Literature DB >> 32333950

Effects of apodization smoothing and denoising on spectral fitting.

Mohammed Goryawala1, Molly Sullivan2, Andrew A Maudsley3.   

Abstract

PURPOSE: Visual review of individual spectra in magnetic resonance spectroscopic imaging (MRSI) data benefits from the application of spectral smoothing; however, if this processing step is applied prior to spectral analysis this can impact the accuracy of the quantitation. This study aims to analyze the effect of spectral denoising and apodization smoothing on the quantitation of whole-brain MRSI data obtained at short TE.
METHODS: Short-TE MRSI data obtained at 3 T were analyzed with no spectral smoothing, following (i) Gaussian apodization with values of 1, 2, 4, 6, and 8 Hz, and (ii) denoising using principal component analysis (dnPCA) with 3 different values for the number of retained principal components. The mean lobar white matter estimates for four metabolites, signal-to-noise ratio (SNR), spectral linewidth, and confidence intervals were compared to data reconstructed using no smoothing. Additionally, a voxel-wise comparison for N-acetylaspartate quantitation with different smoothing schemes was performed.
RESULTS: Significant pairwise differences were seen for all Gaussian smoothing methods as compared to no smoothing (p<0.001) in linewidth and metabolite estimates, whereas dnPCA methods showing no statistically significant differences in these measures. Confidence intervals decreased, and SNR increased with increasing levels of apodization smoothing or dnPCA denoising.
CONCLUSION: Mild Gaussian apodization (≤2 Hz at 3 T) can be applied with minimal (1%) errors in quantitation; however, smoothing values greater than that can significantly affect metabolite quantification. In contrast, mild to moderate dnPCA based denoising provides quantitative results that are consistent with the analysis of unsmoothed data and this method is recommended for spectral denoising.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Denoising; MRSI; Metabolite quantification; PCA; Smoothing; Spectral fitting

Mesh:

Substances:

Year:  2020        PMID: 32333950      PMCID: PMC7311312          DOI: 10.1016/j.mri.2020.04.013

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  19 in total

1.  Factors affecting the quantification of short echo in-vivo 1H MR spectra: prior knowledge, peak elimination, and filtering.

Authors:  R Bartha; D J Drost; P C Williamson
Journal:  NMR Biomed       Date:  1999-06       Impact factor: 4.044

2.  Confidence images for MR spectroscopic imaging.

Authors:  K Young; D Khetselius; B J Soher; A A Maudsley
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

Review 3.  NMR spectral quantitation by principal component analysis.

Authors:  R Stoyanova; T R Brown
Journal:  NMR Biomed       Date:  2001-06       Impact factor: 4.044

Review 4.  MR spectroscopy quantitation: a review of time-domain methods.

Authors:  L Vanhamme; T Sundin; P V Hecke; S V Huffel
Journal:  NMR Biomed       Date:  2001-06       Impact factor: 4.044

5.  Comprehensive processing, display and analysis for in vivo MR spectroscopic imaging.

Authors:  A A Maudsley; A Darkazanli; J R Alger; L O Hall; N Schuff; C Studholme; Y Yu; A Ebel; A Frew; D Goldgof; Y Gu; R Pagare; F Rousseau; K Sivasankaran; B J Soher; P Weber; K Young; X Zhu
Journal:  NMR Biomed       Date:  2006-06       Impact factor: 4.044

6.  Regional distributions of brain glutamate and glutamine in normal subjects.

Authors:  Mohammed Z Goryawala; Sulaiman Sheriff; Andrew A Maudsley
Journal:  NMR Biomed       Date:  2016-06-28       Impact factor: 4.044

Review 7.  MRS signal quantitation: a review of time- and frequency-domain methods.

Authors:  Jean-Baptiste Poullet; Diana M Sima; Sabine Van Huffel
Journal:  J Magn Reson       Date:  2008-09-11       Impact factor: 2.229

8.  Automated spectral analysis III: application to in vivo proton MR spectroscopy and spectroscopic imaging.

Authors:  B J Soher; K Young; V Govindaraju; A A Maudsley
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

9.  Denoising of MR spectroscopic imaging data using statistical selection of principal components.

Authors:  Abas Abdoli; Radka Stoyanova; Andrew A Maudsley
Journal:  MAGMA       Date:  2016-06-03       Impact factor: 2.310

10.  Mapping of brain metabolite distributions by volumetric proton MR spectroscopic imaging (MRSI).

Authors:  A A Maudsley; C Domenig; V Govind; A Darkazanli; C Studholme; K Arheart; C Bloomer
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

View more
  1 in total

1.  PCA denoising and Wiener deconvolution of 31 P 3D CSI data to enhance effective SNR and improve point spread function.

Authors:  Martijn Froeling; Jeanine J Prompers; Dennis W J Klomp; Tijl A van der Velden
Journal:  Magn Reson Med       Date:  2021-02-01       Impact factor: 4.668

  1 in total