaryngol Ital       Date:  2011-02       Impact factor: 2.124