Literature DB >> 15949751

Spectral analysis of multichannel MRS data.

Niclas Sandgren1, Petre Stoica, Frederick J Frigo, Yngve Selén.   

Abstract

The use of phased-array receive coils is a well-known technique to improve the image quality in magnetic resonance imaging studies of, e.g., the human brain. It is common to incorporate proton (1H) magnetic resonance spectroscopy (MRS) experiments in these studies to quantify key metabolites in a region of interest. Detecting metabolites in vivo is often difficult, requiring extensive scans to achieve signal-to-noise ratios (SNR) that provide suitable diagnostic results. Combining the MR absorption spectra obtained from several receive coils is one possible approach to increase the SNR. Previous literature does not give a clear overview of the wide range of possible approaches that can be used to combine MRS data from multiple detector coils. In this paper, we consider the multicoil MRS approach and introduce several signal processing tools to address the problem from different nonparametric, semiparametric, and parametric perspectives, depending on the amount of available prior knowledge about the data. We present a numerical study of these tools using both simulated 1H MRS data and experimental MRS data acquired from a 3T MR scanner.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15949751     DOI: 10.1016/j.jmr.2005.03.019

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  12 in total

Review 1.  Proton MR spectroscopy of the brain at 3 T: an update.

Authors:  Alfonso Di Costanzo; Francesca Trojsi; Michela Tosetti; Timo Schirmer; Silke M Lechner; Teresa Popolizio; Tommaso Scarabino
Journal:  Eur Radiol       Date:  2007-01-18       Impact factor: 5.315

2.  Optimal phased-array combination for spectroscopy.

Authors:  Mark Bydder; Gavin Hamilton; Takeshi Yokoo; Claude B Sirlin
Journal:  Magn Reson Imaging       Date:  2008-05-16       Impact factor: 2.546

Review 3.  Proton MR spectroscopy in the breast: Technical innovations and clinical applications.

Authors:  Reza Fardanesh; Maria Adele Marino; Daly Avendano; Doris Leithner; Katja Pinker; Sunitha B Thakur
Journal:  J Magn Reson Imaging       Date:  2019-03-07       Impact factor: 4.813

4.  Coil combination methods for multi-channel hyperpolarized 13C imaging data from human studies.

Authors:  Zihan Zhu; Xucheng Zhu; Michael A Ohliger; Shuyu Tang; Peng Cao; Lucas Carvajal; Adam W Autry; Yan Li; John Kurhanewicz; Susan Chang; Rahul Aggarwal; Pamela Munster; Duan Xu; Peder E Z Larson; Daniel B Vigneron; Jeremy W Gordon
Journal:  J Magn Reson       Date:  2019-02-01       Impact factor: 2.229

5.  Integration of 2-hydroxyglutarate-proton magnetic resonance spectroscopy into clinical practice for disease monitoring in isocitrate dehydrogenase-mutant glioma.

Authors:  Macarena I de la Fuente; Robert J Young; Jennifer Rubel; Marc Rosenblum; Jamie Tisnado; Samuel Briggs; Julio Arevalo-Perez; Justin R Cross; Carl Campos; Kimberly Straley; Dongwei Zhu; Chuanhui Dong; Alissa Thomas; Antonio A Omuro; Craig P Nolan; Elena Pentsova; Thomas J Kaley; Jung H Oh; Ralph Noeske; Elizabeth Maher; Changho Choi; Philip H Gutin; Andrei I Holodny; Katharine Yen; Lisa M DeAngelis; Ingo K Mellinghoff; Sunitha B Thakur
Journal:  Neuro Oncol       Date:  2015-12-20       Impact factor: 12.300

6.  Phased-array combination for MR spectroscopic imaging using a water reference.

Authors:  Abas Abdoli; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2015-09-28       Impact factor: 4.668

Review 7.  Proton magnetic resonance spectroscopy: technique for the neuroradiologist.

Authors:  Kim M Cecil
Journal:  Neuroimaging Clin N Am       Date:  2013-01-20       Impact factor: 2.264

8.  Combination of multichannel single-voxel MRS signals using generalized least squares.

Authors:  Li An; Jan Willem van der Veen; Shizhe Li; David M Thomasson; Jun Shen
Journal:  J Magn Reson Imaging       Date:  2012-11-21       Impact factor: 4.813

9.  Effects of apodization smoothing and denoising on spectral fitting.

Authors:  Mohammed Goryawala; Molly Sullivan; Andrew A Maudsley
Journal:  Magn Reson Imaging       Date:  2020-04-22       Impact factor: 2.546

10.  A comparison of coil combination strategies in 3D multi-channel MRSI reconstruction for patients with brain tumors.

Authors:  Maryam Vareth; Janine Lupo; Peder Larson; Sarah Nelson
Journal:  NMR Biomed       Date:  2018-08-31       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.