Literature DB >> 20424821

[Longterm results of the interspinous spacer X-STOP].

A Reinhardt1, S Hufnagel.   

Abstract

A growing number of interspinous process devices are currently under investigation. No long-term results are currently available for the X-STOP spacer, but short-term and midterm results are promising.The X-STOP spacer is a good alternative to decompression surgery in elderly patients with moderate spinal stenosis without spondylolisthesis or severe osteoporosis. Further prospective controlled randomized studies comparing the X-STOP with decompression surgery must be done to clearly define the indications and to allow prediction of long-term results.

Entities:  

Mesh:

Year:  2010        PMID: 20424821     DOI: 10.1007/s00132-009-1591-7

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  27 in total

1.  Computed tomography findings 4 years after surgical management of lumbar spinal stenosis. No correlation with clinical outcome.

Authors:  A Herno; O Airaksinen; T Saari; M Pitkänen; H Manninen; O Suomalainen
Journal:  Spine (Phila Pa 1976)       Date:  1999-11-01       Impact factor: 3.468

2.  The effects of an interspinous implant on intervertebral disc pressures.

Authors:  Kyle E Swanson; Derek P Lindsey; Ken Y Hsu; James F Zucherman; Scott A Yerby
Journal:  Spine (Phila Pa 1976)       Date:  2003-01-01       Impact factor: 3.468

3.  Appropriate selection of patients with lumbar spinal stenosis for interspinous process decompression with the X STOP device.

Authors:  Carl Lauryssen
Journal:  Neurosurg Focus       Date:  2007-12-15       Impact factor: 4.047

4.  A multicenter, prospective, randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: two-year follow-up results.

Authors:  James F Zucherman; Ken Y Hsu; Charles A Hartjen; Thomas F Mehalic; Dante A Implicito; Michael J Martin; Donald R Johnson; Grant A Skidmore; Paul P Vessa; James W Dwyer; Stephen T Puccio; Joseph C Cauthen; Richard M Ozuna
Journal:  Spine (Phila Pa 1976)       Date:  2005-06-15       Impact factor: 3.468

5.  Quantitative assessment of the lumbar spinal canal by computed tomography.

Authors:  C G Ullrich; E F Binet; M G Sanecki; S A Kieffer
Journal:  Radiology       Date:  1980-01       Impact factor: 11.105

6.  A prospective randomized multi-center study for the treatment of lumbar spinal stenosis with the X STOP interspinous implant: 1-year results.

Authors:  J F Zucherman; K Y Hsu; C A Hartjen; T F Mehalic; D A Implicito; M J Martin; D R Johnson; G A Skidmore; P P Vessa; J W Dwyer; S Puccio; J C Cauthen; R M Ozuna
Journal:  Eur Spine J       Date:  2003-12-19       Impact factor: 3.134

Review 7.  Analysis of complications in patients treated with the X-Stop Interspinous Process Decompression System: proposal for a novel anatomic scoring system for patient selection and review of the literature.

Authors:  Giuseppe M V Barbagallo; Giuseppe Olindo; Leonardo Corbino; Vincenzo Albanese
Journal:  Neurosurgery       Date:  2009-07       Impact factor: 4.654

8.  The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine.

Authors:  Derek P Lindsey; Kyle E Swanson; Paul Fuchs; Ken Y Hsu; James F Zucherman; Scott A Yerby
Journal:  Spine (Phila Pa 1976)       Date:  2003-10-01       Impact factor: 3.468

9.  Clinical Symposium II: Interspinous-based Dynamic Stabilization.

Authors:  Dieter Adelt; Jean Taylor; James Zucherman; Neel Anand
Journal:  SAS J       Date:  2008-09-01

10.  High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis.

Authors:  Olaf J Verhoof; Johannes L Bron; Frits H Wapstra; Barend J van Royen
Journal:  Eur Spine J       Date:  2007-09-11       Impact factor: 3.134

View more
  1 in total

Review 1.  Role of lumbar interspinous distraction on the neural elements.

Authors:  Alex Alfieri; Roberto Gazzeri; Julian Prell; Christian Scheller; Jens Rachinger; Christian Strauss; Andreas Schwarz
Journal:  Neurosurg Rev       Date:  2012-05-02       Impact factor: 3.042

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.