Changes in interface pressures and shear stresses over time on trans-tibial amputee subjects ambulating with prosthetic limbs: comparison of diurnal and six-month differences.

J E Sanders1, S G Zachariah, A K Jacobsen, J R Fergason.   

Abstract

For trans-tibial amputees maintenance over time of a quality fit of the prosthesis to the residual limb is an important clinical challenge. The purpose of this research was to compare diurnal and long-term (5 weeks to 6 months) interface stress changes as well as variance in the change in cross-sectional area down the length of the residual limb. If long-term changes were simply accentuated diurnal fluctuations then this result would suggest similar treatment methods should be used for both conditions. Interface pressures and shear stresses at 13 sites and residual limb shape were measured on eight trans-tibial amputee subjects using patellar-tendon-bearing prostheses. Data were collected at diurnal intervals (within the same day at least 5 h apart) as well as at long-term intervals (5, 10, 15, 20, and 25 weeks apart). Absolute diurnal interface stress changes were not significantly different from those at 5-weeks intervals but were significantly smaller than those at 15, 20, and 25-weeks intervals. Mean interface stress changes increased significantly (p<0.05) for increased session-to-session intervals. Variance of the change in cross-sectional area down the length of the residual limb was significantly smaller for diurnal intervals than for 6-months intervals, indicating that long-term changes were more localized than diurnal changes. These results indicate that long-term changes are not simply accentuated diurnal fluctuations, suggesting that different treatment methods should be used to treat each condition.

Mesh:

Year:  2005        PMID: 15958212     DOI: 10.1016/j.jbiomech.2004.08.008

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  22 in total

1.  How do sock ply changes affect residual-limb fluid volume in people with transtibial amputation?

Authors:  Joan E Sanders; Daniel S Harrison; Katheryn J Allyn; Timothy R Myers; Marcia A Ciol; Elaine C Tsai
Journal:  J Rehabil Res Dev       Date:  2012

Review 2.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

3.  Evaluation of Force Sensing Resistors for the Measurement of Interface Pressures in Lower Limb Prosthetics.

Authors:  Eric Swanson; Ethan Weathersby; John Cagle; Joan E Sanders
Journal:  J Biomech Eng       Date:  2019-04-24       Impact factor: 2.097

4.  Development of Standardized Material Testing Protocols for Prosthetic Liners.

Authors:  John C Cagle; Per G Reinhall; Brian J Hafner; Joan E Sanders
Journal:  J Biomech Eng       Date:  2017-04-01       Impact factor: 2.097

5.  Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Adam K Arabian; Teri G Rosenbaum-Chou; David A Boone
Journal:  J Biomech       Date:  2014-02-14       Impact factor: 2.712

6.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

7.  A Novel Method for Assessing Prosthesis Use and Accommodation Practices of People with Transtibial Amputation.

Authors:  Joan E Sanders; Christian B Redd; Brian G Larsen; Andrew C Vamos; Jacob T Brzostowski; Brian J Hafner; Katheryn J Allyn; Katrina Henrikson; Jake B McLean; Paul Hinrichs
Journal:  J Prosthet Orthot       Date:  2018-10

8.  Does temporary socket removal affect residual limb fluid volume of trans-tibial amputees?

Authors:  Joan E Sanders; Tyler L Hartley; Reid H Phillips; Marcia A Ciol; Brian J Hafner; Katheryn J Allyn; Dan S Harrison
Journal:  Prosthet Orthot Int       Date:  2015-02-20       Impact factor: 1.895

9.  A means to accommodate residual limb movement during optical scanning: a technical note.

Authors:  Joan E Sanders; Gregory S Lee
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-10       Impact factor: 3.802

Review 10.  Considerations for development of sensing and monitoring tools to facilitate treatment and care of persons with lower-limb loss: a review.

Authors:  Brian J Hafner; Joan E Sanders
Journal:  J Rehabil Res Dev       Date:  2014