Literature DB >> 15976097

Multiplexed analysis of biomarkers related to obesity and the metabolic syndrome in human plasma, using the Luminex-100 system.

Mine Y Liu1, Antonios M Xydakis, Ron C Hoogeveen, Peter H Jones, E O'Brian Smith, Kathleen W Nelson, Christie M Ballantyne.   

Abstract

BACKGROUND: The complex pathology of disease has sparked the development of novel protein expression profiling techniques that require validation in clinical settings. This study focuses on multiplexed analyses of adipocytokines and biomarkers linked to the metabolic syndrome, diabetes, and cardiovascular disease.
METHODS: Multiplexed immunoassays using fluorescent microspheres and the Luminex-100 system were performed on plasma from 80 obese patients (40 with the metabolic syndrome) before and after 6-8 weeks of diet-induced weight loss. Leptin, insulin, C-peptide, monocyte chemoattractant protein-1 (MCP-1), eotaxin, interleukin-8 (IL-8), tumor necrosis factor-alpha (TNF-alpha), and IL-6 concentrations measured with multiplex panels from 3 different manufacturers were compared with results from commercial ELISAs. Detection limits and between- and within-run imprecision were determined for each analyte. Bland-Altman analysis was used to determine agreement between multiplexed immunoassays and ELISAs.
RESULTS: Correlation between the Luminex multiplexed assays and ELISAs was good for leptin (Linco), insulin (Linco), MCP-1 (Biosource and Upstate), and eotaxin (Biosource) with correlation coefficients of 0.711-0.895; fair for eotaxin (Upstate) and C-peptide (Linco) with correlation coefficients of 0.496-0.582; and poor for TNF-alpha, IL-8, and IL-6 (Linco, Biosource, Upstate, and R&D) with correlation coefficients of -0.107 to 0.318. Within- and between-run imprecision values for the multiplex method were generally <15%. Relative changes in plasma leptin and insulin concentrations after diet-induced weight loss were similar whether assessed by multiplex assay or ELISA.
CONCLUSION: Although this technology appears useful in clinical research studies, low assay sensitivity and poor correlations with conventional ELISA methods for some analytes with very low plasma concentrations should be considered when using the Luminex platform in clinical studies.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15976097     DOI: 10.1373/clinchem.2004.047084

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  42 in total

1.  Circulating cytokines and risk of B-cell non-Hodgkin lymphoma: a prospective study.

Authors:  Yian Gu; Roy E Shore; Alan A Arslan; Karen L Koenig; Mengling Liu; Sherif Ibrahim; Anna E Lokshin; Anne Zeleniuch-Jacquotte
Journal:  Cancer Causes Control       Date:  2010-04-07       Impact factor: 2.506

Review 2.  Biomarker method validation in anticancer drug development.

Authors:  J Cummings; T H Ward; A Greystoke; M Ranson; C Dive
Journal:  Br J Pharmacol       Date:  2007-09-17       Impact factor: 8.739

3.  Multiplex bead array assays: performance evaluation and comparison of sensitivity to ELISA.

Authors:  Mohamed F Elshal; J Philip McCoy
Journal:  Methods       Date:  2006-04       Impact factor: 3.608

4.  Optimization and qualification of a multiplex bead array to assess cytokine and chemokine production by vaccine-specific cells.

Authors:  Olivier D Defawe; Youyi Fong; Evgenia Vasilyeva; Melissa Pickett; Donald K Carter; Erin Gabriel; Supachai Rerks-Ngarm; Sorachai Nitayaphan; Nicole Frahm; M Juliana McElrath; Stephen C De Rosa
Journal:  J Immunol Methods       Date:  2012-05-22       Impact factor: 2.303

5.  Measurement of Leptin by RIA Versus MIA in a Population of Healthy Newborns.

Authors:  Consuelo Treviño-Garza; Leonardo Mancillas-Adame; Cynthia M Estrada-Zúñiga; Jesús Z Villarreal-Pérez; Laura Villarreal-Martinez; Manuel E De la O-Cavazos
Journal:  J Clin Lab Anal       Date:  2015-03-26       Impact factor: 2.352

6.  A multiplexed immunoaggregation biomarker assay using a two-stage micro resistive pulse sensor.

Authors:  Y Han; H Wu; F Liu; G Cheng; J Zhe
Journal:  Biomicrofluidics       Date:  2016-03-16       Impact factor: 2.800

Review 7.  Early diagnosis of disease using microbead array technology: A review.

Authors:  Sanam Foroutan Parsa; Atieh Vafajoo; Azin Rostami; Reza Salarian; Mohammad Rabiee; Navid Rabiee; Ghazal Rabiee; Mohammadreza Tahriri; Amir Yadegari; Daryoosh Vashaee; Lobat Tayebi; Michael R Hamblin
Journal:  Anal Chim Acta       Date:  2018-05-04       Impact factor: 6.558

8.  Increased levels of interleukin-33 in gingival crevicular fluids of patients with chronic periodontitis.

Authors:  Mehmet Sağlam; Serhat Köseoğlu; Cüneyt Asım Aral; Levent Savran; Tuğba Pekbağrıyanık; Ayşe Çetinkaya
Journal:  Odontology       Date:  2016-06-30       Impact factor: 2.634

9.  Acute ingestion of a novel whey-derived peptide improves vascular endothelial responses in healthy individuals: a randomized, placebo controlled trial.

Authors:  Kevin D Ballard; Richard S Bruno; Richard L Seip; Erin E Quann; Brittanie M Volk; Daniel J Freidenreich; Diana M Kawiecki; Brian R Kupchak; Min-Yu Chung; William J Kraemer; Jeff S Volek
Journal:  Nutr J       Date:  2009-07-22       Impact factor: 3.271

10.  Meso scale discovery and luminex comparative analysis of calbindin D28K.

Authors:  Samer Sourial; Maritha Marcusson-Ståhl; Karin Cederbrant
Journal:  J Biomed Biotechnol       Date:  2009-10-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.