A multicenter, prospective, randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: two-year follow-up results.

James F Zucherman1, Ken Y Hsu, Charles A Hartjen, Thomas F Mehalic, Dante A Implicito, Michael J Martin, Donald R Johnson, Grant A Skidmore, Paul P Vessa, James W Dwyer, Stephen T Puccio, Joseph C Cauthen, Richard M Ozuna.   

Abstract

STUDY
DESIGN: A randomized, controlled, prospective multicenter trial comparing the outcomes of neurogenic intermittent claudication (NIC) patients treated with the interspinous process decompression system (X STOP) with patients treated nonoperatively.
OBJECTIVE: To determine the safety and efficacy of the X STOP interspinous implant. SUMMARY OF BACKGROUND DATA: Patients suffering from NIC secondary to lumbar spinal stenosis have been limited to a choice between nonoperative therapies and decompressive surgical procedures, with or without fusion. The X STOP was developed to provide an alternative therapeutic treatment. METHODS.: 191 patients were treated, 100 in the X STOP group and 91 in the control group. The primary outcomes measure was the Zurich Claudication Questionnaire, a patient-completed, validated instrument for NIC.
RESULTS: At every follow-up visit, X STOP patients had significantly better outcomes in each domain of the Zurich Claudication Questionnaire. At 2 years, the X STOP patients improved by 45.4% over the mean baseline Symptom Severity score compared with 7.4% in the control group; the mean improvement in the Physical Function domain was 44.3% in the X STOP group and -0.4% in the control group. In the X STOP group, 73.1% patients were satisfied with their treatment compared with 35.9% of control patients.
CONCLUSIONS: The X STOP provides a conservative yet effective treatment for patients suffering from lumbar spinal stenosis. In the continuum of treatment options, the X STOP offers an attractive alternative to both conservative care and decompressive surgery.

Entities:  

Mesh:

Year:  2005        PMID: 15959362     DOI: 10.1097/01.brs.0000166618.42749.d1

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  97 in total

1.  The effect of the X-Stop implantation on intervertebral foramen, segmental spinal canal length and disc space in elderly patients with lumbar spinal stenosis.

Authors:  Zongmiao Wan; Shaobai Wang; Michal Kozanek; Qun Xia; Frederick L Mansfield; Guohua Lü; Kirkham B Wood; Guoan Li
Journal:  Eur Spine J       Date:  2011-09-21       Impact factor: 3.134

Review 2.  Role of lumbar interspinous distraction on the neural elements.

Authors:  Alex Alfieri; Roberto Gazzeri; Julian Prell; Christian Scheller; Jens Rachinger; Christian Strauss; Andreas Schwarz
Journal:  Neurosurg Rev       Date:  2012-05-02       Impact factor: 3.042

3.  [Longterm results of the interspinous spacer X-STOP].

Authors:  A Reinhardt; S Hufnagel
Journal:  Orthopade       Date:  2010-06       Impact factor: 1.087

4.  Stabilising effect of dynamic interspinous spacers in degenerative low-grade lumbar instability.

Authors:  Johannes Holinka; Petra Krepler; Michael Matzner; Josef G Grohs
Journal:  Int Orthop       Date:  2010-04-25       Impact factor: 3.075

5.  Computed tomography measurements of the lumbar spinous processes and interspinous space.

Authors:  Rolf Sobottke; Timmo Koy; Marc Röllinghoff; Jan Siewe; Thomas Kreitz; Daniel Müller; Christopher Bangard; Peer Eysel
Journal:  Surg Radiol Anat       Date:  2010-06-15       Impact factor: 1.246

6.  [Treatment of dynamic spinal canal stenosis with an interspinous spacer].

Authors:  Christoph J Siepe; Franziska Heider; Rudolf Beisse; H Michael Mayer; Andreas Korge
Journal:  Oper Orthop Traumatol       Date:  2010-11       Impact factor: 1.154

7.  [Interspinous spacers--technique of Coflex™ implantation].

Authors:  Jens A Richolt; Michael A Rauschmann; Sven Schmidt
Journal:  Oper Orthop Traumatol       Date:  2010-11       Impact factor: 1.154

8.  Spinous process morphology: the effect of ageing through adulthood on spinous process size and relationship to sagittal alignment.

Authors:  Caspar Edward William Aylott; Rupesh Puna; Peter Alexander Robertson; Cameron Walker
Journal:  Eur Spine J       Date:  2011-09-30       Impact factor: 3.134

9.  The effect of design parameters of interspinous implants on kinematics and load bearing: an in vitro study.

Authors:  Christoph Schilling; M Pfeiffer; T M Grupp; W Blömer; A Rohlmann
Journal:  Eur Spine J       Date:  2014-02-19       Impact factor: 3.134

10.  Interspinous spacers compared with decompression or fusion for lumbar stenosis: complications and repeat operations in the Medicare population.

Authors:  Richard A Deyo; Brook I Martin; Alex Ching; Anna N A Tosteson; Jeffrey G Jarvik; William Kreuter; Sohail K Mirza
Journal:  Spine (Phila Pa 1976)       Date:  2013-05-01       Impact factor: 3.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.