During angiography, blood flow is visualized with a radiopaque contrast agent, which is denser than blood. In complex vasculature, such as cerebral saccular aneurysms, the density difference may produce an appreciable gravity effect, where the contrast material separates from blood and settles along the gravity direction. Although contrast settling has been occasionally reported before, the fluid mechanics behind it have not been explored. Furthermore, the severity of contrast settling in cerebral aneurysms varies significantly from case to case. Therefore, a better understanding of the physical principles behind this phenomenon is needed to evaluate contrast settling in clinical angiography. In this study, flow in two identical groups of sidewall aneurysm models with varying parent-vessel curvature was examined by angiography. Intravascular stents were deployed into one group of the models. To detect contrast settling, we used lateral view angiography. Time-intensity curves were analysed from the angiographic data, and a computational fluid dynamic analysis was conducted. Results showed that contrast settling was strongly related to the local flow dynamics. We used the Froude number, a ratio of flow inertia to gravity force, to characterize the significance of gravity force. An aneurysm with a larger vessel curvature experienced higher flow, which resulted in a larger Froude number and, thus, less gravitational settling. Addition of a stent reduced the aneurysmal flow, thereby increasing the contrast settling. We found that contrast settling resulted in an elevated washout tail in the time-intensity curve. However, this signature is not unique to contrast settling. To determine whether contrast settling is present, a lateral view should be obtained in addition to the anteroposterior (AP) view routinely used clinically so as to rule out contrast settling and hence to enable a valid time-intensity curve analysis of blood flow in the aneurysm.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15972988     DOI: 10.1088/0031-9155/50/13/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Porcine In Vivo Validation of a Virtual Contrast Model: The Influence of Contrast Agent Properties and Vessel Flow Rates.

Authors:  T W Peach; Y Ventikos; J V Byrne; Z You
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-07       Impact factor: 3.825

2.  The mixability of angiographic contrast with arterial blood.

Authors:  Baruch B Lieber; Chander Sadasivan; Qing Hao; Jaehoon Seong; Liliana Cesar
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

3.  The natural history of "contrast stasis" within aneurysm after embolization.

Authors:  Mohamed M Abdihalim; Saqib A Chaudry; Nauman Tariq; M Fareed K Suri; Adnan I Qureshi
Journal:  J Vasc Interv Neurol       Date:  2013-02

4.  Flow modification in canine intracranial aneurysm model by an asymmetric stent: studies using digital subtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses.

Authors:  Yiemeng Hoi; Ciprian N Ionita; Rekha V Tranquebar; Kenneth R Hoffmann; Scott H Woodward; Dale B Taulbee; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-03-13

5.  Measurement of quantifiable parameters by time-density curves in the elastase-induced aneurysm model: first results in the comparison of a flow diverter and a conventional aneurysm stent.

Authors:  Tobias Struffert; Sabine Ott; Markus Kowarschik; Frederik Bender; Edyta Adamek; Tobias Engelhorn; Philipp Gölitz; Stefan Lang; Charles M Strother; Arnd Doerfler
Journal:  Eur Radiol       Date:  2012-08-16       Impact factor: 5.315

6.  Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting.

Authors:  H Meng; Z Wang; M Kim; R D Ecker; L N Hopkins
Journal:  AJNR Am J Neuroradiol       Date:  2006-10       Impact factor: 3.825

7.  3D rotational digital subtraction angiography may underestimate intracranial aneurysms: findings from two basilar aneurysms.

Authors:  L-D Jou; A Mohamed; D H Lee; M E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

8.  The asymmetric vascular stent: efficacy in a rabbit aneurysm model.

Authors:  Ciprian N Ionita; Ann M Paciorek; Andreea Dohatcu; Kenneth R Hoffmann; Daniel R Bednarek; John Kolega; Elad I Levy; L Nelson Hopkins; Stephen Rudin; J Duffy Mocco
Journal:  Stroke       Date:  2009-01-08       Impact factor: 7.914

9.  Asymmetric vascular stent: feasibility study of a new low-porosity patch-containing stent.

Authors:  Ciprian N Ionita; Ann M Paciorek; Kenneth R Hoffmann; Daniel R Bednarek; Junichi Yamamoto; John Kolega; Elad I Levy; L Nelson Hopkins; Stephen Rudin; J Mocco
Journal:  Stroke       Date:  2008-04-24       Impact factor: 7.914

10.  Computational and experimental investigation of particulate matter deposition in cerebral side aneurysms.

Authors:  Mark Epshtein; Netanel Korin
Journal:  J R Soc Interface       Date:  2020-08-19       Impact factor: 4.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.