Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty.

C J Love, B L Wilkoff, C L Byrd, P H Belott, J A Brinker, N E Fearnot, R A Friedman, S Furman, L B Goode, D L Hayes, D T Kawanishi, V Parsonnet, C Reiser, H J Van Zandt.   

Abstract

The procedure of lead removal has recently matured into a definable, teachable art with its own specific tools and techniques. It is now time to recognize and formalize the practice of lead removal according to the current methods of medicine and the health care industry. In addition, since at this time the only prospective scientific study of lead extraction is the PLEXES trial, we suggest that studies relating to the techniques of and indications for lead extraction be designed. Recommendations for a common set of definitions, for a framework of training and reviewing physicians in the art, for general methods of reimbursement, and for consistency among clinical trials have been made. Implementation of these recommendations will require additional effort and cooperation from practicing physicians, medical societies, hospital administrations, and industry.

Mesh:

Year:  2000        PMID: 10793452     DOI: 10.1111/j.1540-8159.2000.tb00845.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  40 in total

Review 1.  Pacemaker lead complications: when is extraction appropriate and what can we learn from published data?

Authors:  F A Bracke; A Meijer; L M van Gelder
Journal:  Heart       Date:  2001-03       Impact factor: 5.994

2.  Determinants of procedural outcome of chronically implanted pacemaker and defibrillator leads using the Excimer laser sheath.

Authors:  C A Rinaldi; J Bostock; N Patel; C A Bucknall
Journal:  Heart       Date:  2002-02       Impact factor: 5.994

3.  Replacement of extracted permanent pacemaker or defibrillator leads by cannulation of veins using the femoral "drag through" technique.

Authors:  R J Schilling
Journal:  Heart       Date:  2002-03       Impact factor: 5.994

Review 4.  Advances in device lead extraction.

Authors:  C L Byrd
Journal:  Curr Cardiol Rep       Date:  2001-07       Impact factor: 2.931

5.  The use of radiofrequency catheter ablation to extract a chronic permanent pacemaker lead after failed laser extraction.

Authors:  Deepak Roshan Talreja; Samuel Asirvatham; David L Hayes
Journal:  J Interv Card Electrophysiol       Date:  2002-06       Impact factor: 1.900

6.  Symptomatic occlusion of the access vein after pacemaker or ICD lead extraction.

Authors:  F A Bracke; A Meijer; L M Van Gelder
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

7.  Local symptoms at the site of pacemaker implantation indicate latent systemic infection.

Authors:  D Klug; F Wallet; D Lacroix; C Marquié; C Kouakam; S Kacet; R Courcol
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

8.  Surgical removal of infected pacemaker leads without cardiopulmonary bypass after failed extraction using the Excimer Laser Sheath Extraction System.

Authors:  Chiho Tokunaga; Yoshiharu Enomoto; Fujio Sato; Shinya Kanemoto; Shonosuke Matsushita; Yuji Hiramatsu; Kazutaka Aonuma; Yuzuru Sakakibara
Journal:  J Artif Organs       Date:  2011-09-23       Impact factor: 1.731

9.  Repositioning of a dislodged and fibrosed ventricular lead.

Authors:  Ejaz M Khan; Apostolos A Voudouris; R E Hood; Stephen R Shorofsky
Journal:  J Interv Card Electrophysiol       Date:  2005-06       Impact factor: 1.900

10.  Severe tricuspid valve stenosis secondary to pacemaker leads presenting as ascites and liver dysfunction: a complex problem requiring a multidisciplinary therapeutic approach.

Authors:  Anita Krishnan; Achintya Moulick; Pranava Sinha; Karen Kuehl; Joshua Kanter; Michael Slack; Jonathan Kaltman; Marco Mercader; Jeffrey P Moak
Journal:  J Interv Card Electrophysiol       Date:  2008-10-11       Impact factor: 1.900