Literature DB >> 15972904

Ten-year survival of the MS-30 matt-surfaced cemented stem.

B J Berli1, D Schäfer, E W Morscher.   

Abstract

The Morscher-Spotorno (MS-30) femoral stem is a stainless-steel, straight, three-dimensionally tapered, collarless implant for cemented fixation in total hip replacement. We report the results at ten years of a consecutive series of 124 total hip replacements in 121 patients with the matt-surfaced MS-30 stem and an alumina ceramic head of 28-mm diameter. All the stems were fixed with Palacos bone cement with gentamicin using a modern cementing technique. They were combined with an uncemented, press-fit cup. The mean period of observation was 10.2 years (8.3 to 12.1) and no patient was lost to follow-up. Twenty-seven patients (22%) died with the implant in situ. Nine could only be interviewed by telephone. We included 85 patients with 88 hips in the clinical and radiological follow-up examinations. None of the stems or cups had been revised. The Harris hip score was excellent or good in 97% (85 hips) and moderate in 3% (three hips). Radiologically, six hips (6.8%) had osteolysis adjacent to the stem, mostly in Gruen zone 7. Twenty (22.7%) showed one or more radiolucent lines. Twenty-two stems (25%) had subsided by 2 mm to 5 mm. In these cases two showed osteolysis (9.1%) with subsidence and four without (6.1%). Radiolucent lines were seen in seven with migration (31.8%) and in 13 without (19.7%). No infections and no acetabular osteolysis were observed. The clinical results were excellent with survivorship after ten years of 100% and only a slightly statistically non-significant higher rate of osteolysis and radiolucency in cases of subsidence.

Entities:  

Mesh:

Year:  2005        PMID: 15972904     DOI: 10.1302/0301-620X.87B7.16149

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  9 in total

1.  [The cemented MS-30 stem. A multi-surgeon series of 333 consecutive cases].

Authors:  M Clauss; T Reitzel; M Pritsch; U J Schlegel; R G Bitsch; V Ewerbeck; H Mau; S J Breusch
Journal:  Orthopade       Date:  2006-07       Impact factor: 1.087

2.  Three-dimensional shape optimization of a cemented hip stem and experimental validations.

Authors:  Masaru Higa; Hiromasa Tanino; Ikuya Nishimura; Yoshinori Mitamura; Takeo Matsuno; Hiroshi Ito
Journal:  J Artif Organs       Date:  2014-10-16       Impact factor: 1.731

3.  The effect of a collar and surface finish on cemented femoral stems: a prospective randomised trial of four stem designs.

Authors:  Jonathan Hutt; Alexandra Hazlerigg; Ansari Aneel; Geoffrey Epie; Husam Dabis; Roy Twyman; Andrew Cobb
Journal:  Int Orthop       Date:  2014-01-29       Impact factor: 3.075

4.  Total hip arthroplasty with the MS-30 polished surface cemented stem: a single surgeon consecutive series study at 10 year follow-up.

Authors:  Gavin H O Brigstocke; Philip A Mitchell; John W Rosson
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-11-21

5.  The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design.

Authors:  Gavin J Macpherson; Christian Hank; Michael Schneider; Morag Trayner; Robert Elton; Colin R Howie; Steffen J Breusch
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

6.  Importance of a distal centralizer in experimental malpositioning of cemented stems. A biomechanical study on human femora.

Authors:  Andreas Kusserow; Andreas Ficklscherer; Peter Cornelius Kreuz; Susanne Finze; Wolfram Mittelmeier; Volkmar Jansson; Stefan Milz; Bernd Wegener
Journal:  Arch Med Sci       Date:  2015-12-11       Impact factor: 3.318

7.  Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database.

Authors:  Mika Junnila; Inari Laaksonen; Antti Eskelinen; Pekka Pulkkinen; Leif Ivar Havelin; Ove Furnes; Anne Marie Fenstad; Alma B Pedersen; Søren Overgaard; Johan Kärrholm; Göran Garellick; Henrik Malchau; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2016-08-23       Impact factor: 3.717

8.  Fixation of the cemented stem: clinical relevance of the porosity and thickness of the cement mantle.

Authors:  Philippe Hernigou; Gildasio Daltro; Charles Henri Flouzat Lachaniette; Xavier Roussignol; Martin Mukisi Mukasa; Alexandre Poignard
Journal:  Open Orthop J       Date:  2009-02-12

9.  Total hip replacement in adult patients with severe Kashin-Beck disease of the hip.

Authors:  Xin Tang; Jing Zhu; Zongke Zhou; Bin Shen; Pengde Kang; Fuxing Pei; Jian Li
Journal:  BMC Musculoskelet Disord       Date:  2016-07-15       Impact factor: 2.362

  9 in total