Literature DB >> 15976983

Inappropriate implantable cardioverter defibrillator shock from a transcutaneous muscle stimulation device therapy.

Chung-Wah Siu1, Hung-Fat Tse, Chu-Pak Lau.   

Abstract

Inappropriate shock from implantable cardioverter defibrillator (ICD) may result from external electromagnetic interference (EMI), especially for unipolar ventricle sensing. Previous case reports and small in-vitro safety study suggested that endocardial bipolar lead system may be immune from EMI resulting from transcutaneous electrical neuromuscle stimulation (TENS) therapy. This report presents an unusual case of inappropriate discharge in a patient with ICD of endocardial bipolar lead system, receiving TENS from a commercially available device.

Entities:  

Mesh:

Year:  2005        PMID: 15976983     DOI: 10.1007/s10840-005-0357-3

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  4 in total

1.  Electromagnetic interference by transcutaneous neuromuscular electrical stimulation in patients with bipolar sensing implantable cardioverter defibrillators: a pilot safety study.

Authors:  Richard Crevenna; Günter Stix; Johannes Pleiner; Thomas Pezawas; Herwig Schmidinger; Michael Quittan; Michael Wolzt
Journal:  Pacing Clin Electrophysiol       Date:  2003-02       Impact factor: 1.976

2.  Adverse events with transvenous implantable cardioverter-defibrillators: a prospective multicenter study. European 7219 Jewel ICD investigators.

Authors:  M Rosenqvist; T Beyer; M Block; K den Dulk; J Minten; F Lindemans
Journal:  Circulation       Date:  1998-08-18       Impact factor: 29.690

3.  Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: experience from stored electrograms of implantable cardioverter-defibrillators.

Authors:  R Rüppel; C A Schlüter; S Boczor; T Meinertz; M Schlüter; K H Kuck; R Cappato
Journal:  J Am Coll Cardiol       Date:  1998-11-15       Impact factor: 24.094

4.  Electromagnetic interference from a muscle stimulation device causing discharge of an implantable cardioverter defibrillator: epicardial bipolar and endocardial bipolar sensing circuits are compared.

Authors:  T V Glotzer; M Gordon; M Sparta; G Radoslovich; J Zimmerman
Journal:  Pacing Clin Electrophysiol       Date:  1998-10       Impact factor: 1.976

  4 in total
  7 in total

Review 1.  [Perioperative management of patients with implanted pacemakers or cardioverter/defibrillators. Recommendations of the Austrian Society for Anaesthesiology, Resuscitation and Intensive Care Medicine, the Austrian Society for Cardiology and the Austrian Society for Surgery].

Authors:  H Gombotz; M Anelli Monti; N Leitgeb; M Nürnberg; B Strohmer
Journal:  Anaesthesist       Date:  2009-05       Impact factor: 1.041

2.  Inappropriate ICD discharge induced by electrical interference from a physio-therapeutic muscle stimulation device.

Authors:  H Nägele; M Azizi
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2006-09

3.  Sudden cardiac death after myocardial infarction in type 2 diabetic patients with no residual myocardial ischemia.

Authors:  Chun-Yip Yeung; Karen Siu-Ling Lam; Sheung-Wai Li; Kwok-Fai Lam; Hung-Fat Tse; Chung-Wah Siu
Journal:  Diabetes Care       Date:  2012-08-08       Impact factor: 19.112

Review 4.  Neuromuscular electrical stimulation of the thighs in cardiac patients with implantable cardioverter defibrillators.

Authors:  Fadime Cenik; Dieter Schoberwalter; Mohammad Keilani; Bruno Maehr; Michael Wolzt; Maximilian Marhold; Richard Crevenna
Journal:  Wien Klin Wochenschr       Date:  2016-07-25       Impact factor: 1.704

5.  Multiple inappropriate implantable cardiac defibrillator therapies in rapid succession.

Authors:  Jeffrey A Marbach; Colin Yeo; Martin S Green; Girish M Nair
Journal:  Clin Case Rep       Date:  2017-10-23

6.  The safety of electrical stimulation in patients with pacemakers and implantable cardioverter defibrillators: A systematic review.

Authors:  James Badger; Paul Taylor; Ian Swain
Journal:  J Rehabil Assist Technol Eng       Date:  2017-12-05

7.  An "UninTENSional" Subcutaneous Implantable Cardioverter-defibrillator Shock.

Authors:  Suzette L Turner; Sheldon M Singh
Journal:  J Innov Card Rhythm Manag       Date:  2018-11-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.