Literature DB >> 15976976

Safety and feasibility of coronary sinus left ventricular leads extraction: a preliminary report.

Giuseppe De Martino1, Serafino Orazi, Giovanni Bisignani, Salvatore Toscano, Loredana Messano, Quintino Parisi, Matteo Santamaria, Gemma Pelargonio, Antonio Dello Russo, Fulvio Bellocci, Paolo Zecchi, Filippo Crea.   

Abstract

BACKGROUND: transvenous positioning of the left ventricular (LV) lead in a branch of the coronary sinus (CS) is generally the preferred implantation technique in biventricular pacing. Very few data are reported about removal of LV pacing leads positioned in a CS branch. Aim of the study was to describe our experience with percutaneous extraction of LV pacing leads in order to evaluate feasibility and safety of this procedure.
METHODS: we enrolled 392 patients who underwent a biventricular pacing implant. The indication for catheter removal was considered in case of definite diagnosis of infection and in some cases of lead dislodgement or diaphragmatic stimulation. LV lead extraction was first attempted by manual traction; in case of failure a locking stylet or locking stylet plus radiofrequency could be used.
RESULTS: twelve of 392 patients implanted needed LV lead removal. The leads had been in place for 13.9 +/- 11.7 months. Extraction was indicated in 5 of them for LV lead dislodgement or diaphragmatic stimulation, and in 7 patients for lead infection. In all cases manual traction succeeded to remove the LV lead. In 7 cases of infection, the right atrial and ventricular leads were removed. The mean total procedure time was 69 +/- 22 min. No complications were observed.
CONCLUSIONS: our study suggests that CS leads could be easily and safely removed without any complication, also when placed in a CS branch, at least for relatively young catheters.

Entities:  

Mesh:

Year:  2005        PMID: 15976976     DOI: 10.1007/s10840-005-0910-0

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  7 in total

Review 1.  Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty.

Authors:  C J Love; B L Wilkoff; C L Byrd; P H Belott; J A Brinker; N E Fearnot; R A Friedman; S Furman; L B Goode; D L Hayes; D T Kawanishi; V Parsonnet; C Reiser; H J Van Zandt
Journal:  Pacing Clin Electrophysiol       Date:  2000-04       Impact factor: 1.976

2.  Cardiac resynchronization in chronic heart failure.

Authors:  William T Abraham; Westby G Fisher; Andrew L Smith; David B Delurgio; Angel R Leon; Evan Loh; Dusan Z Kocovic; Milton Packer; Alfredo L Clavell; David L Hayes; Myrvin Ellestad; Robin J Trupp; Jackie Underwood; Faith Pickering; Cindy Truex; Peggy McAtee; John Messenger
Journal:  N Engl J Med       Date:  2002-06-13       Impact factor: 91.245

Review 3.  Pacemaker and defibrillator lead extraction.

Authors:  Steven P Kutalek
Journal:  Curr Opin Cardiol       Date:  2004-01       Impact factor: 2.161

4.  Permanent left ventricular pacing with transvenous leads inserted into the coronary veins.

Authors:  J C Daubert; P Ritter; H Le Breton; D Gras; C Leclercq; A Lazarus; J Mugica; P Mabo; S Cazeau
Journal:  Pacing Clin Electrophysiol       Date:  1998-01       Impact factor: 1.976

5.  Coronary sinus lead extraction.

Authors:  G Frank O Tyers; Jacquie Clark; Yan Wang; Pauline Mills; Jamil Bashir
Journal:  Pacing Clin Electrophysiol       Date:  2003-01       Impact factor: 1.976

6.  Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay.

Authors:  S Cazeau; C Leclercq; T Lavergne; S Walker; C Varma; C Linde; S Garrigue; L Kappenberger; G A Haywood; M Santini; C Bailleul; J C Daubert
Journal:  N Engl J Med       Date:  2001-03-22       Impact factor: 91.245

7.  New criteria for diagnosis of infective endocarditis: utilization of specific echocardiographic findings. Duke Endocarditis Service.

Authors:  D T Durack; A S Lukes; D K Bright
Journal:  Am J Med       Date:  1994-03       Impact factor: 4.965

  7 in total
  4 in total

1.  Outcomes and predictors of difficulty with coronary sinus lead removal.

Authors:  Seth Sheldon; Paul A Friedman; David L Hayes; Michael J Osborn; Yong-Mei Cha; Robert F Rea; Samuel J Asirvatham
Journal:  J Interv Card Electrophysiol       Date:  2012-05-15       Impact factor: 1.900

Review 2.  Extraction of implantable cardiac electronic devices.

Authors:  John Rickard; Bruce L Wilkoff
Journal:  Curr Cardiol Rep       Date:  2011-10       Impact factor: 2.931

3.  Abolition of diaphragmatic stimulation and restoration of left ventricular pacing by nonsurgical withdrawal of the left ventricular lead: Report of two cases.

Authors:  Joaquín Fernández de la Concha Castañeda; Juan José García Guerrero; Mercedes Merchán Cuenda; Manuel Doblado Calatrava
Journal:  HeartRhythm Case Rep       Date:  2017-12-27

4.  Safety and effectiveness of coronary sinus leads extraction - single high-volume centre experience.

Authors:  Andrzej W Kutarski; Wojciech Jacheć; Łukasz Tułecki; Konrad Tomków; Paweł Stefańczyk; Wojciech Borzęcki; Dorota Nowosielecka; Marek Czajkowski; Maciej Polewczyk; Anna Polewczyk
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-09-18       Impact factor: 1.426

  4 in total