Literature DB >> 16003664

Interobserver reproducibility of the visual estimation of range of motion of the shoulder.

Caroline B Terwee1, Andrea F de Winter, Rob J Scholten, Marielle P Jans, Walter Devillé, Dirkjan van Schaardenburg, Lex M Bouter.   

Abstract

OBJECTIVES: To assess interobserver reproducibility (agreement and reliability) of visually estimated shoulder range of motion (ROM) and to study the influence of clinical characteristics on the reproducibility.
DESIGN: Test-retest analyses.
SETTING: Various health care settings in the Netherlands. PARTICIPANTS: Consecutive patients with shoulder complaints (N = 201) referred by 20 general practitioners, 2 orthopedic physicians, and 20 rheumatologists.
INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Independent visual estimation by 2 physiotherapists of the ROM. Agreement was calculated as the mean difference in visual estimation between examiners +/-1.96 x standard deviations of this mean difference. The intraclass correlation coefficient (ICC) was calculated as a measure of reliability, based on a 2-way random effects analysis of variance.
RESULTS: The lowest level of agreement was for visual estimation of active and passive elevation (limits of agreement, -43.4 to 39.8 and -46.7 to 41.5, respectively, for the difference between the affected and contralateral sides), for which the level of agreement was most clearly associated with pain severity and disability. The ability to differentiate between subjects was acceptable for all movements for the difference between the affected and contralateral sides (ICCs, > .70) except for horizontal adduction (ICC = .49).
CONCLUSIONS: Interobserver agreement was low for the assessment of active and passive elevation, especially for patients with a high pain severity and disability. Except for horizontal adduction, visual estimation seems suitable for distinguishing differences between affected and contralateral ROM between subjects.

Entities:  

Mesh:

Year:  2005        PMID: 16003664     DOI: 10.1016/j.apmr.2004.12.031

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  15 in total

1.  Validity of goniometric elbow measurements: comparative study with a radiographic method.

Authors:  Julien Chapleau; Fanny Canet; Yvan Petit; G-Yves Laflamme; Dominique M Rouleau
Journal:  Clin Orthop Relat Res       Date:  2011-07-21       Impact factor: 4.176

2.  Objective assessment of shoulder mobility with a new 3D gyroscope--a validation study.

Authors:  Bilal Farouk El-Zayat; Turgay Efe; Annett Heidrich; Udo Wolf; Nina Timmesfeld; Thomas J Heyse; Stefan Lakemeier; Susanne Fuchs-Winkelmann; Markus D Schofer
Journal:  BMC Musculoskelet Disord       Date:  2011-07-21       Impact factor: 2.362

3.  INTER-RATER AGREEMENT AND VALIDITY OF A TACKLING PERFORMANCE ASSESSMENT SCALE IN YOUTH AMERICAN FOOTBALL.

Authors:  Eric Schussler; Richard J Jagacinski; Susan E White; Ajit M Chaudhari; John A Buford; James A Onate
Journal:  Int J Sports Phys Ther       Date:  2018-04

4.  Passive range of motion in patients with adhesive shoulder capsulitis, an intertester reliability study over eight weeks.

Authors:  Satya Pal Sharma; Anders Bærheim; Alice Kvåle
Journal:  BMC Musculoskelet Disord       Date:  2015-02-22       Impact factor: 2.362

5.  Validity and reliability of arm abduction angle measured on smartphone: a cross-sectional study.

Authors:  Antonio I Cuesta-Vargas; Cristina Roldán-Jiménez
Journal:  BMC Musculoskelet Disord       Date:  2016-02-20       Impact factor: 2.362

6.  Studying Upper-Limb Kinematics Using Inertial Sensors Embedded in Mobile Phones.

Authors:  Cristina Roldan-Jimenez; Antonio Cuesta-Vargas; Paul Bennett
Journal:  JMIR Rehabil Assist Technol       Date:  2015-05-20

7.  Reproducibility of a 3-dimensional gyroscope in measuring shoulder anteflexion and abduction.

Authors:  Ludo I F Penning; Nick A Guldemond; Rob A de Bie; Geert H I M Walenkamp
Journal:  BMC Musculoskelet Disord       Date:  2012-07-30       Impact factor: 2.362

8.  Objective assessment, repeatability, and agreement of shoulder ROM with a 3D gyroscope.

Authors:  Bilal Farouk El-Zayat; Turgay Efe; Annett Heidrich; Robert Anetsmann; Nina Timmesfeld; Susanne Fuchs-Winkelmann; Markus Dietmar Schofer
Journal:  BMC Musculoskelet Disord       Date:  2013-02-26       Impact factor: 2.362

9.  Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty.

Authors:  Anton F Lenssen; Ellen M van Dam; Yvonne H F Crijns; Mark Verhey; Ruud J T Geesink; Piet A van den Brandt; Rob A de Bie
Journal:  BMC Musculoskelet Disord       Date:  2007-08-17       Impact factor: 2.362

10.  Range of shoulder motion in patients with adhesive capsulitis; intra-tester reproducibility is acceptable for group comparisons.

Authors:  Einar Kristian Tveitå; Ole Marius Ekeberg; Niels Gunnar Juel; Erik Bautz-Holter
Journal:  BMC Musculoskelet Disord       Date:  2008-04-12       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.